Radiation effects on scientific CMOS sensors for X-ray astronomy: I. Proton irradiation

被引:6
作者
Liu, Mingjun [1 ,2 ]
Ling, Zhixing [1 ,2 ]
Wu, Qinyu [1 ,2 ]
Zhang, Chen [1 ,2 ]
Liu, Jiaqiang [3 ]
Zhang, Zhenlong [2 ,3 ]
Yuan, Weimin [1 ,2 ]
Zhang, Shuang-Nan [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Natl Astron Observ, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Astron & Space Sci, Beijing, Peoples R China
[3] Chinese Acad Sci, Natl Space Sci Ctr, Beijing, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
X-ray detector; CMOS sensor; proton irradiation; sensor performance; DAMAGE;
D O I
10.1117/1.JATIS.9.4.046003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the impact of irradiation on the performance of two scientific CMOS (sCMOS) sensors between -30 degrees C and 20 degrees C at high gain mode (7.5x), including the bias map, readout noise, dark current, conversion gain, and energy resolution. The two sensors are irradiated with 50 MeV protons with a total dose of 5.3 x 1010 p .cm(-2). After the exposure, the bias map, readout noise, and conversion gain at various temperatures are not significantly degraded, nor is the energy resolution at -30 degrees C. However, after the exposure the dark current has increased by hundreds of times, and for every 20 degrees C increase in temperature, the dark current also increases by an order of magnitude. Therefore, at room temperature, the fluctuations of the dark currents dominate the noise and lead to a serious degradation of the energy resolution. Moreover, among the 4 k x 4 k pixels, there are about 100 pixels whose bias at 50 ms has changed by more than 10 DN (similar to 18 e(-)), and about 10 pixels whose readout noise has increased by over 15 e(-) at -30 degrees C. Fortunately, the influence of the dark current can be reduced by decreasing the integration time, and the degraded pixels can be masked by regular analysis of the dark images. Some future X-ray missions will likely operate at -30 degrees C, under which the dark current is too small to significantly affect the X-ray performance. Our investigations show the high tolerance of the sCMOS sensors for proton radiation and prove their suitability for X-ray astronomy applications.
引用
收藏
页数:11
相关论文
共 36 条
  • [21] Peyrard PF, 2004, ESA SP PUBL, V536, P639
  • [22] The eROSITA X-ray telescope on SRG
    Predehl, P.
    Andritschke, R.
    Arefiev, V
    Babyshkin, V
    Batanov, O.
    Becker, W.
    Boehringer, H.
    Bogomolov, A.
    Boller, T.
    Borm, K.
    Bornemann, W.
    Braeuninger, H.
    Brueggen, M.
    Brunner, H.
    Brusa, M.
    Bulbul, E.
    Buntov, M.
    Burwitz, V
    Burkert, W.
    Clerc, N.
    Churazov, E.
    Coutinho, D.
    Dauser, T.
    Dennerl, K.
    Doroshenko, V
    Eder, J.
    Emberger, V
    Eraerds, T.
    Finoguenov, A.
    Freyberg, M.
    Friedrich, P.
    Friedrich, S.
    Fuermetz, M.
    Georgakakis, A.
    Gilfanov, M.
    Granato, S.
    Grossberger, C.
    Gueguen, A.
    Gureev, P.
    Haberl, F.
    Haelker, O.
    Hartner, G.
    Hasinger, G.
    Huber, H.
    Ji, L.
    Kienlin, A., V
    Kink, W.
    Korotkov, F.
    Kreykenbohm, I
    Lamer, G.
    [J]. ASTRONOMY & ASTROPHYSICS, 2021, 647
  • [23] Roth MM, 2023, Arxiv, DOI arXiv:2304.07121
  • [24] Characterization of gamma-ray-induced radiation effects on a commercial CMOS sensor for x-ray small satellites
    Roth, Tyler
    Tammes, Steve
    Kaaret, Philip
    DeRoo, Casey
    Packard, Colin M.
    [J]. JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2022, 8 (02)
  • [25] The European Photon Imaging Camera on XMM-Newton:: The pn-CCD camera
    Strüder, L
    Briel, U
    Dennerl, K
    Hartmann, R
    Kendziorra, E
    Meidinger, N
    Pfeffermann, E
    Reppin, C
    Aschenbach, B
    Bornemann, W
    Bräuninger, H
    Burkert, W
    Elender, M
    Freyberg, M
    Haberl, F
    Hartner, H
    Heuschmann, F
    Hippmann, H
    Kastelic, E
    Kemmer, S
    Kettenring, G
    Kink, W
    Krause, N
    Müller, S
    Oppitz, A
    Pietsch, W
    Popp, M
    Predehl, P
    Read, A
    Stephan, KH
    Stötter, D
    Trümper, J
    Holl, P
    Kemmer, J
    Soltau, H
    Stötter, R
    Weber, U
    Weichert, U
    von Zanthier, C
    Carathanassis, D
    Lutz, G
    Richter, RH
    Solc, P
    Böttcher, H
    Kuster, M
    Staubert, R
    Abbey, A
    Holland, A
    Turner, M
    Balasini, M
    [J]. ASTRONOMY & ASTROPHYSICS, 2001, 365 (01): : L18 - L26
  • [26] Design and test results of different aluminum coating layers on the sCMOS sensors for soft X-ray detection
    Wang, W. X.
    Ling, Z. X.
    Zhang, C.
    Yuan, W. M.
    Zhang, S. N.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (12)
  • [27] Characterization of a BSI sCMOS for soft X-ray imaging spectroscopy
    Wang, W. X.
    Ling, Z. X.
    Zhang, C.
    Jia, Z. Q.
    Wang, X. Y.
    Wu, Q.
    Yuan, W. M.
    Zhang, S. N.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14 (02)
  • [28] Design and test results of scientific X-ray CMOS cameras
    Wang, Wenxin
    Ling, Zhixing
    Zhang, Chen
    Wu, Qiong
    Jia, Zhenqing
    Wang, Xinyang
    Yuan, Weimin
    Zhang, Shuangnan
    [J]. X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY X, 2022, 12191
  • [29] Developments of scientific CMOS as focal plane detector for Einstein Probe mission
    Wang, Wenxin
    Ling, Zhixing
    Zhang, Chen
    Wang, Xinyang
    Wu, Qiong
    Jia, Zhenqing
    Yuan, Weimin
    Zhang, Shuangnan
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [30] Charge transfer inefficiency increase of the CCD detector induced by proton and neutron irradiations
    Wang, Zujun
    Xue, Yuanyuan
    Xu, Rui
    Ning, Hao
    Jiao, Qianli
    Li, Junwei
    Ding, Lili
    Jia, Tongxuan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978