Coronary Perfusion After Valve-in-Valve Transcatheter Aortic Valve Implantation in Small Aortic Root: In Vitro Experimental Assessment

被引:1
作者
Jaworek, Michal [1 ,2 ]
Gelpi, Guido [3 ]
Perico, Francesca [1 ,2 ]
Romagnoni, Claudia [3 ]
Tasca, Giordano [4 ]
Salurso, Eleonora [1 ,2 ]
Contino, Monica [2 ,3 ]
Redaelli, Alberto [1 ,2 ]
Fiore, Gianfranco Beniamino [1 ,2 ]
Vismara, Riccardo [1 ,2 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Via Golgi 39, I-20133 Milan, Italy
[2] ForcardioLab Fdn Ric Cardiochirurg ONLUS, Milan, Italy
[3] Fdn IRCCS Ca Grande Osped Maggiore Policlin, Cardiac Surg Unit, Milan, Italy
[4] King Saud Med City, Heart Hlth Ctr, Cardiac Surg Dept, Riyadh, Saudi Arabia
关键词
Valve-in-valve; TAVR; TAVI; Aortic valve; Coronary flow; Coronary obstruction; Aortic root; In vitro; Bench; TO-EDGE TREATMENT; TRICUSPID REGURGITATION; REPLACEMENT; FLOW; OBSTRUCTION; SYSTEM;
D O I
10.1007/s12265-023-10364-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to quantify the coronary perfusion after VIV-TAVI in a high-risk aortic root anatomy. 3D printed models of small aortic root were used to simulate the implantation of a TAVI prosthesis (Portico 23) into surgical prostheses ( Trifecta 19 and 21). The aortic root models were tested in a pulsatile in vitro bench setup with a coronary perfusion simulator. The tests were performed at baseline and post-VIV-TAVI procedure in aligned and misaligned commissural configurations under simulated hemodynamic rest and exercise conditions. The experimental design provided highly controllable and repeatable flow and pressure conditions. The left and right coronary mean flow did not differ significantly at pre- and post-VIV-TAVI procedure in any tested configurations. The commissural misalignment did not induce any significant alterations to the coronary flow.
引用
收藏
页码:956 / 967
页数:12
相关论文
共 30 条
[1]  
Adamo Marianna, 2017, EuroIntervention, V13, pe1032, DOI 10.4244/EIJ-D-17-00193
[2]   Hemodynamic effects of aortic valve and heart rate on coronary perfusion [J].
Avrahami, Idit ;
Even-Chen, Barak ;
Liberzon, Alex .
CLINICAL BIOMECHANICS, 2020, 78
[3]   Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: An in vitro study [J].
Azadani, Ali N. ;
Reardon, Michael ;
Simonato, Matheus ;
Aldea, Gabriel ;
Nickenig, Georg ;
Kornowski, Ran ;
Dvir, Danny .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (06) :1303-U1477
[4]   Hydrodynamic comparison of biological prostheses during progressive valve calcification in a simulated exercise situation. An in vitro study [J].
Bakhtiary, Farhad ;
Dzemali, Omer ;
Steinseiffer, Ulrich ;
Schmitz, Christof ;
Glasmacher, Birgit ;
Moritz, Anton ;
Kleine, Peter .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (05) :960-963
[5]   Coronary Obstruction in Transcatheter Aortic Valve-in-Valve Implantation Preprocedural Evaluation, Device Selection, Protection, and Treatment [J].
Dvir, Danny ;
Leipsic, Jonathon ;
Blanke, Philipp ;
Ribeiro, Henrique B. ;
Kornowski, Ran ;
Pichard, Augusto ;
Rodes-Cabau, Joseph ;
Wood, David A. ;
Stub, Dion ;
Ben-Dor, Itsik ;
Maluenda, Gabriel ;
Makkar, Raj R. ;
Webb, John G. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (01)
[6]   Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves Results From the Global Valve-in-Valve Registry [J].
Dvir, Danny ;
Webb, John ;
Brecker, Stephen ;
Bleiziffer, Sabine ;
Hildick-Smith, David ;
Colombo, Antonio ;
Descoutures, Fleur ;
Hengstenberg, Christian ;
Moat, Neil E. ;
Bekeredjian, Raffi ;
Napodano, Massimo ;
Testa, Luca ;
Lefevre, Thierry ;
Guetta, Victor ;
Nissen, Henrik ;
Hernandez, Jose-Maria ;
Roy, David ;
Teles, Rui C. ;
Segev, Amit ;
Dumonteil, Nicolas ;
Fiorina, Claudia ;
Gotzmann, Michael ;
Tchetche, Didier ;
Abdel-Wahab, Mohamed ;
De Marco, Federico ;
Baumbach, Andreas ;
Laborde, Jean-Claude ;
Kornowski, Ran .
CIRCULATION, 2012, 126 (19) :2335-+
[7]   Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling [J].
Fuchs, Andreas ;
Kofoed, Klaus F. ;
Yoon, Sung-Han ;
Schaffner, Yannick ;
Bieliauskas, Gintautas ;
Thyregod, Hans Gustav ;
Makkar, Raj ;
Sondergaard, Lars ;
De Backer, Ole ;
Bapat, Vinayak .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (17) :1733-1743
[8]   Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Hatoum, Hoda ;
Gooden, Shelley C. M. ;
Sathananthan, Janarthanan ;
Sellers, Stephanie ;
Kutting, Maximilian ;
Marx, Philipp ;
Lilly, Scott M. ;
Ihdayhid, Abdul R. ;
Thourani, Vinod H. ;
Dasi, Lakshmi Prasad .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) :2657-2666
[9]   A case study on implantation strategies to mitigate coronary obstruction in a patient receiving transcatheter aortic valve replacement [J].
Hatoum, Hoda ;
Lilly, Scott M. ;
Crestanello, Juan ;
Dasi, Lakshmi Prasad .
JOURNAL OF BIOMECHANICS, 2019, 89 :115-118
[10]   Delayed Coronary Obstruction After Transcatheter Aortic Valve Replacement [J].
Jabbour, Richard J. ;
Tanaka, Akihito ;
Finkelstein, Ariel ;
Mack, Michael ;
Tamburino, Corrado ;
Van Mieghem, Nicolas ;
de Backer, Ole ;
Testa, Luca ;
Gatto, Pamela ;
Purita, Paola ;
Rahhab, Zouhair ;
Veulemans, Verena ;
Stundl, Anja ;
Barbanti, Marco ;
Nerla, Roberto ;
Sinning, Jan Malte ;
Dvir, Danny ;
Tarantini, Giuseppe ;
Szerlip, Molly ;
Scholtz, Werner ;
Scholtz, Smita ;
Tchetche, Didier ;
Castriota, Fausto ;
Butter, Christian ;
Sondergaard, Lars ;
Abdel-Wahab, Mohamed ;
Sievert, Horst ;
Alfieri, Ottavio ;
Webb, John ;
Rodes-Cabau, Josep ;
Colombo, Antonio ;
Latib, Azeem .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (14) :1513-1524