Preoperative Prediction of Optimal Femoral Implant Size by Regularized Regression on 3D Femoral Bone Shape

被引:1
|
作者
Lambrechts, Adriaan [1 ]
Van Dijck, Christophe [1 ]
Wirix-Speetjens, Roel [1 ]
Vander Sloten, Jos [2 ]
Maes, Frederik [3 ,4 ]
Van Huffel, Sabine [5 ]
机构
[1] Materialise NV, B-3001 Leuven, Belgium
[2] Katholieke Univ Leuven, Biomech Sect, Mech Engn, B-3001 Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Elect Engn ESAT, Proc Speech & Images PSI, B-3001 Leuven, Belgium
[4] UZ Leuven, Med Imaging Res Ctr, B-3000 Leuven, Belgium
[5] Katholieke Univ Leuven, STADIUS Ctr Dynam Syst, Dept Elect Engn ESAT, Signal Proc & Data Analyt, B-3001 Leuven, Belgium
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 07期
关键词
total knee arthroplasty; templating; machine learning; group lasso; TOTAL KNEE ARTHROPLASTY; COMPONENT; ACCURACY; RISK;
D O I
10.3390/app13074344
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Preoperative determination of implant size for total knee arthroplasty surgery has numerous clinical and logistical benefits. Currently, surgeons use X-ray-based templating to estimate implant size, but this method has low accuracy. Our study aims to improve accuracy by developing a machine learning approach that predicts the required implant size based on a 3D femoral bone mesh, the key factor in determining the correct implant size. A linear regression framework imposing group sparsity on the 3D bone mesh vertex coordinates was proposed based on a dataset of 446 MRI scans. The group sparse regression method was further regularized based on the connectivity of the bone mesh to enforce neighbouring vertices to have similar importance to the model. Our hypergraph regularized group lasso had an accuracy of 70.1% in predicting femoral implant size while the initial implant size prediction provided by the instrumentation manufacturer to the surgeon has an accuracy of 23.1%. Furthermore, our method was capable of predicting the implant size up to one size smaller or larger with an accuracy of 99.1%, thereby surpassing other state-of-the-art methods. The hypergraph regularized group lasso was able to obtain a significantly higher accuracy compared to the implant size prediction provided by the instrumentation manufacturer.
引用
收藏
页数:13
相关论文
共 49 条
  • [21] Prediction of total and regional body composition from 3D body shape
    Qiao, Chexuan
    Rolfe, Emanuella De Lucia
    Mak, Ethan
    Sengupta, Akash
    Powell, Richard
    Watson, Laura P. E.
    Heymsfield, Steven B.
    Shepherd, John A.
    Wareham, Nicholas
    Brage, Soren
    Cipolla, Roberto
    NPJ DIGITAL MEDICINE, 2024, 7 (01):
  • [22] Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs
    Dimitriou, D.
    Tsai, T. -Y.
    Yue, B.
    Rubash, H. E.
    Kwon, Y. -M.
    Li, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) : 91 - 97
  • [23] A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images
    Emma L. Robertson
    Martin Hengherr
    Felix Amsler
    Michael T. Hirschmann
    Dominic T. Mathis
    Skeletal Radiology, 2021, 50 : 1389 - 1397
  • [24] Preoperative implant selection for unilateral breast reconstruction using 3D imaging with the Microsoft Kinect sensor
    Pohlmann, Stefanie T. L.
    Harkness, Elaine
    Taylor, Christopher J.
    Gandhi, Ashu
    Astley, Susan M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (08) : 1059 - 1067
  • [25] A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images
    Robertson, Emma L.
    Hengherr, Martin
    Amsler, Felix
    Hirschmann, Michael T.
    Mathis, Dominic T.
    SKELETAL RADIOLOGY, 2021, 50 (07) : 1389 - 1397
  • [26] A novel approach for intra-operative shape acquisition of the tibio-femoral joints using 3D laser scanning in computer assisted orthopaedic surgery
    Joshi, Shailesh V.
    Rowe, Philip J.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (01)
  • [27] The correlation between common 2D femoral notch parameters and 3D notch volume: a retrospective MRI study
    Zhang, Chengyuan
    Zhang, Xuancheng
    Fang, Zhaoyi
    Wang, Feng
    Yuan, Feng
    Xie, Guoming
    Zhao, Jinzhong
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [28] 3D CT Study of Morphological Shape and Size of Sella Turcica in Bangladeshi Population
    Islam, Mushrath
    Alam, Mohammad Khursheed
    Yusof, Asilah
    Kato, Ikuro
    Honda, Yuma
    Kubo, Katsutoshi
    Maeda, Hatsuhiko
    JOURNAL OF HARD TISSUE BIOLOGY, 2017, 26 (01) : 1 - 6
  • [29] 3D Geometric Shape Reconstruction for Revision TKA and UKA Knees Using Gaussian Process Regression
    Zhou, Chaochao
    Cha, Thomas
    Peng, Yun
    Bedair, Hany
    Li, Guoan
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (12) : 3685 - 3697
  • [30] Printability prediction of food formulations for 3D printing using a Gaussian process regression model
    Maldonado-Rosas, Ruben
    Alfaro-Ponce, Mariel
    Cuan-Urquizo, Enrique
    Tejada-Ortigoza, Viridiana
    JOURNAL OF FOOD ENGINEERING, 2025, 395