Impact of Reconstructing Intercostal Artery on Spinal Cord Circulation During Open Surgery for Thoracoabdominal Aortic Aneurysm

被引:3
作者
Kobayashi, Kei [1 ,2 ]
Saito, Satoshi [1 ]
机构
[1] Tokyo Womens Med Univ, Heart Inst Japan, Dept Cardiovasc Surg, Tokyo, Japan
[2] Tokyo Womens Med Univ, Heart Inst Japan, Dept Cardiovasc Surg, 8-1,Kawada Cho, Tokyo 1628666, Japan
关键词
Aortic Aneurysm; Thoracic; Arteries; Cerebrospinal; Fluid Leak; Evoked Potentials; Motor; General Surgery; Hospitals; Hypothermia; Spinal Cord Injuries; Mortality; ADAMKIEWICZ ARTERY; COLLATERAL NETWORK; REDUCES PARAPLEGIA; FLUID DRAINAGE; REPAIR; BYPASS; PROTECTION;
D O I
10.21470/1678-9741-2021-0219
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: We evaluated the outcomes of the selective intercostal artery reconstruction for preventing spinal cord injury during thoracoabdominal aortic aneurysm repair. Methods: We retrospectively assessed 84 consecutive patients who underwent thoracoabdominal aortic aneurysm repairs between 2004 and 2016. The mean age of the patients was 57.3 years. We performed preoperative multidetector computed tomography in 74 patients (88.0%) to identify the Adamkiewicz artery. Spinal cord injury preventive measures included motor evoked potential monitoring, hypothermia induction, Adamkiewicz artery or other intercostal artery reconstruction, and cerebrospinal fluid drainage. Results: The hospital death rate was 5.9%, and paraplegia occurred in four patients (4.7%). The Adamkiewicz artery or other intercostal arteries were reconstructed selectively in 46 patients (54.7%). Of these patients, 41 underwent postoperative multidetector computed tomography, which revealed occlusion of the reconstructed grafts in 23 patients (56.0%). There was no paraplegia in the patients who underwent reconstruction of the Adamkiewicz artery, which was patent on postoperative multidetector computed tomography. Univariate analysis showed no significant effect of various risk factors on the development of spinal cord injury. Conclusion: Outcome of open surgery for thoracoabdominal aortic aneurysm in our institution regarding spinal cord injury was satisfactory. The benefits of Adamkiewicz artery reconstruction remain inconclusive, and further larger studies are required to identify its validation for spinal cord protection in thoracoabdominal aortic aneurysm repair.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 25 条
  • [1] Intercostal artery management in thoracoabdominal aortic surgery: To reattach or not to reattach?
    Afifi, Rana O.
    Sandhu, Harleen K.
    Zaidi, Syed T.
    Trinh, Ernest
    Tanaka, Akiko
    Miller, Charles C., III
    Safi, Hazim J.
    Estrera, Anthony L.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (04) : 1372 - +
  • [2] Cercbrospinal fluid drainage to prevent paraplegia during thoracic and thoracoabdominal aortic aneurysm surgery:: A systematic review and meta-analysis
    Cinà, CS
    Abouzahr, L
    Arena, GO
    Laganà, A
    Devereaux, PJ
    Farrokhyar, F
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 40 (01) : 36 - 44
  • [3] Left heart bypass reduces paraplegia rates after thoracoabdominal aortic aneurysm repair
    Coselli, JS
    LeMaire, SA
    [J]. ANNALS OF THORACIC SURGERY, 1999, 67 (06) : 1931 - 1934
  • [4] Cerebrospinal fluid drainage reduces paraplegia after thoracoabdominal aortic aneurysm repair:: Results of a randomized clinical trial
    Coselli, JS
    LeMaire, SA
    Köksoy, C
    Schmittling, ZC
    Curling, PE
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 35 (04) : 631 - 639
  • [5] Thoracoabdominal aortic aneurysm repair: Review and update of current strategies
    Coselli, JS
    Conklin, LD
    LeMaire, SA
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (05) : S1881 - S1884
  • [6] de Haan P, 1998, Semin Thorac Cardiovasc Surg, V10, P19
  • [7] Thoracic and thoracoabdominal aneurysm repair: Is reimplantation of spinal cord arteries a waste of time?
    Etz, Christian D.
    Halstead, James C.
    Spielvogel, David
    Shahani, Rohit
    Lazala, Ricardo
    Homann, Tobias M.
    Weisz, Donald J.
    Plestis, Konstadinos
    Griepp, Randall B.
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (05) : 1670 - 1678
  • [8] The collateral network concept: Remodeling of the arterial collateral network after experimental segmental artery sacrifice
    Etz, Christian D.
    Kari, Fabian A.
    Mueller, Christoph S.
    Brenner, Robert M.
    Lin, Hung-Mo
    Griepp, Randall B.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04) : 1029 - 1036
  • [9] Spinal cord perfusion and protection during descending thoracic and thoracoabdominal aortic surgery: The collateral network concept
    Griepp, Randall B.
    Griepp, Eva B.
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (02) : S865 - S869
  • [10] Assessment of spinal cord integrity during thoracoabdominal aortic aneurysm repair
    Jacobs, MJ
    Elenbaas, TW
    Schurink, GWH
    Mess, WH
    Mochtar, B
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (05) : S1864 - S1866