Keratometry Agreement Between Two Swept-Source OCT Devices in Healthy and Post-refractive Surgery Eyes

被引:2
作者
Martinez-Albert, Noelia [1 ]
Carlos Nieto-Fernandez, Juan [1 ,2 ]
Vicente Garcia-Marques, Jose [2 ]
机构
[1] AVANZA Ophthalmol Clin, Valencia, Spain
[2] Univ Valencia, Dept Optic & Optometry & Vision Sci, Valencia, Spain
关键词
POSTERIOR CORNEAL ASTIGMATISM; INTRAOCULAR-LENS POWER; PRECISION REPEATABILITY; STATISTICAL-METHODS; REPRODUCIBILITY; ANTERIOR; SURFACE; INDEX;
D O I
10.3928/1081597X-20230202-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the keratometry agreement between two swept-source devices for healthy and post-refractive sur-gery eyes and compare them.METHODS: One hundred volunteers between 20 and 55 years of age were recruited for this study including both healthy and post-refractive surgery eyes. Three consecutive measure-ments of simulated keratometry (Sim K), posterior keratom-etry (PK), and total keratometry (TK) were obtained with the IOLMaster 700 and Anterion. The agreement was assessed through the Bland-Altman method. Limits of agreement (LoA) were calculated as mean difference +/- 1.96 center dot SD and it rep-resents the 95% of the differences between devices.RESULTS: For both groups, Sim K measurements exhibited a mean difference close to 0 and within a range of +/- 0.30 and +/- 0.36 diopters (D) for the control and post-refractive surgery groups, respectively. Meanwhile, the IOLMaster 700 provid-ed flatter PK values (0.30 D on average) for both groups. In general, the post-refractive surgery group exhibited slightly greater mean differences and wider 95% LoA than the control group for Sim K and PK. Steeper TK values were obtained by the IOLMaster in both groups (control = 0.50 D and post -refractive surgery = 0.75 D). TK differences between devices were significantly greater in the post-refractive surgery group (ranging from 0.38 to 1.14 D) compared to the control group (ranging from 0.15 to 0.85 D).CONCLUSIONS: The IOLMaster 700 and Anterion are not interchangeable for TK measurements and eyes that had corneal refractive surgery even decreased the agreement between devices. Differences between devices for Sim K and PK measurements should be clinically judged, particularly in eyes with previous corneal surgery.
引用
收藏
页码:347 / +
页数:9
相关论文
共 24 条
  • [1] Asam JS., 2019, High Resolution Imaging in Microscopy and Ophthalmology, P285, DOI [DOI 10.1007/978-3-030-16638-0, 10.1007/978-3-030-16638-0_13, DOI 10.1007/978-3-030-16638-0_13]
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement
    Cheng, Li-Sheng
    Tsai, Ching-Yao
    Tsai, Ray Jui-Fang
    Liou, Shiow-Wen
    Ho, Jau-Der
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 417 - 422
  • [4] The shape of the anterior and posterior surface of the aging human cornea
    Dubbelman, M
    Sicarn, VADP
    Van der Heijde, GL
    [J]. VISION RESEARCH, 2006, 46 (6-7) : 993 - 1001
  • [5] Comparison of 2 swept-source optical coherence tomography-based biometry devices
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01) : 87 - 92
  • [6] Origins of the Keratometer and its Evolving Role in Ophthalmology
    Gutmark, Ron
    Guyton, David L.
    [J]. SURVEY OF OPHTHALMOLOGY, 2010, 55 (05) : 481 - 497
  • [7] Jarade EF, 2006, J REFRACT SURG, V22, P75
  • [8] Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature
    Jin, Haiying
    Ou, Zhongmin
    Guo, Haike
    Zhao, Peiquan
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S151 - S157
  • [9] Contribution of posterior corneal astigmatism to total corneal astigmatism
    Koch, Douglas D.
    Ali, Shazia F.
    Weikert, Mitchell P.
    Shirayama, Mariko
    Jenkins, Richard
    Wang, Li
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) : 2080 - 2087
  • [10] Measurement of Posterior Corneal Astigmatism by the I=OLMaster 700
    LaHood, Benjamin R.
    Goggin, Michael
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (05) : 331 - +