Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems

被引:1
作者
Fusch, Gerhard [1 ]
Mohamed, Saber [2 ]
Bakry, Ahmad [1 ]
Li, Edward W. [1 ]
Dutta, Sourabh [1 ,3 ]
Helou, Salhab el [1 ]
Fusch, Christoph [1 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Div Neonatol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[3] Postgrad Inst Med Educ & Res PGIMER, Dept Pediat, Neonatal Unit, Chandigarh, India
[4] Paracelsus Med Univ Nuremberg, Dept Pediat, Nurnberg, Germany
关键词
Sound pressure; Occupational noise; Environmental exposure; Disorders of environmental origin; SOUND LEVELS; WARD; ROOM;
D O I
10.1007/s00431-023-05335-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Reorganization of neonatal intensive care by introducing clinical microsystems may help to allocate nursing time more appropriately to the needs of patients. However, there is concern that cohorting infants according to acuity may enhance noise levels. This single-center study investigated the impact of reorganization of neonatal intensive care unit by implementing clinical microsystems in a Level III NICU on environmental noise. This prospective study measured 24-h noise levels over a period of 6 months during pre- and post-implementation of microsystems cohorting infants of similar acuity. Comparative analyses of the mixed acuity (i.e., before) and the cohorting (i.e., after) model were performed by creating daily profiles from continuous noise level measurements and calculating the length of exposure to predefined noise levels. Compared to baseline daytime measurements, noise levels were 3-6 dBA higher during physician handover. Noise levels were 2-3 dBA lower on weekends and 3-4 dBA lower at night, independent of the organizational model. The introduction of clinical microsystems slightly increased average noise levels for high-acuity pods (A and B) but produced a much more substantial decrease for low-acuity pods (E), leading to an overall reduction in unit-wide noise levels. Conclusion: Our data show that noise levels are more driven by human behavior than by technical devices. Implementation of microsystems may help to reduce noise exposure in the lower acuity pods in a NICU.What is Known:center dot Excessive noise levels can lead to adverse effects on the health and development of premature infants and other critically ill newborns.center dot The reorganization of the neonatal intensive care unit following the clinical microsystems principles might improve quality of care but also affect noise exposure of staff and patients.What is New:center dot The transition from a mixed -acuity to cohorting model is associated with an overall reduction in noise levels, particularly in low-acuity pods requiring less nursing care.center dot Nevertheless, baseline noise levels in both models exceeded the standard permissible limits.
引用
收藏
页码:1245 / 1254
页数:10
相关论文
共 27 条
  • [21] Comparing sound measurements in the single-family room with open-unit design neonatal intensive care unit: the impact of equipment noise
    Liu, W. F.
    [J]. JOURNAL OF PERINATOLOGY, 2012, 32 (05) : 368 - 373
  • [22] A Comparison of Sound Levels in Open Plan Versus Pods in a Neonatal Intensive Care Unit
    Ramm, Karlie
    Mannix, Trudi
    Parry, Yvonne
    Gaffney, Mary P.
    [J]. HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2017, 10 (03) : 30 - 39
  • [23] Newborn Incubators Do Not Protect from High Noise Levels in the Neonatal Intensive Care Unit and Are Relevant Noise Sources by Themselves
    Restin, Tanja
    Gaspar, Mikael
    Bassler, Dirk
    Kurtcuoglu, Vartan
    Scholkmann, Felix
    Haslbeck, Friederike Barbara
    [J]. CHILDREN-BASEL, 2021, 8 (08):
  • [24] Validation of a tool to measure neonatal nursing workload
    Sawatzky-Dickson, Doris
    Bodnaryk, Karen
    [J]. JOURNAL OF NURSING MANAGEMENT, 2009, 17 (01) : 84 - 91
  • [25] Reorganizing a Hospital Ward as an Accountable Care Unit
    Stein, Jason
    Payne, Christina
    Methvin, Amanda
    Bonsall, Joanna M.
    Chadwick, Liam
    Clark, Diaz
    Castle, Bryan W.
    Tong, David
    Dressler, Daniel D.
    [J]. JOURNAL OF HOSPITAL MEDICINE, 2015, 10 (01) : 36 - 40
  • [26] Comparison of Private Room With Multiple-Bed Ward Neonatal Intensive Care Unit Environments
    Van Enk, Richard A.
    Steinberg, Florence
    [J]. HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2011, 5 (01) : 52 - 63
  • [27] Impact of a participatory program to reduce noise in a Neonatal Unit
    Zamberlan-Amorim, Nelma Ellen
    Fujinaga, Cristina Ide
    Hass, Vanderlei Jose
    Monti Fonseca, Luciana Mara
    Fortuna, Cinira Magali
    Silvan Scochi, Carmen Gracinda
    [J]. REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2012, 20 (01) : 109 - 116