Application of the ESHO-QA guidelines for determining the performance of the LCA superficial hyperthermia heating system

被引:3
作者
Carrapico-Seabra, Carolina [1 ,4 ]
De Lazzari, Mattia [2 ]
Ameziane, Abdelali [1 ]
van Rhoon, Gerard C. [1 ,3 ]
Trefna, Hana Dobsicek [2 ]
Curto, Sergio [1 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Dept Radiotherapy, Rotterdam, Netherlands
[2] Chalmers Univ Technol, Dept Elect Engn, Gothenburg, Sweden
[3] Delft Univ Technol, Fac Appl Sci, Dept Radiat Sci & Technol, Delft, Netherlands
[4] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Dept Radiotherapy, NL-3015 GD Rotterdam, Netherlands
关键词
Hyperthermia; quality assurance (QA); superficial applicators; LCA; QUALITY-ASSURANCE GUIDELINES; REGIONAL HYPERTHERMIA; RADIATION-THERAPY; LOCAL-CONTROL; PLUS HYPERTHERMIA; RANDOMIZED-TRIAL; PHASE-III; RECURRENT; CANCER; RADIOTHERAPY;
D O I
10.1080/02656736.2023.2272578
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose This study aimed to assess the quality of the lucite cone applicator (LCA), the standard applicator for superficial hyperthermia at the Erasmus MC Cancer Institute, using the most recent quality assurance guidelines, thus verifying their feasibility.Materials and methods The assessment was conducted on each of the six LCAs available for clinical treatments. The temperature distribution was evaluated using an infrared camera across different layers of a fat-muscle mimicking phantom. The maximum temperature increase, thermal effective penetration depth (TEPD), and thermal effective field size (TEFS) were used as quality metrics. The experimental results were validated through comparison with simulated results, using a canonical phantom model and a realistic phantom model segmented from CT imaging.Results A maximum temperature increase above 6 degrees C at 2 cm depth in the fat-muscle phantom for all the experiments was found. A mean negative difference between simulated and experimental data was of 1.3 degrees C when using the canonical phantom model. This value decreased to a mean negative difference of 0.4 degrees C when using the realistic model. Simulated and measured TEPD showed good agreement for both in silico scenarios, while discrepancies were present for TEFS.Conclusions The LCAs passed all QA guidelines requirements for superficial hyperthermia delivery when used singularly or in an array configuration. A further characterization of parameters such as antenna efficiency and heat transfer coefficients would be beneficial for translating experimental results to simulated values. Implementing the QA guidelines was time-consuming and demanding, requiring careful preparation and correct setup of antenna elements.
引用
收藏
页数:13
相关论文
共 37 条
[21]   Preoperative radiochemotherapy in locally advanced or recurrent rectal cancer: Regional radiofrequency hyperthermia correlates with clinical parameters [J].
Rau, B ;
Wust, P ;
Tilly, W ;
Gellermann, J ;
Harder, C ;
Riess, H ;
Budach, V ;
Felix, R ;
Schlag, PM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :381-391
[22]   Comparison of the clinical effectiveness of the 433 MHz lucite cone applicator with that of a conventional waveguide applicator in applications of superficial hyperthermia [J].
Rietveld, PJM ;
van Putten, WLJ ;
van der Zee, J ;
van Rhoon, GC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (03) :681-687
[23]   Quantitative evaluation of 2 x 2 arrays of Lucite cone applicators in flat layered phantoms using Gaussian-beam-predicted and thermographically measured SAR distributions [J].
Rietveld, PJM ;
Lumori, MLD ;
van der Zee, J ;
van Rhoon, GC .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2207-2220
[24]   Effectiveness of FDTD in predicting SAR distributions from the lucite cone applicator [J].
Samaras, T. ;
Rietveld, P.J.M. ;
van Rhoon, G.C. .
IEEE Transactions on Microwave Theory and Techniques, 2000, 48 (11 II) :2059-2063
[25]   ELECTROMAGNETIC HEATING OF TISSUE-EQUIVALENT PHANTOMS WITH THIN, INSULATING PARTITIONS [J].
SCHAUBERT, DH .
BIOELECTROMAGNETICS, 1984, 5 (02) :221-232
[26]   Relationship between thermal dose and outcome in thermoradiotherapy treatments for superficial recurrences of breast cancer: Data from a phase III trial [J].
Sherar, M ;
Liu, FF ;
Pintilie, M ;
Levin, W ;
Hunt, J ;
Hill, R ;
Hand, J ;
Vernon, C ;
vanRhoon, G ;
vanderZee, J ;
Gonzalez, DG ;
vanDijk, J ;
Whaley, J ;
Machin, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02) :371-380
[27]   Characterisation of Ex Vivo Liver Thermal Properties for Electromagnetic-Based Hyperthermic Therapies [J].
Silva, Nuno P. ;
Bottiglieri, Anna ;
Conceicao, Raquel C. ;
O'Halloran, Martin ;
Farina, Laura .
SENSORS, 2020, 20 (10)
[28]   Quality assurance guidelines for interstitial hyperthermia [J].
Trefna, H. Dobsicek ;
Schmidt, M. ;
van Rhoon, G. C. ;
Kok, H. P. ;
Gordeyev, S. S. ;
Lamprecht, U. ;
Marder, D. ;
Nadobny, J. ;
Ghadjar, P. ;
Abdel-Rahman, S. ;
Kukielka, A. M. ;
Strnad, V. ;
Hurwitz, M. D. ;
Vujaskovic, Z. ;
Diederich, C. J. ;
Stauffer, P. R. ;
Crezee, J. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (01) :277-294
[29]  
Trefná HD, 2017, STRAHLENTHER ONKOL, V193, P351, DOI 10.1007/s00066-017-1106-0
[30]   Development of a guideline for the water bolus temperature in superficial hyperthermia [J].
Van der Gaag, M. L. ;
de Bruijne, M. ;
Samaras, T. ;
Van der Zee, J. ;
Van Rhoon, G. C. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2006, 22 (08) :637-656