共 50 条
Experimental and Finite Element Study on the Shear Performance of Existing Super-Span Concrete T-Beams Retrofitted with Glass Fiber-Reinforced Plastic
被引:3
|作者:
Hou, Dongxu
[1
]
Hu, Tieming
[1
]
Zhang, Guanhua
[2
]
机构:
[1] Shenyang Univ, Construct Engn Dept, Shenyang 110044, Peoples R China
[2] Liaoning Prov Transportat Planning & Design Inst C, Shenyang 110057, Peoples R China
关键词:
T-beam;
glass fiber-reinforced plastic;
retrofitted;
shear performance;
failure mechanism;
finite element analysis;
SECTION BEAMS;
CAPACITY;
BEHAVIOR;
POLYMER;
STRENGTH;
FAILURE;
D O I:
10.3390/su15032768
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Super-span, reinforced concrete, T-shaped cross-section beams (T-beams) with a service life of more than 30 years are widely used in highway bridges in China. Most of these beams have been retrofitted with glass fiber-reinforced plastic (GFRP) to prevent performance degradation. However, the actual shear performance, ultimate state, and failure mechanism of the existing retrofitted super-span concrete T-beams are currently unclear for many inextricable problems. To fill these gaps, in this study, one super-span concrete T-beam, in service for 31 years and retrofitted with GFRP, was extracted from a highway bridge to conduct shear experimentation in a structural laboratory. To assess the particularity of the specimen, finite element analysis was also conducted using ABAQUS software as a supplement to the shear tests. The failure procedure of the specimen was investigated, and the influence of the loading mode on the shear performance of a super-long and old T-beam was also studied. It is concluded that the failure of the super-span T-beam begins with small cracks at the bottom of the mid-span, rather than a loading point.
引用
收藏
页数:18
相关论文