Use of point-of-care haemoglobin tests to diagnose childhood anaemia in low- and middle-income countries: A systematic review

被引:6
作者
Brehm, Rebecca [1 ]
South, Annabelle [2 ]
George, Elizabeth C. [2 ]
机构
[1] UCL, Inst Clin Trials & Methodol, London, England
[2] UCL, Med Res Council Clin Trials Unit MRC CTU, London, England
基金
英国医学研究理事会;
关键词
anaemia; children; haemoglobin; low- and middle-income countries; point-of-care testing; systematic review; SICKLE-CELL-DISEASE; AFRICAN CHILDREN; HEALTH-CARE; ANTIMALARIAL TREATMENT; COLOR SCALE; BLOOD; TRANSFUSION; PERFORMANCE; POPULATIONS; INFECTIONS;
D O I
10.1111/tmi.13957
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: Anaemia is a major cause of mortality and transfusion in children in low- and middle-income countries (LMICs); however, current diagnostics are slow, costly and frequently unavailable. Point-of-care haemoglobin tests (POC(Hb)Ts) could improve patient outcomes and use of resources by providing rapid and affordable results. We systematically reviewed the literature to investigate what, where and how POC(Hb)Ts are being used by health facilities in LMICs to diagnose childhood anaemia, and to explore challenges to their use.Methods: We searched a total of nine databases and trial registries up to 10 June 2022 using the concepts: anaemia, POC(Hb)T, LMIC and clinical setting. Adults >= 21 years and literature published >15 years ago were excluded. A single reviewer conducted screening, data extraction and quality assessment (of diagnostic studies) using QUADAS-2. Outcomes including POC(Hb)T used, location, setting, challenges and diagnostic accuracy were synthesised.Results: Of 626 records screened, 41 studies were included. Evidence is available on the use of 15 POC(Hb)Ts in hospitals (n = 28, 68%), health centres (n = 9, 22%) and clinics/units (n = 10, 24%) across 16 LMICs. HemoCue (HemoCue AB, angelholm, Sweden) was the most used test (n = 31, 76%). Key challenges reported were overestimation of haemoglobin concentration, clinically unacceptable limits of agreement, errors/difficulty in sampling, environmental factors, cost, inter-observer variability and supply of consumables. Five POC(Hb)Ts (33%) could not detect haemoglobin levels below 4.5 g/dL. Diagnostic accuracy varied, with sensitivity and specificity to detect anaemia ranging from 24.2% to 92.2% and 70% to 96.7%, respectively.Conclusions: POC(Hb)Ts have been successfully utilised in health facilities in LMICs to diagnose childhood anaemia. However, limited evidence is available, and challenges exist that must be addressed before wider implementation. Further research is required to confirm accuracy, clinical benefits and cost-effectiveness.
引用
收藏
页码:73 / 87
页数:15
相关论文
共 90 条
[1]   Validity of Point-of-Care Testing Mission Plus in Detecting Anemia [J].
Ahmad, Noor Ani ;
Awaluddin, S. Maria ;
Samad, Rahama ;
Kasim, Noraida Mohd ;
Yusof, Muslimah ;
Abd Razak, Mohd Aznuddin ;
Ying, Chan Ying ;
Sahril, Norhafizah .
INTERNATIONAL JOURNAL OF BIOMEDICINE, 2015, 5 (02) :91-94
[2]   Magnitude of anemia and associated factors among children aged 6-59 months at Debre Markos referral hospital, Northwest Ethiopia: a hospital-based cross-sectional study [J].
Alamneh, Yoseph Merkeb ;
Akalu, Tadesse Yirga ;
Shiferaw, Abtie Abebaw ;
Atnaf, Aytenew .
ITALIAN JOURNAL OF PEDIATRICS, 2021, 47 (01)
[3]   Evaluation of the diagnostic accuracy of the Haemoglobin Colour Scale to detect anaemia in young children attending primary healthcare clinics in Zanzibar [J].
Aldridge, Catherine ;
Foster, Hamish M. E. ;
Albonico, Marco ;
Ame, Shaali M. ;
Montresor, Antonio .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2012, 17 (04) :423-429
[4]   Emerging point-of-care technologies for anemia detection [J].
An, Ran ;
Huang, Yuning ;
Man, Yuncheng ;
Valentine, Russell W. ;
Kucukal, Erdem ;
Goreke, Utku ;
Sekyonda, Zoe ;
Piccone, Connie ;
Owusu-Ansah, Amma ;
Ahuja, Sanjay ;
Little, Jane A. ;
Gurkan, Umut A. .
LAB ON A CHIP, 2021, 21 (10) :1843-1865
[5]  
[Anonymous], TRIAL 2 POINT CARE D
[6]  
[Anonymous], 2014, March 2014 supplement to the 2013 consolidated guidelines on the use of antiretroviral drugs for treating and preventing HIV infections: Recommendations for a public health approach
[7]   Status of hospital-based blood transfusion services in low-income and middle-income countries: a cross-sectional international survey [J].
Barnes, Linda S. ;
Stanley, Jean ;
Bloch, Evan M. ;
Pagano, Monica B. ;
Ipe, Tina S. ;
Eichbaum, Quentin ;
Wendel, Silvano ;
Indrikovs, Alexander ;
Cai, Wei ;
Delaney, Meghan .
BMJ OPEN, 2022, 12 (02)
[8]   Two Strategies for the Delivery of IPTc in an Area of Seasonal Malaria Transmission in The Gambia: A Randomised Controlled Trial [J].
Bojang, Kalifa A. ;
Akor, Francis ;
Conteh, Lesong ;
Webb, Emily ;
Bittaye, Ousman ;
Conway, David J. ;
Jasseh, Momodou ;
Wiseman, Virginia ;
Milligan, Paul J. ;
Greenwood, Brian .
PLOS MEDICINE, 2011, 8 (02)
[9]  
Bond M, 2014, 2014 IEEE Healthcare Innovation Conference (HIC), P267, DOI 10.1109/HIC.2014.7038926
[10]  
Calis JCJ, 2016, MALAWI MED J, V28, P99