Quantification of Cerebral Glucose Concentrations via Detection of the H1-α-Glucose Peak in 1H MRS at 7 T

被引:0
作者
Kuribayashi, Hideto [1 ,6 ]
Urushibata, Yuta [1 ]
Imai, Hirohiko [2 ]
Ahn, Sinyeob [3 ]
Seethamraju, Ravi Teja [4 ]
Isa, Tadashi [5 ]
Okada, Tomohisa [5 ]
机构
[1] Siemens Healthcare KK, Tokyo, Japan
[2] Kyoto Univ, Grad Sch Informat, Kyoto, Japan
[3] Siemens Med Solut, Berkeley, CA USA
[4] Siemens Med Solut, Boston, MA USA
[5] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Kyoto, Japan
[6] Siemens Healthcare KK, 1-11-1 Osaki Shinagawa ku, Tokyo 1430012, Japan
关键词
7 T-baseline correction; brain glucose concentration; H1-alpha-glucose; LCModel; magnetic resonance spectroscopy; VIVO H-1-NMR SPECTROSCOPY; HUMAN BRAIN; NEUROCHEMICAL PROFILE; TIME; TRANSPORT; SPECTRA; SIMULATIONS; RATES; WATER;
D O I
10.1002/jmri.28834
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Sensitive detection and quantification of cerebral glucose is desired. Purpose: To quantify cerebral glucose by detecting the H1-alpha-glucose peak at 5.23 ppm in 1H magnetic resonance spectroscopy at 7 T. Study Type: Prospective. Subjects: Twenty-eight non-fasted healthy subjects (aged 20-28 years). Field Strength/Sequence: Short echo time stimulated echo acquisition mode (short-TE STEAM) and semi-localized by adiabatic selective refocusing (semi-LASER) at 7 T. Assessment: Single voxel spectra were obtained from the posterior cingulate cortex (27-mL) using a 32-channel head coil. The H1-alpha-glucose peak in the spectrum with retrospective removal of the residual water peak was fitted using LCModel with a glucose basis set of only the H1-alpha-glucose peak. Conventional spectral analysis was performed with a glucose basis set of a full spectral pattern of glucose, also. Fitting precision was evaluated with Cramer-Rao lower bounds (CRLBs). The repeatability of glucose quantification via the semi-LASER sequence was tested. Statistical Tests: Paired or Welch's t-test were used for normally distributed values. A P value of <0.05 was considered significant. The repeatability of measures was analyzed using coefficient of variation (CV). Results: Removal of the residual water peak improved the flatness and stability of baselines around the H1-alpha-glucose peak and reduced CRLBs for fitting the H1-alpha-glucose peak. The semi-LASER sequence was superior to the short-TE STEAM in the higher signal-to-noise ratio of the H1-alpha-glucose peak (mean +/- SD 7.9 +/- 2.5, P < 0.001). The conventional analysis overfitted the H1-alpha-glucose peak. The individual CVs of glucose quantification by detecting the H1-alpha-glucose peak were smaller than the corresponding CRLBs. Data Conclusion: Cerebral glucose concentration is quantitated to be 1.07 mM by detecting the H1-alpha-glucose peak in the semi-LASER spectra. Despite requiring long scan times, detecting the H1-alpha-glucose peak allows true glucose quantification free from the influence of overlapping taurine and macromolecule signals. Evidence Level: 2 Technical Efficacy Stage: 1
引用
收藏
页码:661 / 672
页数:12
相关论文
共 43 条
[1]   Influence of macromolecule baseline on 1H MR spectroscopic imaging reproducibility [J].
Birch, Rebecca ;
Peet, Andrew C. ;
Dehghani, Hamid ;
Wilson, Martin .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :34-43
[2]   Integrating 1H MRS and deuterium labeled glucose for mapping the dynamics of neural metabolism in humans [J].
Cember, Abigail T. J. ;
Wilson, Neil E. ;
Rich, Laurie J. ;
Bagga, Puneet ;
Nanga, Ravi Prakash Reddy ;
Swago, Sophia ;
Swain, Anshuman ;
Thakuri, Deepa ;
Elliot, Mark ;
Schnall, Mitchell D. ;
Detre, John A. ;
Reddy, Ravinder .
NEUROIMAGE, 2022, 251
[3]  
de Graaf R.A., 2007, IN VIVO NMR SPECTROS
[4]   Differentiation of glucose transport in human brain gray and white matter [J].
de Graaf, RA ;
Pan, JW ;
Telang, F ;
Lee, JH ;
Brown, P ;
Novotny, EJ ;
Hetherington, HP ;
Rothman, DL .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2001, 21 (05) :483-492
[5]   Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times [J].
Dehghani, Masoumeh ;
Do, Kim Q. ;
Magistretti, Pierre ;
Xin, Lijing .
MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) :1895-1908
[6]  
Duarte JM., 2012, Neural Metabolism In Vivo, vol, V4, P655
[7]   In vivo characterization of the downfield part of 1H MR spectra of human brain at 9.4 T: Magnetization exchange with water and relation to conventionally determined metabolite content [J].
Fichtner, Nicole D. ;
Giapitzakis, Ioannis-Angelos ;
Avdievich, Nikolai ;
Mekle, Ralf ;
Zaldivar, Daniel ;
Henning, Anke ;
Kreis, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :2863-2873
[8]   Elucidation of the downfield spectrum of human brain at 7T using multiple inversion recovery delays and echo times [J].
Fichtner, Nicole D. ;
Henning, Anke ;
Zoelch, Niklaus ;
Boesch, Chris ;
Kreis, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) :11-19
[9]   Use of tissue water as a concentration reference for proton spectroscopic imaging [J].
Gasparovic, Charles ;
Song, Tao ;
Devier, Deidre ;
Bockholt, H. Jeremy ;
Caprihan, Arvind ;
Mullins, Paul G. ;
Posse, Stefan ;
Jung, Rex E. ;
Morrison, Leslie A. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1219-1226
[10]  
Govindaraju V, 2000, NMR BIOMED, V13, P129, DOI 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO