Detection of Signal of Fire Source for Coal Spontaneous Combustion Applied with Acoustic Wave

被引:6
作者
Ren, Shuaijing [1 ,2 ]
Zhang, Yanni [1 ,3 ]
Xiao, Yang [1 ,3 ]
Deng, Jun [1 ,3 ]
Ma, Teng [1 ,2 ]
Zhang, Yutao [1 ,3 ]
机构
[1] Xian Univ Sci & Technol, Sch Safety Sci & Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[2] Xian Univ Sci & Technol, Sch Energy Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[3] Xian Univ Sci & Technol, Shaanxi Key Lab Prevent & Control Coal Fire, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Coal spontaneous combustion; Fire source detection; Acoustic wave; Sound source signal; Cross-correlation; TEMPERATURE DISTRIBUTION; GASES; FLOW; RECONSTRUCTION; MINE;
D O I
10.1007/s11053-023-10225-0
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Coal spontaneous combustion can cause a series of problems in terms of wasted resources, casualties, and environmental pollution. Accurate detection of the fire source in loose coal is the key to preventing coal spontaneous combustion. Acoustic temperature measurement has significant advantages of strong stability, high accuracy, and wide measurement range, which can make up for the shortcomings of traditional fire source detection methods. Detecting the optimum source signal for loose coal temperature measurement is the basis and prerequisite for the realization of acoustic temperature measurement. Therefore, the anti-interference characteristics of three typical sound source signals were tested and analyzed through a self-designed sound wave propagation characteristic test system. The cross-correlations among maximum length sequence signal, pulse signal, and linear sweep signal were compared and analyzed. Compared to the other two signals, the main peak of the cross-correlation coefficient of the linear sweep signal was more prominent and its pseudo-peaks interfered less with its main peak. This signal had strong anti-interference ability, and it can be used as a basic acoustic source signal for temperature measurement of loose coal. To further screen out the optimal frequency band and length of the linear sweep signal, four bituminous coals were selected as the propagation medium. The main peak value and the difference between the main peak and the maximum pseudo-peak of the cross-correlation coefficient were proposed as the evaluation indicators. The optimum signal frequency bands of long-flame coal, non-caking coal, coking coal, and lean coal were 400-900, 400-900, 500-1200, and 400-900 Hz, and the optimum signal length of four coals was 0.1 s. The study results can provide theoretical support for the selection of acoustic temperature measurement signals for loose coal.
引用
收藏
页码:2243 / 2256
页数:14
相关论文
共 32 条
  • [31] Annual Change Detection by ASTER TIR Data and an Estimation of the Annual Coal Loss and CO2 Emission from Coal Seams Spontaneous Combustion
    Du, Xiaomin
    Peng, Suping
    Wang, Haiyan
    Bernardes, Sergio
    Yang, Guang
    Li, Zhipeng
    REMOTE SENSING, 2015, 7 (01): : 319 - 341
  • [32] A comprehensive method to prevent top-coal spontaneous combustion utilizing dry ice as a fire extinguishing medium: test apparatus development and field application
    Yueping Qin
    Wenjie Guo
    Hao Xu
    Yipeng Song
    Youqiang Chen
    Liwei Ma
    Environmental Science and Pollution Research, 2022, 29 : 19741 - 19751