A Novel Frequency-Tracking Algorithm for Noncontact Vital Sign Monitoring

被引:15
作者
Cao, Lin [1 ,2 ]
Wei, Ran [1 ,2 ]
Zhao, Zongmin [1 ,2 ]
Wang, Dongfeng [3 ,4 ]
Fu, Chong [5 ]
机构
[1] Beijing Informat Sci & Technol Univ, Key Lab Informat & Commun Syst, Minist Informat Ind, Beijing 100101, Peoples R China
[2] Beijing Informat Sci & Technol Univ, Key Lab, Minist Educ Optoelect Measurement Technol & Instr, Beijing 100101, Peoples R China
[3] Beijing Informat Sci & Technol Univ, Sch Informat & Commun Engn, Beijing 100101, Peoples R China
[4] Beijing TransMicrowave Technol Co, Beijing 100080, Peoples R China
[5] Northeastern Univ, Sch Comp Sci & Engn, Shenyang 110169, Peoples R China
基金
美国国家科学基金会;
关键词
Birth-death strategy; frequency-tracking algorithm; mm-wave frequency-modulated continuous wave (FMCW) radar; vital sign monitoring; UWB IMPULSE RADAR;
D O I
10.1109/JSEN.2023.3306580
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Noncontact vital sign monitoring, based on mm-wave frequency-modulated continuous wave (FMCW) radar, can be widely applied in elderly care, clinical diagnoses, and in-vehicle occupant detection. The radar can monitor the Doppler signal reflected by the chest displacement and then analyze the phase change of echo to get the respiration and heartbeat signals. This article proposes a frequency-tracking method based on an improved birth-death strategy to calculate vital sign rate in real-time. There are two main steps to estimate the vital sign rate from frames within a second. First, the M-Rife algorithm is employed to interpolate the frequency of each frame. Second, find the matching frequency points between the adjacent frames in a second by using an improved birth-death strategy and calculate the frequency ratio for each matching point link. Then, choose the longest link whose initial frequency is closer to the frequency at the last second. The value of the link tail will be a vital sign rate at the current second. The proposed method is simulated in a public noncontact vital dataset to verify its feasibility and accuracy. To further demonstrate the method, this article carried out a series of experiments. The experimental results show that the method has an accuracy rate of 98% for the heartbeat rate in real-time and reduces the effect of clutter and respiratory harmonics on the heartbeat rate.
引用
收藏
页码:23044 / 23057
页数:14
相关论文
共 32 条
[1]   Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar [J].
Alizadeh, Mostafa ;
Shaker, George ;
Martins De Almeida, Joao Carlos ;
Morita, Plinio Pelegrini ;
Safavi-Naeini, Safeddin .
IEEE ACCESS, 2019, 7 :54958-54968
[2]   Wireless Sleep Apnea Detection Using Continuous Wave Quadrature Doppler Radar [J].
Baboli, Mehran ;
Singh, Aditya ;
Soll, Bruce ;
Boric-Lubecke, Olga ;
Lubecke, Victor M. .
IEEE SENSORS JOURNAL, 2020, 20 (01) :538-545
[3]   Multi-Subject Heart Rate Estimation and Real-Time Tracking Using a mmWave Radar and Trace Carving Algorithm [J].
Bauder, Chandler J. ;
Moadi, Abdel-Kareem ;
Joshi, Marvin ;
Fathy, Aly E. .
2022 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS 2022), 2022, :955-958
[4]  
Boashash B., 2016, TIME FREQUENCY SIGNA, P693
[5]  
CARO CG, 1971, LANCET, V2, P959
[6]   Remote Vital Sign Monitoring With Reduced Random Body Swaying Motion Using Heartbeat Template and Wavelet Transform Based on Constellation Diagrams [J].
Dai, Toan K. Vo ;
Yu, Yao ;
Theilmann, Paul ;
Fathy, Aly E. ;
Kilic, Ozlem .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2022, 6 (03) :429-436
[7]  
Deng Zhenmiao, 2006, Journal of Data Acquisition & Processing, V21, P473
[8]   A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods [J].
Desquins, Theo ;
Bousefsaf, Frederic ;
Pruski, Alain ;
Maaoui, Choubeila .
APPLIED SCIENCES-BASEL, 2022, 12 (19)
[9]   A Radar-Based Smart Sensor for Unobtrusive Elderly Monitoring in Ambient Assisted Living Applications [J].
Diraco, Giovanni ;
Leone, Alessandro ;
Siciliano, Pietro .
BIOSENSORS-BASEL, 2017, 7 (04)
[10]  
Feng Jiu-chao, 2010, Journal of South China University of Technology, V38, P1, DOI 10.3969/j.issn.1000-565X.2010.10.001