Validation of three-dimensional facial imaging captured with smartphone-based photogrammetry application in comparison to stereophotogrammetry system

被引:23
作者
Andrews, James [1 ]
Alwafi, Abdulraheem [2 ]
Bichu, Yashodhan M.
Pliska, Benjamin T. [3 ]
Mostafa, Nesrine [3 ]
Zou, Bingshuang [3 ]
机构
[1] Univ British Columbia, Fac Dent, Dept Oral Hlth Sci, Grad Orthodont, Vancouver, BC, Canada
[2] King Abdulaziz Univ, Fac Dent, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[3] Univ British Columbia, Fac Dent, Dept Oral Hlth Sci, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
关键词
3D facial imaging; Smartphone; Validation; TrueDepth scanner; Stereophotogrammetry; RELIABILITY; ACCURACY; PRECISION; SCANNER; REPRODUCIBILITY; TOOL;
D O I
10.1016/j.heliyon.2023.e15834
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Statement of problem: The development of facial scanners has improved capabilities to create three-dimensional (3D) virtual patients for accurate facial and smile analysis. However, most of these scanners are expensive, stationary and involve a significant clinical footprint. The use of the Apple iPhone and its integrated "TrueDepth" near-infrared (NIR) scanner combined with an image processing application (app) offers the potential to capture and analyze the unique 3D nature of the face; the accuracy and reliability of which are yet to be established for use in clinical dentistry. Purpose: This study was designed to validate both the trueness and precision of the iPhone 11 Pro smartphone TrueDepth NIR scanner in conjunction with the Bellus3D Face app in capturing 3D facial images in a sample of adult participants in comparison to the conventional 3dMDface stereophotogrammetry system.Material and methods: Twenty-nine adult participants were prospectively recruited. Eighteen soft tissue landmarks were marked on each participant's face before imaging. 3D facial images were captured using a 3dMDface system and the Apple iPhone TrueDepth NIR scanner combined with the Bellus3D Face app respectively. The best fit of each experimental model to the 3dMD scan was analyzed using Geomagic Control X software. The root mean square (RMS) was used to measure the "trueness" as the absolute deviation of each TrueDepth scan from the reference 3dMD image. Individual facial landmark deviations were also assessed to evaluate the reliability in different craniofacial regions. The "precision" of the smartphone was tested by taking 10 consecutive scans of the same subject and comparing those to the reference scan. Intra-observer and inter-observer reliabilities were assessed using the intra-class correlation coefficient (ICC).Results: Relative to the 3dMDface system, the mean RMS difference of the iPhone/Bellus3D app was 0.86 +/- 0.31 mm. 97% of all the landmarks were within 2 mm of error compared with the reference data. The ICC for intra-observer reproducibility or precision of the iPhone/Bellus3D app was 0.96, which was classified as excellent. The ICC for inter-observer reliability was 0.84, which was classified as good.Conclusions: These results suggest that 3D facial images acquired with this system, the iPhone TrueDepth NIR camera in conjunction with the Bellus3D Face app, are clinically accurate and reliable. Judicious use is advised in clinical situations that require high degrees of detail due to a lack of image resolution and a longer acquisition time. Generally, this system possesses the po-tential to serve as a practical alternative to conventional stereophotogrammetry systems for use in a clinical setting due to its accessibility and relative ease of use and further research is planned to appraise its updated clinical use.
引用
收藏
页数:11
相关论文
共 35 条
[1]   Reliability of reference distances used in photogrammetry [J].
Aksu, Muge ;
Kaya, Demet ;
Kocadereli, Ilken .
ANGLE ORTHODONTIST, 2010, 80 (04) :670-677
[2]   Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images [J].
Aldridge, K ;
Boyadjiev, SA ;
Capone, GT ;
DeLeon, VB ;
Richtsmeier, JT .
AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2005, 138A (03) :247-253
[3]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[4]  
Bechtold TE, 2012, J OROFAC ORTHOP, V73, P126, DOI 10.1007/s00056-011-0060-1
[5]   Validation of the Vectra H1 portable three-dimensional photogrammetry system for facial imaging [J].
Camison, L. ;
Bykowski, M. ;
Lee, W. W. ;
Carlson, J. C. ;
Roosenboom, J. ;
Goldstein, J. A. ;
Losee, J. E. ;
Weinberg, S. M. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (03) :403-410
[6]   Chairside 3D digital design and trial restoration workflow [J].
Coachman, Christian ;
Georg, Ralph ;
Bohner, Lauren ;
Rigo, Lindiane Cogo ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05) :514-520
[7]   Facially generated and cephalometric guided 3D digital design for complete mouth implant rehabilitation: A clinical report [J].
Coachman, Christian ;
Calamita, Marcelo Alexandre ;
Gray Coachman, Francis ;
Coachman, Robert Gray ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) :577-586
[8]   A comparison between stereophotogrammetry and smartphone structured light technology for three-dimensional face scanning [J].
D'Ettorre, Giorgio ;
Farronato, Marco ;
Candida, Ettore ;
Quinzi, Vincenzo ;
Grippaudo, Cristina .
ANGLE ORTHODONTIST, 2022, 92 (03) :358-363
[9]   Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems [J].
Fourie, Zacharias ;
Damstra, Janalt ;
Gerrits, Peter O. ;
Ren, Yijin .
FORENSIC SCIENCE INTERNATIONAL, 2011, 207 (1-3) :127-134
[10]   Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device [J].
Gibelli, Daniele ;
Pucciarelli, Valentina ;
Cappella, Annalisa ;
Dolci, Claudia ;
Sforza, Chiarella .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (08) :1772-1784