Phase change materials for portable isothermal incubators as a solution to shorten effective analysis times in microbiological quality control of drinking water

被引:0
作者
Codony, F. [1 ]
Dangla, C. [1 ]
Ventola, L. [2 ]
Sabate, N. [1 ]
机构
[1] Lab Aigues Mataro, Carrer Hellade 17-19, Barcelona 08304, Spain
[2] LVM Thermal Solut, Carretera Vic 20 Nau 8, Barcelona 17176, Spain
关键词
Isothermal incubation; Field analysis; Water microbiology; E; coli; ESCHERICHIA-COLI;
D O I
10.1007/s10661-023-11742-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The microbiological quality control of water for human consumption of parameters relevant as E.coli and total coliforms does not start on the field despite the existence of test methods that could make it possible. One of the things that makes this difficult is the possibility of initiating an effective and reliable incubation at the sampling site. The appearance of isothermal media with phase change materials solves this limitation. When phase change materials combine a relatively high melting heat with a suitable melting temperature adapted to the application temperature, they become excellent materials for thermal protection and for thermal energy storage. Starting the test at the same sampling point means that the effective times to obtain a result are shorter, improving water quality control. On the other hand, operationally, it also allows longer sampling routes. Both aspects are essential for managers responsible for controlling water quality for human consumption. In this work, the evidence that demonstrates the feasibility of this approach is presented.
引用
收藏
页数:6
相关论文
共 9 条
[1]  
[Anonymous], 2017, ISO/IEC/IEEE24765:2017(E), P1, DOI [DOI 10.1109/IEEESTD.2017.8016712, 10.1109/IEEESTD, DOI 10.1109/IEEESTD]
[2]   MicroMI: A portable microbiological mobile incubator that uses inexpensive lithium power banks for field microbiology [J].
Diep, Tai The ;
Bizley, Samuel ;
Ray, Partha Pratim ;
Edwards, Alexander Daniel .
HARDWAREX, 2021, 10
[3]  
International Organization for Standardization, 2012, ISO Standard No. 9308-02
[4]  
International Organization for Standardization, 2006, ISO Standard No. 19458)
[5]  
ISO, 2018, 8199 ISO
[6]   Phase change materials for thermal energy storage [J].
Pielichowska, Kinga ;
Pielichowski, Krzysztof .
PROGRESS IN MATERIALS SCIENCE, 2014, 65 :67-123
[7]   Assessment of the effects of holding time and temperature on Escherichia coli densities in surface water samples [J].
Pope, ML ;
Bussen, M ;
Feige, MA ;
Shadix, L ;
Gonder, S ;
Rodgers, C ;
Chambers, Y ;
Pulz, J ;
Miller, K ;
Connell, K ;
Standridge, J .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2003, 69 (10) :6201-6207
[8]   Microbial indicators, pathogens and methods for their monitoring in water environment [J].
Saxena, Gaurav ;
Bharagava, Ram Naresh ;
Kaithwas, Gaurav ;
Raj, Abhay .
JOURNAL OF WATER AND HEALTH, 2015, 13 (02) :319-339
[9]   Detection of viable Escherichia coli in environmental water using combined propidium monoazide staining and quantitative PCR [J].
Yuan, Yuan ;
Zheng, Guolu ;
Lin, Mengshi ;
Mustapha, Azlin .
WATER RESEARCH, 2018, 145 :398-407