Adapted Galvanostatic Charge Method for cell-individual in-situ characterization of PEM fuel cell stacks and systems☆

被引:3
作者
Moeller, Leonie [1 ]
Rink, Matthias [1 ]
Kemmer, Helerson [1 ]
von Unwerth, Thomas [2 ]
机构
[1] Robert Bosch GmbH, Robert-Bosch-Campus 1, D-71272 Renningen, Baden Wurttembe, Germany
[2] TU Chemnitz, Inst Automot Res, Reichenhainer Str 70, D-09126 Chemnitz, Sachsen, Germany
关键词
PEM; Hydrogen; Galvanostatic Charge Method; Cell-individual; Onboard; Diagnosis; DIAGNOSTIC-TOOL; SURFACE-AREA;
D O I
10.1016/j.jpowsour.2023.233606
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Increasingly challenging lifetime requirements for automotive Polymer-Electrolyte-Membrane (PEM) fuel cells call for onboard characterization methods to enable state-of-health (SOH) adaptive operation strategies. In this work, an adapted Galvanostatic Charge Method (GCM) is presented, that allows for cell-individual electrochemical characterization without nitrogen flush, making it system-and potentially onboard-compatible. Key innovation is to utilize the system's standard shutdown procedure, i.e. oxygen depletion with closed air valves, to create an inert atmosphere in the cathode volume in which the characterization takes place. The electrochemical processes triggered during the characterization with GCM are now embedded in a closed -volume-problem instead of a steady-flow-environment. This causes the hydrogen concentration difference between anode and cathode to be dynamic instead of constant during the characterization. In this work, a 0D-simulation model of the closed-volume-problem and complementary measurements on a system testbench are presented. Additionally, a novel model-based evaluation method is introduced which extracts the SOH -indicators electrochemical active surface area (ECSA), double layer capacity, hydrogen permeability of the membrane and short circuit resistance from the measurements by fitting simulated to measured voltage curves. The simulation model is thoroughly analyzed and a systematic error, evoked by the fluidic coupling of the individual cells, is found to influence the results obtained for membrane permeability. The influence of different initial conditions (among them initial hydrogen concentration) on the evaluation results is experimentally investigated and found to have no significant influence. For further studies, improvement potential was found in modeling, measurement procedure and evaluation method.
引用
收藏
页数:11
相关论文
共 15 条
[1]   In situ measurement of active catalyst surface area in fuel cell stacks [J].
Brightman, E. ;
Hinds, G. ;
O'Malley, R. .
JOURNAL OF POWER SOURCES, 2013, 242 :244-254
[2]   Differential capacity plot as a tool for determination of electroactive surface area within a PEMFC stack [J].
Chatillon, Yohann ;
Bonnet, Caroline ;
Lapicque, Francois .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2013, 43 (10) :1017-1026
[3]   Prescriptive Lifetime Management for PEM fuel cell systems in transportation applications, Part I: State of the art and conceptual design [J].
Dirkes, Steffen ;
Leidig, Julian ;
Fisch, Philipp ;
Pischinger, Stefan .
ENERGY CONVERSION AND MANAGEMENT, 2023, 277
[4]   Improved electrochemical in-situ characterization of polymer electrolyte membrane fuel cell stacks [J].
Hartung, I. ;
Kirsch, S. ;
Zihrul, P. ;
Mueller, O. ;
von Unwerth, T. .
JOURNAL OF POWER SOURCES, 2016, 307 :280-288
[5]   Comprehensive analysis of galvanostatic charge method for fuel cell degradation diagnosis [J].
Hu, Zunyan ;
Xu, Liangfei ;
Huang, Yiyuan ;
Li, Jianqiu ;
Ouyang, Minggao ;
Du, Xiaoli ;
Jiang, Hongliang .
APPLIED ENERGY, 2018, 212 :1321-1332
[6]   Development of a galvanostatic analysis technique as an in-situ diagnostic tool for PEMFC single cells and stacks [J].
Lee, Kug-Seung ;
Lee, Byung-Seok ;
Yoo, Sung Jong ;
Kim, Soo-Kil ;
Hwang, Seung Jun ;
Kim, Hyung-Juhn ;
Cho, EunAe ;
Henkensmeier, Dirk ;
Yun, Jeong Woo ;
Nam, Suk Woo ;
Lim, Tae-Hoon ;
Jang, Jong Hyun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (07) :5891-5900
[7]   Improved methods to measure hydrogen crossover current in proton exchange membrane fuel cell [J].
Pei, Pucheng ;
Wu, Ziyao ;
Li, Yuehua ;
Jia, Xiaoning ;
Chen, Dongfang ;
Huang, Shangwei .
APPLIED ENERGY, 2018, 215 :338-347
[8]   Use of galvanostatic charge method as a membrane electrode assembly diagnostic tool in a fuel cell stack [J].
Pei, Pucheng ;
Xu, Huachi ;
Zeng, Xia ;
Zha, Hongshan ;
Song, Mancun .
JOURNAL OF POWER SOURCES, 2014, 245 :175-182
[9]   Rapid synchronous state-of-health diagnosis of membrane electrode assemblies in fuel cell stacks [J].
Ren, Peng ;
Meng, Yining ;
Pei, Pucheng ;
Fu, Xi ;
Chen, Dongfang ;
Li, Yuehua ;
Zhu, Zijing ;
Zhang, Lu ;
Wang, Mingkai .
APPLIED ENERGY, 2023, 330
[10]   Micro-current excitation for efficient diagnosis of membrane electrode assemblies in fuel cell stacks: Error analysis and method optimization [J].
Ren, Peng ;
Pei, Pucheng ;
Chen, Dongfang ;
Li, Yuehua ;
Wang, He ;
Fu, Xi ;
Zhang, Lu ;
Wang, Mingkai ;
Song, Xin .
ENERGY CONVERSION AND MANAGEMENT, 2022, 258