Radiation effects on scientific CMOS sensors for X-ray astronomy: I. Proton irradiation

被引:6
|
作者
Liu, Mingjun [1 ,2 ]
Ling, Zhixing [1 ,2 ]
Wu, Qinyu [1 ,2 ]
Zhang, Chen [1 ,2 ]
Liu, Jiaqiang [3 ]
Zhang, Zhenlong [2 ,3 ]
Yuan, Weimin [1 ,2 ]
Zhang, Shuang-Nan [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Natl Astron Observ, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Astron & Space Sci, Beijing, Peoples R China
[3] Chinese Acad Sci, Natl Space Sci Ctr, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
X-ray detector; CMOS sensor; proton irradiation; sensor performance; DAMAGE;
D O I
10.1117/1.JATIS.9.4.046003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the impact of irradiation on the performance of two scientific CMOS (sCMOS) sensors between -30 degrees C and 20 degrees C at high gain mode (7.5x), including the bias map, readout noise, dark current, conversion gain, and energy resolution. The two sensors are irradiated with 50 MeV protons with a total dose of 5.3 x 1010 p .cm(-2). After the exposure, the bias map, readout noise, and conversion gain at various temperatures are not significantly degraded, nor is the energy resolution at -30 degrees C. However, after the exposure the dark current has increased by hundreds of times, and for every 20 degrees C increase in temperature, the dark current also increases by an order of magnitude. Therefore, at room temperature, the fluctuations of the dark currents dominate the noise and lead to a serious degradation of the energy resolution. Moreover, among the 4 k x 4 k pixels, there are about 100 pixels whose bias at 50 ms has changed by more than 10 DN (similar to 18 e(-)), and about 10 pixels whose readout noise has increased by over 15 e(-) at -30 degrees C. Fortunately, the influence of the dark current can be reduced by decreasing the integration time, and the degraded pixels can be masked by regular analysis of the dark images. Some future X-ray missions will likely operate at -30 degrees C, under which the dark current is too small to significantly affect the X-ray performance. Our investigations show the high tolerance of the sCMOS sensors for proton radiation and prove their suitability for X-ray astronomy applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Soft x-ray resolution and scientific performance of CCD sensors for future x-ray missions
    LaMarr, Beverly J.
    Schneider, Benjamin
    Prigozhin, Gregory Y.
    Miller, Eric D.
    Bautz, Marshall W.
    Cooper, Michael J.
    Donlon, Kevan
    Foster, Richard F.
    Grant, Catherine E.
    Jensen, Mallory
    Lambert, Renee D.
    Leitz, Chris
    Malonis, Andrew C.
    Ryu, Kevin K.
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [32] BAT X-ray survey. I. Methodology and X-ray identification
    Ajello, M.
    Greiner, J.
    Kanbach, G.
    Rau, A.
    Strong, A. W.
    Kennea, J. A.
    ASTROPHYSICAL JOURNAL, 2008, 678 (01): : 102 - 115
  • [33] Design and test results of scientific X-ray CMOS cameras
    Wang, Wenxin
    Ling, Zhixing
    Zhang, Chen
    Wu, Qiong
    Jia, Zhenqing
    Wang, Xinyang
    Yuan, Weimin
    Zhang, Shuangnan
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY X, 2022, 12191
  • [34] Proton radiation hardness of x-ray SOI pixel sensors with pinned depleted diode structure
    Hayashida, Mitsuki
    Hagino, Kouichi
    Kohmura, Takayoshi
    Kitajima, Masatoshi
    Yarita, Keigo
    Oono, Kenji
    Negishi, Kousuke
    Tsuru, Takeshi G.
    Tanaka, Takaaki
    Uchida, Hiroyuki
    Kayama, Kazuho
    Kodama, Ryota
    Mori, Koji
    Takeda, Ayaki
    Nishioka, Yusuke
    Hida, Takahiro
    Yukumoto, Masataka
    Arai, Yasuo
    Kurachi, Ikuo
    Kitamura, Hisashi
    Kawahito, Shoji
    Yasutomi, Keita
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2021, 7 (03)
  • [35] Application of Naked Commercial CMOS Sensors to X-ray Fluorescence and. X-ray Beam Monitoring
    Castoldi, A.
    Guazzoni, C.
    Maffessanti, S.
    Montemurro, G. V.
    Carraresi, L.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [36] Effects of proton irradiation on structure of NdFeB permanent magnets studied by X-ray diffraction and X-ray absorption fine structure
    Yang, L.
    Zhen, L.
    Xu, C. Y.
    Sun, X. Y.
    Shao, W. Z.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2011, 323 (01) : 4 - 6
  • [37] STELLAR AND SOLAR X-RAY ASTRONOMY ON OSO-I
    COHEN, GG
    LANDECKE.PB
    NOVICK, R
    TORASKAR, JR
    WANG, JR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 531 - 531
  • [38] The effects of proton induced radiation damage on compound semiconductor X-ray detectors
    Owens, A
    Alha, L
    Andersson, H
    Bavdaz, M
    Brammertz, G
    Helariutta, K
    Peacock, A
    Lämsä, V
    Nenonen, S
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 403 - 411
  • [39] Study of X-ray radiation damage in silicon sensors
    Zhang, J.
    Fretwurst, E.
    Klanner, R.
    Perrey, H.
    Pintilie, I.
    Poehlsen, T.
    Schwandt, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [40] The relative costs of proton and X-ray radiation therapy
    Goitein, M
    Jermann, M
    CLINICAL ONCOLOGY, 2003, 15 (01) : S37 - S50