Easy determination of benzophenone and its derivatives in sunscreen samples by direct-immersion solid-phase microextraction and gas chromatography-mass spectrometry

被引:4
|
作者
Rascon, Andres J. [1 ,3 ]
Rocio-Bautista, Priscilla [1 ,3 ]
Palacios-Colon, Laura [2 ]
Ballesteros, Evaristo [2 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Analyt Chem Res Grp, Campus Las Lagunillas S-N, Jaen 23071, Spain
[2] Univ Jaen, Dept Phys & Analyt Chem, Analyt Chem Res Grp, Campus Cient Tecnol Linares S-N, Jean 23700, Spain
[3] Univ Jaen, Analyt Chem Res Grp, Jaen, Spain
关键词
Direct-immersion solid phase-microextraction; Gaschromatography-mass spectrometry; Benzophenones; Sunscreen; PERSONAL CARE PRODUCTS; UV FILTERS; HUMAN URINE; WATER; EXTRACTION; DERIVATIZATION; COSMETICS;
D O I
10.1016/j.jpba.2023.115711
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Benzophenones (BPs) absorb different sun radiation wavelengths, making them effective UVA and UVB filters, widely used in industry. In Europe, sunscreen products contain regulated amounts (6 % w/w) of benzophenone-3 (BP-3), usually combined with other filters like octocrylene. BPs are mutagens in UV radiation, and octocrylene may degrade into BPs, making their monitoring crucial. The present manuscript proposed a novel procedure based on liquid-liquid extraction followed by direct-immersion solid-phase microextraction (LLE-DI-SPME) to isolate and determine 10 BPs in sunscreen lotions with potential results. Parameters like extraction solvent, pH, adsorption, desorption time, stirring, sating effect, and presence of organic solvents were optimized and compared with different SPME fibers, being polyacrylate (PA) fiber the most effective. Detection and quantification were performed by gas chromatography-mass-spectrometry. Analytical parameters as limits of detection were 0.05-0.10 mu g kg-1, while the linear range was 0.16 up to 2000 mu g kg-1. In terms of recovery, the method ranged from 83 % to 103 %; the precision of the method was good in terms of relative standard deviation (RSD) from 3.2 % to 18.7 % and without a remarkable matrix effect (-15.06-8.45 %). Despite the complexity of the samples and the difficulty posed by the DI-SPME technique, the method proved robust. The proposed method successfully detected 10 BPs in 6 different sunscreen lotions. The total presence of BPs in sunscreens ranged from 165 to 931 mg kg-1, with BP-3 detected in all samples from 4.2 to 740 mg kg-1.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Determination of pesticides in tea by isotope dilution gas chromatography-mass spectrometry coupled with solid-phase microextraction
    Feng, Jie
    Tang, Hua
    Chen, Dazhou
    Wang, Guannan
    Li, Lei
    ANALYTICAL METHODS, 2012, 4 (12) : 4198 - 4203
  • [32] Effects of sample pretreatment and storage conditions in the determination of pyrethroids in water samples by solid-phase microextraction and gas chromatography-mass spectrometry
    Casas, Vanessa
    Llompart, Maria
    Garcia-Jares, Carmen
    Cela, Rafael
    Dagnac, Thierry
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1841 - 1849
  • [33] Headspace solid-phase microextraction and gas chromatography-mass spectrometry for determination of cannabinoids in human breast milk
    Silveira, Gabriela de Oliveira
    Loddi, Silvana
    Rodrigues de Oliveira, Carolina Dizioli
    Zucoloto, Alexandre Dias
    Gimenez Fruchtengarten, Ligia Veras
    Yonamine, Mauricio
    FORENSIC TOXICOLOGY, 2017, 35 (01) : 125 - 132
  • [34] Determination of the odorous compounds in the source of drinking water by solid-phase microextraction and gas chromatography-mass spectrometry
    Xu Na
    Liu Jing
    Liu Jianguang
    Wang Nan
    Lu Feng
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING (ICEESD2011), PTS 1-5, 2012, 356-360 : 951 - +
  • [35] Purge-assisted headspace solid-phase microextraction combined with gas chromatography-mass spectrometry for determination of chlorophenols in aqueous samples
    Ho, Hsin-Pin
    Lee, Ren-Jye
    Lee, Maw-Rong
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 245 - 248
  • [36] Determination of five synthetic musks in perfume by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Wang Guannan
    Tang Hua
    Chen Dazhou
    Feng Jie
    Li Lei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) : 135 - 140
  • [37] Fast determination of paeonol in plasma by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry
    Dong, Ling
    Deng, Chunhui
    Wang, Jiyao
    Shen, Xizhong
    ANALYTICA CHIMICA ACTA, 2007, 585 (01) : 76 - 80
  • [38] Determination of odorous compounds in water by headspace solid-phase microextraction-gas chromatography-mass spectrometry
    Li, L
    Song, LR
    Gan, NQ
    Chen, W
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (08) : 1058 - 1062
  • [39] Simultaneous determination of phenol, methylphenols, chlorophenols and bisphenol-A by headspace solid-phase microextraction-gas chromatography-mass spectrometry in water samples and industrial effluents
    Limam, Intissar
    Guenne, Angeline
    Driss, Mohamed Ridha
    Mazeas, Laurent
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (3-6) : 230 - 244
  • [40] Combined headspace single-drop microextraction and solid-phase microextraction for the determination of phenols as their methyl ethers by gas chromatography-mass spectrometry
    Jain, Archana
    Soni, Soumitra
    Reddy-Noone, Kishan
    Pillai, Aradhana K. K. V.
    Verma, Krishna K.
    ANALYTICAL METHODS, 2017, 9 (46) : 6590 - 6598