Management of extensor tendon injuries concerning distal radius fractures

被引:1
作者
Bhardwaj, Praveen [1 ,3 ]
Varadharajan, Vigneswaran [1 ]
Jain, Darshan [2 ]
Sabapathy, S. Raja [1 ]
机构
[1] Ganga Med Ctr & Hosp Pvt Lt, Dept Hand & Microsurg, Coimbatore, India
[2] Ramaiah Mem Hosp, Dept Orthopaed, Bengaluru, India
[3] Ganga Med Ctr & Hosp, Dept Hand & Microsurg, 313 Mettupalayam Rd, Coimbatore 641043, Tamil Nadu, India
关键词
Distal radius; Extensor tendon; Extensor pollicis longus; POLLICIS LONGUS TENDON; DELAYED RUPTURE; PLATE FIXATION; INDICIS;
D O I
10.1016/j.jor.2023.11.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Rupture of the extensor tendons secondary to fractures involving the distal radius is a well-recognized rare complication. In patients with implants particularly, there exists a tendency for attributing the implant as a cause for the tendon rupture. We retrospectively studied the patients with extensor tendon injuries related to distal radius fractures, analyzed the factors leading to the rupture, suggest few preventive measures and describe the management strategy of these ruptures. Materials and methods: 21 patients who were treated for extensor tendon rupture following distal radius fractures in the period of 2014-2022 were retrospectively analyzed. 19 patients had been managed with surgery and two patients conservatively for the distal radius fracture. The time interval between the fracture fixation and tendon rupture, the time interval between tendon rupture and presentation, the extensor tendons injured and the position of the impinging screws or bony spur in relation to the extensor compartments, necessity for implant removal and modality of tendon reconstruction were studied in these patients. Results: Extensor pollicis longus was found to be ruptured in all the patients except one patient with Extensor indicis proprius rupture alone. The time interval between the fracture fixation and tendon rupture averaged at 32.5 months. End to end repair of the ruptured tendons was never possible even in patients who presented earlier. 10 patients underwent intertendinous bridge grafting and 11 patients underwent tendon transfer. All the patients achieved full extension of thumb with no donor deficit. Conclusion: Distal radius fracture related extensor tendon injuries pose a technical challenge to the surgeon and concern to the patient in the form of recurring surgeries. However, with immediate presentation to the surgeon and their use of appropriately designed management algorithm, these patients could be immensely satisfied with the outcome.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 28 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Two potential causes of EPL rupture after distal radius volar plate fixation [J].
Benson, Eric C. ;
DeCarvalho, Alex ;
Mikola, Elizabeth A. ;
Veitch, John M. ;
Moneim, Moheb S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :218-222
[4]   Concomitant Rupture of Extensor Pollicis Longus and Index Extensor Tendons following Distal Radius Plating-Report of Two Cases and Their Clinical Implication for Tendon Transfer Surgery [J].
Bhardwaj, Praveen ;
Varadharajan, Vigneswaran ;
Sabapathy, S. Raja .
INDIAN JOURNAL OF PLASTIC SURGERY, 2020, 53 (03) :435-438
[5]   "Island-shape" Fractures of Lister's tubercle have an increased risk of delayed extensor pollicis longus rupture in distal radial fractures After surgical treatment by volar locking plate [J].
Cha, Soo Min ;
Shin, Hyun Dae ;
Lee, Soong Hyun .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (10) :1816-1821
[6]   RUPTURE OF THE EXTENSOR POLLICIS LONGUS TENDON AFTER FRACTURE OF THE LOWER END OF THE RADIUS - CLINICAL AND MICRO-ANGIOGRAPHIC STUDY [J].
ENGKVIST, O ;
LUNDBORG, G .
HAND, 1979, 11 (01) :76-86
[7]   DELAYED RUPTURE OF EXTENSOR DIGITORUM COMMUNIS TENDON FOLLOWING VOLAR PLATING OF DISTAL RADIUS FRACTURE [J].
Hattori, Yasunori ;
Doi, Kazuteru ;
Sakamoto, Soutetsu ;
Yukata, Kiminori .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2008, 13 (03) :183-185
[8]   RUPTURE OF THE EXTENSOR POLLICIS LONGUS TENDON IN UNDISPLACED COLLES TYPE OF FRACTURE [J].
HELAL, B ;
CHEN, SC ;
IWEGBU, G .
HAND, 1982, 14 (01) :41-47
[9]   CLINICAL AND MICROANGIOGRAPHIC STUDIES ON RUPTURE OF THE EPL TENDON AFTER DISTAL RADIAL FRACTURES [J].
HIRASAWA, Y ;
KATSUMI, Y ;
AKIYOSHI, T ;
TAMAI, K ;
TOKIOKA, T .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1990, 15B (01) :51-57
[10]   DELAYED RUPTURE OF THE THUMB EXTENSOR TENDON - A 5-YEAR STUDY OF 18 CONSECUTIVE CASES [J].
HOVE, LM .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :199-203