On-Chip Nucleic Acid Purification Followed by ddPCR for SARS-CoV-2 Detection

被引:3
作者
Ma, Cong [1 ,2 ,3 ]
Sun, Yimeng [2 ,3 ]
Huang, Yuhang [2 ,4 ]
Gao, Zehang [2 ,5 ]
Huang, Yaru [2 ,4 ]
Pandey, Ikshu [6 ]
Jia, Chunping [2 ,3 ]
Feng, Shilun [2 ,3 ]
Zhao, Jianlong [2 ,3 ,7 ]
机构
[1] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Univ Chinese Acad Sci, Ctr Mat Sci & Optoelect Engn, Beijing 100049, Peoples R China
[4] Shanghai Normal Univ, Sch Life Sci, Shanghai 200235, Peoples R China
[5] Guangzhou Med Univ, Dept Clin Lab, Affiliated Hosp 3, Guangzhou 510150, Peoples R China
[6] Johns Hopkins Univ, Dept Mat Sci & Engn, Baltimore, MD 21218 USA
[7] Xiangfu Lab, Jiaxing 314102, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 05期
基金
中国博士后科学基金;
关键词
nucleic acid purification; droplet generation; ddPCR; SARS-CoV-2; DIGITAL PCR; DNA; DEVICE;
D O I
10.3390/bios13050517
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a microfluidic chip integrated with nucleic acid purification and dropletbased digital polymerase chain reaction (ddPCR) modules to realize a `sample-in, result-out' infectious virus diagnosis. The whole process involved pulling magnetic beads through drops in an oilenclosed environment. The purified nucleic acids were dispensed into microdroplets by a concentricring, oil-water-mixing, flow-focusing droplets generator driven under negative pressure conditions. Microdroplets were generated with good uniformity (CV = 5.8%), adjustable diameters (50-200 mu m), and controllable flow rates (0-0.3 mu L/s). Further verification was provided by quantitative detection of plasmids. We observed a linear correlation of R-2 = 0.9998 in the concentration range from 10 to 10(5) copies/ mu L. Finally, this chip was applied to quantify the nucleic acid concentrations of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The measured nucleic acid recovery rate of 75 +/- 8.8% and detection limit of 10 copies/ mu L proved its on-chip purification and accurate detection abilities. This chip can potentially be a valuable tool in point-of-care testing.
引用
收藏
页数:13
相关论文
共 42 条
[1]   Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics [J].
Ali, Nasir ;
Pontello Rampazzo, Rita de Cassia ;
Tavares Costa, Alexandre Dias ;
Krieger, Marco Aurelio .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[2]   Recent Advances in Droplet-based Microfluidic Technologies for Biochemistry and Molecular Biology [J].
Barea, Joel Sanchez ;
Lee, Juhwa ;
Kang, Dong-Ku .
MICROMACHINES, 2019, 10 (06)
[3]   Surfactants in droplet-based microfluidics [J].
Baret, Jean-Christophe .
LAB ON A CHIP, 2012, 12 (03) :422-433
[4]   Accuracy of a RT-qPCR SARS-CoV-2 detection assay without prior RNA extraction [J].
Beltran-Pavez, Carolina ;
Alonso-Palomares, Luis A. ;
Valiente-Echeverria, Fernando ;
Gaggero, Aldo ;
Soto-Rifo, Ricardo ;
Barriga, Gonzalo P. .
JOURNAL OF VIROLOGICAL METHODS, 2021, 287
[5]   One-step purification of nucleic acid for gene expression analysis via Immiscible Filtration Assisted by Surface Tension (IFAST) [J].
Berry, Scott M. ;
Alarid, Elaine T. ;
Beebe, David J. .
LAB ON A CHIP, 2011, 11 (10) :1747-1753
[6]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[7]   False-positive results and contamination in nucleic acid amplification assays: Suggestions for a prevent and destroy strategy [J].
Borst, A ;
Box, ATA ;
Fluit, AC .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2004, 23 (04) :289-299
[8]   Highly efficient DNA extraction and purification from olive oil on a washable and reusable miniaturized device [J].
Carvalho, Joana ;
Puertas, Gema ;
Gaspar, Joao ;
Azinheiro, Sarah ;
Dieguez, Lorena ;
Garrido-Maestu, Alejandro ;
Vazquez, Manuel ;
Barros-Velazquez, Jorge ;
Cardoso, Susana ;
Prado, Marta .
ANALYTICA CHIMICA ACTA, 2018, 1020 :30-40
[9]   Super-Resolution Lensless Imaging of Cells Using Brownian Motion [J].
Fang, Yuan ;
Yu, Ningmei ;
Jiang, Yuquan .
APPLIED SCIENCES-BASEL, 2019, 9 (10)
[10]   Point-of-Care PCR Assays for COVID-19 Detection [J].
Gupta, Niharika ;
Augustine, Shine ;
Narayan, Tarun ;
O'Riordan, Alan ;
Das, Asmita ;
Kumar, D. ;
Luong, John H. T. ;
Malhotra, Bansi D. .
BIOSENSORS-BASEL, 2021, 11 (05)