Echocardiography performed by the neonatologist: the impact on the clinical management

被引:7
作者
Figueira, Simone de Araujo Negreiros [1 ]
de Oliveira, Allan Chiaratti [1 ]
Zamith, Marina Maccagnano [2 ]
Metolina, Cristiane [1 ]
Miyoshi, Milton Harumi [1 ]
Sanudo, Adriana [3 ]
Guinsburg, Ruth [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Pediat, Div Neonatal Med, Escola Paulista Med, Sao Paulo, SP, Brazil
[2] Univ Fed Sao Paulo, Dept Internal Med, Escola Paulista Med, Sao Paulo, SP, Brazil
[3] Univ Fed Sao Paulo, Dept Prevent Med, Escola Paulista Med, Sao Paulo, SP, Brazil
关键词
TARGETED NEONATAL ECHOCARDIOGRAPHY; INTENSIVE-CARE-UNIT; FUNCTIONAL ECHOCARDIOGRAPHY; BLOOD-PRESSURE; OUTCOMES; AGE;
D O I
10.1038/s41390-023-02526-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe aim of this study was to assess whether neonatologist-performed echocardiography (NPE) changed the previously planned hemodynamic approach in critically ill newborn infants.MethodsThis prospective cross-sectional study included the first NPE of 199 neonates. Before the exam, the clinical team was asked about the planned hemodynamic approach and the answer was classified as an intention to change or not to change the therapy. After being informed about the NPE results, the clinical management was grouped as performed as previously planned (maintained) or modified.ResultsNPE modified the planned pre-exam approach in 80 cases (40.2%; 95% CI: 33.3-47.4%), and variables associated with an increased chance of this modification were exams to assess pulmonary hemodynamics (prevalent ratio (PR): 1.75; 95% CI: 1.02-3.00) and to assess systemic flow (PR: 1.68; 95% CI: 1.06-2.68) in relation to those requested for patent ductus arteriosus, pre-exam intention of changing the prescribed management (PR: 2.16; 95% CI: 1.50-3.11), use of catecholamines (PR: 1.68; 95% CI: 1.24-2.28) and birthweight (per kg) (PR: 0.81; 95% CI: 0.68-0.98).ConclusionThe NPE was an important tool to direct hemodynamic management in a different approach from the previous intention of the clinical team, mainly for critically ill neonates.ImpactThis study shows that neonatologist-performed echocardiography guides the therapeutic planning in the NICU, mainly in the more unstable newborns, with lower birthweight and receiving catecholamines.Exams requested with the intention of modifying the current approach were more likely to change the management in a different way than planned pre-exam.
引用
收藏
页码:724 / 729
页数:6
相关论文
共 24 条
[1]   Targeted neonatal echocardiography service in neonatal intensive care in Manitoba, Canada [J].
Alammary, Deima ;
Narvey, Michael ;
Soni, Reeni ;
Elsayed, Yasser ;
Louis, Deepak .
JOURNAL OF PERINATOLOGY, 2022, 42 (05) :655-659
[2]   Maximum vasoactive-inotropic score and mortality in extremely premature, extremely low birth weight infants [J].
Aziz, Khyzer B. ;
Lavilla, Orlyn C. ;
Wynn, James L. ;
Lure, Allison C. ;
Gipson, Daniel ;
de la Cruz, Diomel .
JOURNAL OF PERINATOLOGY, 2021, 41 (09) :2337-2344
[3]   Intervention and Outcome for Neonatal Hypotension [J].
Barrington, Keith ;
El-Khuffash, Afif ;
Dempsey, Eugene .
CLINICS IN PERINATOLOGY, 2020, 47 (03) :563-+
[4]   Early blood pressure, antihypotensive therapy and outcomes at 18-22months' corrected age in extremely preterm infants [J].
Batton, Beau ;
Li, Lei ;
Newman, Nancy S. ;
Das, Abhik ;
Watterberg, Kristi L. ;
Yoder, Bradley A. ;
Faix, Roger G. ;
Laughon, Matthew M. ;
Stoll, Barbara J. ;
Higgins, Rosemary D. ;
Walsh, Michele C. .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2016, 101 (03) :F201-F206
[5]   Vasoactive-Inotropic Score: Evolution, Clinical Utility, and Pitfalls [J].
Belletti, Alessandro ;
Lerose, Caterina Cecilia ;
Zangrillo, Alberto ;
Landoni, Giovanni .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (10) :3067-3077
[6]   Functional echocardiography in neonatal intensive care: 1 year experience in a unit in Spain [J].
Corredera, A. ;
Rodriguez, M. J. ;
Arevalo, P. ;
Llorente, B. ;
Moro, M. ;
Arruza, L. .
ANALES DE PEDIATRIA, 2014, 81 (03) :167-173
[7]   The role of Neonatologist Performed Echocardiography in the assessment and management of neonatal shock [J].
de Boode, Willem P. ;
van der Lee, Robin ;
Eriksen, Beate Horsberg ;
Nestaas, Eirik ;
Dempsey, Eugene ;
Singh, Yogen ;
Austin, Topun ;
El-Khuffash, Afif ;
Bohlin, K. ;
Bravo, M. C. ;
Breatnach, C. R. ;
Breindahl, M. ;
Groves, A. M. ;
Gupta, S. ;
Levy, P. T. ;
McNamara, P. J. ;
Molnar, Z. ;
Rogerson, S. R. ;
Roehr, C. C. ;
Savoia, M. ;
Schubert, U. ;
Schwarz, C. E. ;
Sehgal, A. ;
Slieker, M. G. ;
Tissot, C. ;
van Laere, D. ;
van Overmeire, B. ;
van Wyk, L. .
PEDIATRIC RESEARCH, 2018, 84 (01) :57-67
[8]   Application of Neonatologist Performed Echocardiography in the assessment and management of persistent pulmonary hypertension of the newborn [J].
de Boode, Willem P. ;
Singh, Yogen ;
Molnar, Zoltan ;
Schubert, Ulf ;
Savoia, Marilena ;
Sehgal, Arvind ;
Levy, Philip ;
McNamara, Patrick ;
El-Khuffash, Afif ;
Austin, T. ;
Bohlin, K. ;
Bravo, M. C. ;
Breatnach, C. R. ;
Breindahl, M. ;
Dempsey, E. ;
Groves, A. M. ;
Gupta, S. ;
Eriksen, Horsberg B. ;
Nestaas, E. ;
Rogerson, S. R. ;
Roehr, C. C. ;
Schwarz, C. E. ;
Slieker, M. G. ;
Tissot, C. ;
van der Lee, R. ;
van Laere, D. ;
van Overmeire, B. ;
van Wyk, L. .
PEDIATRIC RESEARCH, 2018, 84 (01) :68-77
[9]   Targeted neonatal echocardiography (TnECHO) service in a Canadian neonatal intensive care unit: a 4-year experience [J].
EL-Khuffash, A. ;
Herbozo, C. ;
Jain, A. ;
Lapointe, A. ;
McNamara, P. J. .
JOURNAL OF PERINATOLOGY, 2013, 33 (09) :687-690
[10]   Neonatologist-performed functional echocardiography in the neonatal intensive care unit [J].
El-Khuffash, Afif F. ;
McNamara, Patrick J. .
SEMINARS IN FETAL & NEONATAL MEDICINE, 2011, 16 (01) :50-60