Dual-frequency resonant coil design for low-γ X-nuclear and proton magnetic resonance imaging at ultrahigh fields

被引:3
作者
Zhang, Guangle [1 ]
Zhu, Wei [1 ]
Li, Xin [1 ]
Zhu, Xiao-Hong [1 ]
Chen, Wei [1 ,2 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res CMRR, Dept Radiol, Minneapolis, MN USA
[2] Univ Minnesota, Ctr Magnet Resonance Res CMRR, Dept Radiol, 2021 6th St South East, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
chemical shift imaging; dual-frequency resonant coil design; low-gamma X-nuclear MRS imaging; proton MRI; ultrahigh fields; RF SURFACE COIL; IN-VIVO; P-31; MRS; BIRDCAGE COIL; TRAP DESIGN; VOLUME COIL; HUMAN BRAIN; NMR; H-1; SPECTROSCOPY;
D O I
10.1002/nbm.4930
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Low-? X-nuclear MRS and imaging have played a key role in studying metabolism and physiopathology, especially at ultrahigh fields. We design and demonstrate a novel and simple dual-frequency RF resonant coil that can operate at both low-? X-nuclear and proton frequencies. The dual-frequency resonant coil comprises an LC coil loop and a tuning-matching circuit bridged by two short wires of the desired length to generate two resonant modes: one for proton MRI and the other for low-? X-nuclear MRS imaging with a large difference in their Larmor frequencies at ultrahigh fields. The coil parameters for the desired coil size and resonant frequencies can be determined via numerical simulations based on LC circuit theory. We designed, constructed, and evaluated several prototype surface coils and quadrature array coils for H-1 and H-2 or O-17 imaging, with small-sized (diameter <= 5 cm) coils evaluated using a 16.4 T animal scanner, and a large-sized (15 cm diameter) coil on a 7 T human scanner. All coils could be tuned/matched and driven in the single coil or array coil mode to the resonant frequencies of H-1 (698 and 298 MHz), H-2 (107 and 45.8 MHz), or O-17 (94.7 and 40.4 MHz) for imaging measurements and evaluation at 16.4 and 7 T, respectively. The dual-frequency resonant coil or array provides adequate detection sensitivity for H-1 MRI and excellent performance for low-? X-nuclear MRS imaging applications, and excellent coil decoupling efficiency between the array coils at both resonant frequencies with an optimal geometric overlap. It provides a simple, cost-effective dual-frequency RF coil solution to perform low-? X-nuclear MRS imaging for preclinical and human applications, especially at ultrahigh fields.
引用
收藏
页数:15
相关论文
共 62 条
[21]   HIGH-POWER H-1-F-19 EXCITATION IN A MULTIPLE-RESONANCE SINGLE-COIL CIRCUIT [J].
KENDRICK, RD ;
YANNONI, CS .
JOURNAL OF MAGNETIC RESONANCE, 1987, 75 (03) :506-508
[22]   Measuring Tumor Glycolytic Flux in Vivo by Using Fast Deuterium MRI [J].
Kreis, Felix ;
Wright, Alan J. ;
Hesse, Friederike ;
Fala, Maria ;
Hu, De-en ;
Brindle, Kevin M. .
RADIOLOGY, 2020, 294 (02) :289-296
[23]   COMPUTER MODELING OF SURFACE COIL SENSITIVITY [J].
LAWRY, TJ ;
WEINER, MW ;
MATSON, GB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :294-302
[24]   Measurement of unidirectional Pi to ATP flux in human visual cortex at 7 T by using in vivo 31P magnetic resonance spectroscopy [J].
Lei, H ;
Ugurbil, K ;
Chen, W .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :14409-14414
[25]   Machine Learning-Enabled High-Resolution Dynamic Deuterium MR Spectroscopic Imaging [J].
Li, Yudu ;
Zhao, Yibo ;
Guo, Rong ;
Wang, Tao ;
Zhang, Yi ;
Chrostek, Matthew ;
Low, Walter C. ;
Zhu, Xiao-Hong ;
Liang, Zhi-Pei ;
Chen, Wei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) :3879-3890
[26]  
Lu M., 2018, P INT SOC MAG RES ME
[27]  
Lu M., 2016, P INT SOC MAG RES ME
[28]   Quantitative assessment of brain glucose metabolic rates using in vivo deuterium magnetic resonance spectroscopy [J].
Lu, Ming ;
Zhu, Xiao-Hong ;
Zhang, Yi ;
Mateescu, Gheorghe ;
Chen, Wei .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (11) :3518-3530
[29]  
Mateescu GD, 2011, ADV EXP MED BIOL, V701, P193, DOI 10.1007/978-1-4419-7756-4_26
[30]  
Matson GB, 1999, MAGNET RESON MED, V42, P173, DOI 10.1002/(SICI)1522-2594(199907)42:1<173::AID-MRM23>3.0.CO