Experimental study on longitudinal shear behavior of prefabricated steel-concrete composite beams with notched connections

被引:6
作者
Huang, Da [1 ]
Nie, Xin [1 ]
Fan, Jiansheng [1 ]
Ding, Ran [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel-concrete composite bridge; Partial-depth precast panel system; Notched connection; Longitudinal shear capacity; Transverse reinforcement ratio; DESIGN;
D O I
10.1016/j.engstruct.2023.117151
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To address the fit-up issues caused by the interference between shear connectors and extended transverse bars, a novel deck-to-girder connection detail, notched connection, is applied to steel-concrete composite bridges with partial-depth deck panel (PDDP) systems. In the novel joint detail, protruding transverse reinforcement is replaced by evenly distributed notches at the ends of precast panels, and tie bars inserted in the notches are anticipated to resist longitudinal shear stress, achieving shear connection between steel girders and precast deck slabs. Considering the discontinuity of bottom transverse reinforcement, a four-point bending test was performed to investigate the longitudinal shear behavior of composite beams incorporating notched connections. Experimental findings indicate that the configuration of transverse reinforcement critically influences the failure modes of composite specimens, which involve crushing of concrete slabs, longitudinal shear cracking and splitting. Notably, tie bars sufficiently anchored in notches function equivalently to extended bars spliced by welding, and the specifically designed U-shaped notches enhance the anchorage performance of tie bars. Transverse reinforcing bars placed in the concrete topping prove more effective in resisting longitudinal shear than those in the bottom layer, and therefore asymmetrically reinforced concrete slabs experience reduced longitudinal shear cracking and splitting. Moreover, interface shear reinforcement effectively ensures the full composite action, while concentrated point loads can induce excessive local longitudinal shear stress. The study also provides design recommendations for notched connections.
引用
收藏
页数:18
相关论文
共 43 条
  • [1] ACI, 2014, ACI 318-14, DOI DOI 10.14359/51716937
  • [2] [Anonymous], 2015, JGJ 1-2014.
  • [3] [Anonymous], 2002, GB/T 10433-2002
  • [4] [Anonymous], 2016, JGJ 138-2016
  • [5] [Anonymous], 2010, GB 50010 - 2010, V2015
  • [6] [Anonymous], 2004, EN 1994-1-1
  • [7] [Anonymous], 2017, GB 50017-2017
  • [8] [Anonymous], 2007, AASHTO LRFD bridge design specifications, V4th
  • [9] [Anonymous], 2013, FIB FIB MODEL CODE C
  • [10] Load-Strain Model for Steel-Concrete-FRP-Concrete Columns in Axial Compression
    Cheng, Shi
    Feng, Peng
    Bai, Yu
    Ye, Lie Ping
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (05)