Bath heaters using alternative heat transfer medium: a thermo-economic analysis

被引:13
作者
Delouei, Amin Amiri [1 ]
Karimnejad, Sajjad [2 ]
Gharajeh, Ayoub [3 ]
Sajjadi, Hasan [1 ]
Atashafrooz, Meysam [4 ]
Xie, Gongnan [5 ]
Arabkoohsar, Ahmad [6 ]
机构
[1] Univ Bojnord, Dept Mech Engn, Bojnord 9453155111, Iran
[2] Shahrood Univ Technol, Mech Engn Dept, Shahrood 3619995161, Iran
[3] North Khorasan Gas Co NKGC, Bojnord, Iran
[4] Sirjan Univ Technol, Dept Mech Engn, Sirjan, Iran
[5] Northwestern Polytech Univ, Sch Marine Sci & Technol, Xian 710072, Peoples R China
[6] Tech Univ Denmark, Dept Civil & Mech Engn, Lyngby, Denmark
关键词
Passive energy enhancement; Energy systems; Experimental techniques; Heat and mass transfer; Heat exchangers; CITY GATE STATION; PRESSURE REDUCTION STATIONS; PERFORMANCE ASSESSMENT; TRANSFER ENHANCEMENT; FUEL CONSUMPTION; EXERGY ANALYSIS; DROP STATION; ENERGY; EXCHANGER; SYSTEM;
D O I
10.1007/s40430-022-03989-8
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, the performance enhancement of a particular type of heater, i.e., water bath heater, with a wide range of industrial applications is proposed and assessed. The idea is centered around using an alternative working fluid with better heat transfer characteristics (heat transfer oil-HTO) to quantify the impacts not only from a technical point of view but also from an economic perspective. The indirect heater of Arkan CGS (located in North Khorasan province of Iran) is selected as the case study, and its laboratory model is constructed by dimensional analysis. The thermal analysis is done at different fluid flow rates in the heating coil of the experimental setup. The results are verified by both numerical simulation and available empirical correlation. The results show that using HTO as the heating medium leads to heater efficiency improvement by up to 158%, and it will also lead to energy savings of up to 36.5%. A comprehensive economic analysis is carried out based on the technical results. It is found that the internal rate of return and dynamic payback period are in the ranges of 42-67% and 1.53-2.17 years, respectively.
引用
收藏
页数:13
相关论文
共 54 条
  • [1] A comprehensive review on single phase heat transfer enhancement techniques in heat exchanger applications
    Alam, Tabish
    Kim, Man-Hoe
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 813 - 839
  • [2] Recovery of Wasted Mechanical Energy from the Reduction of Natural Gas Pressure
    Andrei, Iancu
    Valentin, Tudorache
    Cristina, Tarean
    Niculae, Toma
    [J]. 24TH DAAAM INTERNATIONAL SYMPOSIUM ON INTELLIGENT MANUFACTURING AND AUTOMATION, 2013, 2014, 69 : 986 - 990
  • [3] Angelo W, 2007, 14 INT HEAT PIPE C
  • [4] [Anonymous], 2020, DNV GL ANN REPORT
  • [5] A new design for natural gas pressure reduction points by employing a turbo expander and a solar heating set
    Arabkoohsar, A.
    Farzaneh-Gord, M.
    Deymi-Dashtebayaz, M.
    Machado, L.
    Koury, R. N. N.
    [J]. RENEWABLE ENERGY, 2015, 81 : 239 - 250
  • [6] Effect of various twisted-tape designs on the thermal and environmental performance of line-heaters in city gate stations
    Arabkoohsar, Ahmad
    Khosravi, Milad
    Alsagri, Ali Sulaiman
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [7] Ashouri E, 2013, J CHEM PET ENG, V47, P69
  • [8] The minimum gas temperature at the inlet of regulators in natural gas pressure reduction stations (CGS) for energy saving in water bath heaters
    Ashouri, Esmail
    Veysi, Farzad
    Shojaeizadeh, Ehsan
    Asadi, Maryam
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2014, 21 : 230 - 240
  • [9] Azizi S, 2014, Int J Sci Eng Invest, V3, P17
  • [10] CFD applications in various heat exchangers design: A review
    Bhutta, Muhammad Mahmood Aslam
    Hayat, Nasir
    Bashir, Muhammad Hassan
    Khan, Ahmer Rais
    Ahmad, Kanwar Naveed
    Khan, Sarfaraz
    [J]. APPLIED THERMAL ENGINEERING, 2012, 32 : 1 - 12