Preoperative Prediction of Optimal Femoral Implant Size by Regularized Regression on 3D Femoral Bone Shape

被引:1
|
作者
Lambrechts, Adriaan [1 ]
Van Dijck, Christophe [1 ]
Wirix-Speetjens, Roel [1 ]
Vander Sloten, Jos [2 ]
Maes, Frederik [3 ,4 ]
Van Huffel, Sabine [5 ]
机构
[1] Materialise NV, B-3001 Leuven, Belgium
[2] Katholieke Univ Leuven, Biomech Sect, Mech Engn, B-3001 Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn ESAT, Proc Speech & Images PSI, B-3001 Leuven, Belgium
[4] UZ Leuven, Med Imaging Res Ctr, B-3000 Leuven, Belgium
[5] Katholieke Univ Leuven, STADIUS Ctr Dynam Syst, Dept Elect Engn ESAT, Signal Proc & Data Analyt, B-3001 Leuven, Belgium
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 07期
关键词
total knee arthroplasty; templating; machine learning; group lasso; TOTAL KNEE ARTHROPLASTY; COMPONENT; ACCURACY; RISK;
D O I
10.3390/app13074344
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Preoperative determination of implant size for total knee arthroplasty surgery has numerous clinical and logistical benefits. Currently, surgeons use X-ray-based templating to estimate implant size, but this method has low accuracy. Our study aims to improve accuracy by developing a machine learning approach that predicts the required implant size based on a 3D femoral bone mesh, the key factor in determining the correct implant size. A linear regression framework imposing group sparsity on the 3D bone mesh vertex coordinates was proposed based on a dataset of 446 MRI scans. The group sparse regression method was further regularized based on the connectivity of the bone mesh to enforce neighbouring vertices to have similar importance to the model. Our hypergraph regularized group lasso had an accuracy of 70.1% in predicting femoral implant size while the initial implant size prediction provided by the instrumentation manufacturer to the surgeon has an accuracy of 23.1%. Furthermore, our method was capable of predicting the implant size up to one size smaller or larger with an accuracy of 99.1%, thereby surpassing other state-of-the-art methods. The hypergraph regularized group lasso was able to obtain a significantly higher accuracy compared to the implant size prediction provided by the instrumentation manufacturer.
引用
收藏
页数:13
相关论文
共 49 条
  • [31] Leveraging Machine Learning for Optimized Mechanical Properties and 3D Printing of PLA/cHAP for Bone Implant
    Omigbodun, Francis T.
    Osa-Uwagboe, Norman
    Udu, Amadi Gabriel
    Oladapo, Bankole I.
    BIOMIMETICS, 2024, 9 (10)
  • [32] Preoperative 3D CT Planning for Cortical Bone Trajectory Screws: A Retrospective Radiological Cohort Study
    Penner, Federica
    Marengo, Nicola
    Ajello, Marco
    Petrone, Salvatore
    Cofano, Fabio
    Santonio, Filippo Veneziani
    Zenga, Francesco
    Garbossa, Diego
    WORLD NEUROSURGERY, 2019, 126 : E1468 - E1474
  • [33] Disulfide Connectivity Prediction Based on Modelled Protein 3D Structural Information and Random Forest Regression
    Yu, Dong-Jun
    Li, Yang
    Hu, Jun
    Yang, Xibei
    Yang, Jing-Yu
    Shen, Hong-Bin
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2015, 12 (03) : 611 - 621
  • [34] Assessments of jaw bone density at implant sites using 3D cone-beam computed tomography
    Hao, Y.
    Zhao, W.
    Wang, Y.
    Yu, J.
    Zou, D.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (09) : 1398 - 1403
  • [35] Can a Musculoskeletal Model Adapted to Knee Implant Geometry Improve Prediction of 3D Contact Forces and Moments?
    Guitteny, Sacha
    Aissaoui, Rachid
    Dumas, Raphael
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (08) : 1872 - 1883
  • [36] Post-operative 3D CT feedback improves accuracy and precision in the learning curve of anatomic ACL femoral tunnel placement
    Sirleo, Luigi
    Innocenti, Massimo
    Innocenti, Matteo
    Civinini, Roberto
    Carulli, Christian
    Matassi, Fabrizio
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (02) : 468 - 477
  • [37] Shape Trumps Size: Image-Based Morphological Analysis Reveals That the 3D Shape Discriminates Intracranial Aneurysm Disease Status Better Than Aneurysm Size
    Juchler, Norman
    Schilling, Sabine
    Bijlenga, Philippe
    Kurtcuoglu, Vartan
    Hirsch, Sven
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [38] Post-operative 3D CT feedback improves accuracy and precision in the learning curve of anatomic ACL femoral tunnel placement
    Luigi Sirleo
    Massimo Innocenti
    Matteo Innocenti
    Roberto Civinini
    Christian Carulli
    Fabrizio Matassi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 468 - 477
  • [39] Femoral and Tibial Torsion Measurement in Children and Adolescents: Comparison of 3D Models Based on Low- Dose Biplanar Radiography and LowDose CT
    Rosskopf, Andrea B.
    Ramseier, Leonhard E.
    Sutter, Reto
    Pfirrmann, Christian W. A.
    Buck, Florian M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) : W285 - W291
  • [40] Association between osteoporotic femoral neck fractures and DXA-derived 3D measurements at lumbar spine: a case-control study
    Lopez Picazo, Mirella
    Humbert, Ludovic
    Winzenrieth, Renaud
    Di Gregorio, Silvana
    Gonzalez Ballester, Miguel A.
    del Rio Barquero, Luis M.
    ARCHIVES OF OSTEOPOROSIS, 2020, 15 (01)