Submillimeter Sized 2D Electrothermal Optical Fiber Scanner

被引:6
作者
Kaur, Mandeep [1 ]
Menon, Carlo [1 ,2 ]
机构
[1] Simon Fraser Univ, Sch Mechatron Syst Engn & Engn Sci, MENRVA Res Grp, Surrey, BC V3T 0A3, Canada
[2] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, CH-8092 Zurich, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
optical scanner; electrothermal actuator; cantilever beam; resonance; MEMS; imaging; WIDE-FIELD; ENDOSCOPE; OPTIMIZATION; CATHETER; RESOLUTION; DESIGN;
D O I
10.3390/s23010404
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical scanners are used frequently in medical imaging units to examine and diagnose cancers, assist with surgeries, and detect lesions and malignancies. The continuous growth in optics along with the use of optical fibers enables fabrication of imaging devices as small as a few millimeters in diameter. Most forward viewing endoscopic scanners contain an optical fiber acting as cantilever which is vibrated at resonance. In many cases, more than one actuating element is used to vibrate the optical fiber in two directions giving a 2D scan. In this paper, it is proposed to excite the cantilever fiber using a single actuator and scan a 2D region from its vibrating tip. An electrothermal actuator is optimized to provide a bidirectional (horizontal and vertical) displacement to the cantilever fiber placed on it. A periodic current, having a frequency equal to the resonant frequency of cantilever fiber, was passed through the actuator. The continuous expansion and contraction of the actuator enabled the free end of fiber to vibrate in a circle like pattern. A small change in the actuation frequency permitted the scanning of the area inside the circle.
引用
收藏
页数:20
相关论文
共 37 条
[31]   Single fiber flexible endoscope: general design for small size, high resolution, and wide field of view. [J].
Seibel, EJ ;
Smithwick, QYJ ;
Brown, CM ;
Reinhall, PG .
BIOMONITORING AND ENDOSCOPY TECHNOLOGIES, 2001, 4158 :29-39
[32]   1.65 mm diameter forward-viewing confocal endomicroscopic catheter using a flip-chip bonded electrothermal MEMS fiber scanner [J].
Seo, Yeong-Hyeon ;
Hwang, Kyungmin ;
Jeong, Ki-Hun .
OPTICS EXPRESS, 2018, 26 (04) :4780-+
[33]   Design and Fabrication of a 2-Axis Electrothermal MEMS Micro-Scanner for Optical Coherence Tomography [J].
Tanguy, Quentin A. A. ;
Bargiel, Sylwester ;
Xie, Huikai ;
Passilly, Nicolas ;
Barthes, Magali ;
Gaiffe, Olivier ;
Rutkowski, Jaroslaw ;
Lutz, Philippe ;
Gorecki, Christophe .
MICROMACHINES, 2017, 8 (05)
[34]  
Wu L., 2006, P 5 INT C PHOTONICS
[35]   Modeling of two-hot-arm horizontal thermal actuator [J].
Yan, D ;
Khajepour, A ;
Mansour, R .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (02) :312-322
[36]   A Single-Fiber Endoscope Scanner Probe Utilizing Two-Degrees-of-Freedom (2DOF) High-Order Resonance to Realize Larger Scanning Angle [J].
Yao, Jinyuan ;
Yang, Zhuoqing ;
Peng, Tao ;
Sun, Bin ;
Zhang, Haodong ;
Zhao, Mengyuan ;
Dai, Bo ;
Liu, Hua ;
Ding, Guifu ;
Sawada, Renshi .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2019, 9 (12) :2332-2340
[37]   Electrostatic micromachine scanning mirror for optical coherence tomography [J].
Zara, JM ;
Yazdanfar, S ;
Rao, KD ;
Izatt, JA ;
Smith, SW .
OPTICS LETTERS, 2003, 28 (08) :628-630