Cross-scanner harmonization methods for structural MRI may need further work: A comparison study

被引:17
作者
Gebre, Robel K. [1 ,5 ]
Senjem, Matthew L. [1 ,2 ]
Raghavan, Sheelakumari [1 ]
Schwarz, Christopher G. [1 ]
Gunter, Jeffery L. [1 ]
Hofrenning, Ekaterina I. [3 ]
Reid, Robert I. [2 ]
Kantarci, Kejal [1 ]
Graff-Radford, Jonathan [4 ]
Knopman, David S. [4 ]
Petersen, Ronald C. [4 ]
Jack Jr, Clifford R. [1 ]
Vemuri, Prashanthi [1 ,5 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Informat Technol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Quantitat Hlth Sci, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[5] Mayo Clin & Mayo Fdn, 200 First St SW, Rochester, MN 55905 USA
关键词
Deep learning; Structural MRI; Scan harmonization; CORTICAL THICKNESS;
D O I
10.1016/j.neuroimage.2023.119912
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The clinical usefulness MRI biomarkers for aging and dementia studies relies on precise brain morphological mea-surements; however, scanner and/or protocol variations may introduce noise or bias. One approach to address this is post-acquisition scan harmonization. In this work, we evaluate deep learning (neural style transfer, Cycle-GAN and CGAN), histogram matching, and statistical (ComBat and LongComBat) methods. Participants who had been scanned on both GE and Siemens scanners (cross-sectional participants, known as Crossover (n = 113), and longitudinally scanned participants on both scanners (n = 454)) were used. The goal was to match GE MPRAGE (T1-weighted) scans to Siemens improved resolution MPRAGE scans. Harmonization was performed on raw native and preprocessed (resampled, affine transformed to template space) scans. Cortical thicknesses were measured using FreeSurfer (v.7.1.1). Distributions were checked using Kolmogorov-Smirnov tests. Intra-class correlation (ICC) was used to assess the degree of agreement in the Crossover datasets and annualized percent change in cor-tical thickness was calculated to evaluate the Longitudinal datasets. Prior to harmonization, the least agreement was found at the frontal pole (ICC = 0.72) for the raw native scans, and at caudal anterior cingulate (0.76) and frontal pole (0.54) for the preprocessed scans. Harmonization with NST, CycleGAN, and HM improved the ICCs of the preprocessed scans at the caudal anterior cingulate ( > 0.81) and frontal poles ( > 0.67). In the Longitudinal raw native scans, over-and under-estimations of cortical thickness were observed due to the changing of the scanners. ComBat matched the cortical thickness distributions throughout but was not able to increase the ICCs or remove the effects of scanner changeover in the Longitudinal datasets. CycleGAN and NST performed slightly better to address the cortical thickness variations between scanner change. However, none of the methods suc-ceeded in harmonizing the Longitudinal dataset. CGAN was the worst performer for both datasets. In conclusion, the performance of the methods was overall similar and region dependent. Future research is needed to improve the existing approaches since none of them outperformed each other in terms of harmonizing the datasets at all ROIs. The findings of this study establish framework for future research into the scan harmonization problem.
引用
收藏
页数:11
相关论文
共 31 条
[11]   Autoencoder based self-supervised test-time adaptation for medical image analysis [J].
He, Yufan ;
Carass, Aaron ;
Zuo, Lianrui ;
Dewey, Blake E. ;
Prince, Jerry L. .
MEDICAL IMAGE ANALYSIS, 2021, 72
[12]   Reliability of structural MRI measurements: The effects of scan session, head tilt, inter-scan interval, acquisition sequence, FreeSurfer version and processing stream [J].
Hedges, Emily P. ;
Dimitrov, Mihail ;
Zahid, Uzma ;
Vega, Barbara Brito ;
Si, Shuqing ;
Dickson, Hannah ;
McGuire, Philip ;
Williams, Steven ;
Barker, Gareth J. ;
Kempton, Matthew J. .
NEUROIMAGE, 2022, 246
[13]   Image-to-Image Translation with Conditional Adversarial Networks [J].
Isola, Phillip ;
Zhu, Jun-Yan ;
Zhou, Tinghui ;
Efros, Alexei A. .
30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, :5967-5976
[14]   Adjusting batch effects in microarray expression data using empirical Bayes methods [J].
Johnson, W. Evan ;
Li, Cheng ;
Rabinovic, Ariel .
BIOSTATISTICS, 2007, 8 (01) :118-127
[15]  
Kingma DP, 2014, ADV NEUR IN, V27
[16]   Style Transfer Using Generative Adversarial Networks for Multi-site MRI Harmonization [J].
Liu, Mengting ;
Maiti, Piyush ;
Thomopoulos, Sophia ;
Zhu, Alyssa ;
Chai, Yaqiong ;
Kim, Hosung ;
Jahanshad, Neda .
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT III, 2021, 12903 :313-322
[17]   A comparison of batch effect removal methods for enhancement of prediction performance using MAQC-II microarray gene expression data [J].
Luo, J. ;
Schumacher, M. ;
Scherer, A. ;
Sanoudou, D. ;
Megherbi, D. ;
Davison, T. ;
Shi, T. ;
Tong, W. ;
Shi, L. ;
Hong, H. ;
Zhao, C. ;
Elloumi, F. ;
Shi, W. ;
Thomas, R. ;
Lin, S. ;
Tillinghast, G. ;
Liu, G. ;
Zhou, Y. ;
Herman, D. ;
Li, Y. ;
Deng, Y. ;
Fang, H. ;
Bushel, P. ;
Woods, M. ;
Zhang, J. .
PHARMACOGENOMICS JOURNAL, 2010, 10 (04) :278-291
[18]  
Mirza M., 2014, CoRR, DOI DOI 10.48550/ARXIV.1411.1784
[19]  
Nyúl LG, 1999, MAGNET RESON MED, V42, P1072, DOI 10.1002/(SICI)1522-2594(199912)42:6<1072::AID-MRM11>3.0.CO
[20]  
2-M