Radiation effects on scientific CMOS sensors for X-ray astronomy: I. Proton irradiation

被引:6
|
作者
Liu, Mingjun [1 ,2 ]
Ling, Zhixing [1 ,2 ]
Wu, Qinyu [1 ,2 ]
Zhang, Chen [1 ,2 ]
Liu, Jiaqiang [3 ]
Zhang, Zhenlong [2 ,3 ]
Yuan, Weimin [1 ,2 ]
Zhang, Shuang-Nan [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Natl Astron Observ, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Astron & Space Sci, Beijing, Peoples R China
[3] Chinese Acad Sci, Natl Space Sci Ctr, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
X-ray detector; CMOS sensor; proton irradiation; sensor performance; DAMAGE;
D O I
10.1117/1.JATIS.9.4.046003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the impact of irradiation on the performance of two scientific CMOS (sCMOS) sensors between -30 degrees C and 20 degrees C at high gain mode (7.5x), including the bias map, readout noise, dark current, conversion gain, and energy resolution. The two sensors are irradiated with 50 MeV protons with a total dose of 5.3 x 1010 p .cm(-2). After the exposure, the bias map, readout noise, and conversion gain at various temperatures are not significantly degraded, nor is the energy resolution at -30 degrees C. However, after the exposure the dark current has increased by hundreds of times, and for every 20 degrees C increase in temperature, the dark current also increases by an order of magnitude. Therefore, at room temperature, the fluctuations of the dark currents dominate the noise and lead to a serious degradation of the energy resolution. Moreover, among the 4 k x 4 k pixels, there are about 100 pixels whose bias at 50 ms has changed by more than 10 DN (similar to 18 e(-)), and about 10 pixels whose readout noise has increased by over 15 e(-) at -30 degrees C. Fortunately, the influence of the dark current can be reduced by decreasing the integration time, and the degraded pixels can be masked by regular analysis of the dark images. Some future X-ray missions will likely operate at -30 degrees C, under which the dark current is too small to significantly affect the X-ray performance. Our investigations show the high tolerance of the sCMOS sensors for proton radiation and prove their suitability for X-ray astronomy applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] X-ray optimised CMOS image sensors for the Auroral X-ray Imaging Spectrometer (AXIS)
    Crews, Chiaki
    Buggey, Thomas W.
    Jones, Lawrence S.
    Endicott, James
    Holland, Andrew D.
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [22] Comparison of X-Ray and Electron Radiation Effects on Dark Current Non-Uniformity and Fluctuations in CMOS Image Sensors
    Le Roch, Alexandre
    Virmontois, Cedric
    Paillet, Philippe
    Warner, Jeffrey H.
    Belloir, Jean-Marc
    Magnan, Pierre
    Goiffon, Vincent
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (01) : 268 - 277
  • [23] X-ray monochromators: I. Theory
    Mesropyan, MH
    Rostomyan, AH
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 2002, 231 (02): : 572 - 580
  • [24] X-RAY SCATTERING IN LIQUIDS .I.
    BEZIRGAN.PA
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1965, 9 (09): : 1282 - &
  • [25] Radiation effects of 0.18 μm CMOS APS by proton irradiation
    Cai Y.
    Li Y.
    Wen L.
    Feng J.
    Guo Q.
    Guo, Qi (GuoQi@ms.xjb.ac.c), 1600, Chinese Society of Astronautics (49):
  • [26] Radiation hardness of pn-CCDs for X-ray astronomy
    Meidinger, N
    Struder, L
    Soltau, H
    vonZanthier, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) : 2066 - 2073
  • [27] An experimental study of 1.5 keV X-ray radiation effects on CMOS devices
    Srivastava, A
    Nema, R
    Bhattacharya, PK
    MICROELECTRONICS AND RELIABILITY, 1996, 36 (03): : 323 - 333
  • [28] Development of arrays of transition edge sensors for application in X-ray astronomy
    Bruijn, MP
    Tiest, WMB
    Hoevers, HFC
    Krouwer, E
    van der Kuur, J
    Ridder, ML
    Moktadir, Z
    Wiegerink, R
    van Gelder, D
    Elwenspoek, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 143 - 146
  • [29] Development of an array of transition edge sensors for application in X-ray astronomy
    Bruijn, MP
    Baars, NHR
    Tiest, WMB
    Germeau, A
    Hoevers, HFC
    de Korte, PAJ
    Mels, WA
    Ridder, ML
    Krouwer, E
    van Baar, JJ
    Wiegerink, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 443 - 445
  • [30] THERMOLUMINESCENT RADIATION DOSIMETRY .I. X-RAY DOSE RECEIVED BY HUMAN OCULAR TISSUES DURING IRRADIATION OF EYELID CANCERS
    KOPF, AW
    GRISEWOO.EN
    BART, R
    PETRATOS, M
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1967, 48 (03) : 289 - &