Short-term Changes in Epithelial and Optical Redistribution Induced by Different Orthokeratology Designs

被引:3
作者
Meng, Ziqi [1 ,2 ,3 ,4 ]
Chen, Siping [3 ,4 ]
Zhe, Nan [3 ,4 ]
Cao, Tongxin [5 ,6 ,7 ]
Li, Zhangliang [3 ,4 ]
Zhang, Yunjie [3 ,4 ]
Wei, Ruihua [1 ,2 ]
机构
[1] Tianjin Med Univ, Eye Inst, Tianjin Key Lab Retinal Funct & Dis, Natl Clin Res Ctr Ocular Dis,Tianjin Branch,Eye Ho, 251 Fukang Rd, Tianjin 300384, Peoples R China
[2] Tianjin Med Univ, Sch Optometry, Eye Hosp, 251 Fukang Rd, Tianjin 300384, Peoples R China
[3] Wenzhou Med Univ, Eye Hosp, Wenzhou, Peoples R China
[4] Wenzhou Med Univ, Sch Ophthalmol & Optometry, 270 West Xueyuan Rd, Wenzhou 325027, Zhejiang, Peoples R China
[5] Natl Clin Res Ctr Ocular Dis, Wenzhou, Peoples R China
[6] Wenzhou Med Univ, Eye Hosp, Hangzhou Branch, Hangzhou, Peoples R China
[7] Columbia Univ, Irving Med Ctr, Mailman Sch Publ Hlth, New York, NY USA
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2023年 / 49卷 / 12期
关键词
Orthokeratology; Corneal epithelium; Spectral-domain optical coherence tomography; CORNEAL EPITHELIUM; COHERENCE TOMOGRAPHY; LENS DESIGNS; MYOPIA; WEAR; MAP;
D O I
10.1097/ICL.0000000000001045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives:This study aimed to investigate corneal epithelial and topographic changes caused by two commercial myopia orthokeratology (ortho-k) designs.Methods:Twenty-six subjects fitted with vision shape treatment (VST) lenses and 30 subjects fitted with corneal reshaping therapy (CRT) lenses were reviewed 1 day, 1 week, and 1 month after lens initiation. A spectral-domain optical coherence tomography system was used to create epithelial maps that were in turn used to determine the average epithelial thickness of each zone and the diameter of treatment zone. By measuring the topographic tangential differential map, the treatment zone diameter and the power and width of the high convex zone (HCZ) were obtained. All epithelial thicknesses and topographic corneal variations recorded were analyzed.Results:At the central zone, the epithelial thickness changes (oET) decreased significantly after 1 day of ortho-k in two groups. At 2- to 9-mm peripheral zone, ortho-k increased oET until 1 week in the VST group, whereas it kept increasing in the CRT group after 1 week. At 1 month, the central oET is -9.51 +/- 2.38 mm in the VST group, which was comparable to -8.72 +/- 3.43 mm in the CRT group. The nasal HCZ power and the oET of nasal and inferior nasal were significantly larger in the CRT group. A positive correlation was found between the HCZ power and oET generated by VST-type lenses inferiorly and temporally. For the CRT group, a positive correlation was found between inferior HCZ power and oET.Conclusions:At the early stage of ortho-k, epithelial thickness and topography change quickly and simultaneously. Epithelial changes were in line with corneal topography reshaping. Epithelial and optical remodelling were affected by different lens types.
引用
收藏
页码:528 / 534
页数:7
相关论文
共 50 条
[41]   Influence of optical zone on myopic correction in small incision lenticule extraction: a short-term study [J].
Liu, Pan ;
Yu, Dongyu ;
Zhang, Boyu ;
Zhou, Shiqi ;
Zhu, Haoran ;
Qin, Wanyun ;
Ye, Xinqi ;
Li, Xianghui ;
Zhang, Yan ;
Bai, Ying ;
Wang, Yuan ;
Shao, Zhengbo .
BMC OPHTHALMOLOGY, 2022, 22 (01)
[42]   Anterior segment changes following short-term reading and its correlation with corneal biomechanical characteristics [J].
Niyazmand, Hamed ;
Moghaddam, Hadi Ostadi ;
Sedaghat, Mohammad Reza ;
Hosseini, Seyed Mahdi Ahmadi ;
Abolbashari, Fereshteh .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (05) :592-596
[43]   Impact of Forms of Visual Attenuation on Short-Term Eye Changes Under Controlled Reading Visibility [J].
Su, Huanjun ;
Chun, Rachel Ka Man ;
De Lestrange-Anginieur, Elie .
EYE AND BRAIN, 2024, 16 :133-146
[44]   Impact of multifocal gas-permeable lens designs on short-term choroidal response, axial length, and retinal defocus profile [J].
Alanazi, Muteb ;
Caroline, Patrick ;
Alshamrani, Amane ;
Liu, Maria .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (02) :247-256
[45]   Total knee replacement system with a ceramic femoral component versus two traditional metallic designs: a prospective short-term study [J].
Bergschmidt, Philipp ;
Bader, Rainer ;
Kluess, Daniel ;
Zietz, Carmen ;
Schwemmer, Benjamin ;
Kundt, Guenther ;
Mittelmeier, Wolfram .
JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) :294-299
[46]   Short-Term Intraocular Pressure Rise during Locally Induced Force by Ophthalmologic Surgery Applications [J].
Koelbl, Philipp Simon ;
Werner, Jens Ulrich ;
Enders, Christian ;
Lingenfelder, Christian ;
Koch, Frank H. J. ;
Hessling, Martin .
OPHTHALMIC RESEARCH, 2019, 61 (03) :159-167
[47]   Acute and short-term changes in visual function with multifocal soft contact lens wear in young adults [J].
Kang, Pauline ;
Wildsoet, Christine F. .
CONTACT LENS & ANTERIOR EYE, 2016, 39 (02) :133-140
[48]   Scleral lens induced short term corneal changes in eyes with Pellucid Marginal Degeneration [J].
Dutta, Ronit ;
Iyer, Geetha ;
Srinivasan, Bhaskar ;
Iqbal, Asif .
CONTACT LENS & ANTERIOR EYE, 2024, 47 (03)
[49]   Short-term Comparison of Refractive Errors between Two Different Age Groups after LASEK for Moderate Myopia [J].
Kim, Mi Jeong ;
An, Ji Seon ;
Moon, Ja Yoon ;
Kim, Hee Young ;
Choi, Jin Seok ;
Pak, Kyu Hong ;
Chung, Sung Kun .
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (11) :1478-1482
[50]   Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation [J].
Zhu, Qiu-Jian ;
Chen, Wen-Jing ;
Zhu, Wei-Jian ;
Xiao, Hai-Xiang ;
Zhu, Man-Hui ;
Ma, Lie ;
Yuan, You ;
Song, E. .
BMC OPHTHALMOLOGY, 2021, 21 (01)