Parametric optimization and modeling of continuous electrocoagulation process for the removal of fluoride: Response surface methodology and machine learning approach

被引:1
|
作者
Indurkar, Pankaj D. [1 ,2 ]
Raj, Savan K. [1 ]
Kulshrestha, Vaibhav [1 ,2 ]
机构
[1] CSIR Cent Salt & Marine Chem Res Inst, Membrane Sci & Separat Technol Div, GB Marg, Bhavnagar 364002, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
关键词
Electrocoagulation; Fluoride; Modeling; Central composite design; Machine learning; DRINKING-WATER; GROUNDWATER; REACTOR;
D O I
10.1007/s11696-023-03229-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The main objective of this study was to assess the continuous electrocoagulation process effectiveness for removing fluoride from potable water. The effect of different parameters like applied potential, electrode spacing, and feed flow rate was optimized for the continuous removal of fluoride from potable water. Response surface methodology (RSM) was used to examine the impact on essential operational factors such as voltage, concentration, and pH for fluoride removal as a response. The results demonstrate that all the parameters had a significant effect on removal efficiency. The quadratic model accurately predicted the optimal parameters for maximal fluoride removal efficiency with the association of desirability 1.0, which was discovered to be voltage 2.38 V, feed concentration 5.52 mg/L, and pH 6.45. According to the analysis of variance, R2 of the proposed quadratic model is higher (0.9877). Moreover, the difference between the predicted R2 of 0.9258 and the adjusted R2 of 0.9767 was less than 0.2. The model adequacy was also studied based on residual plot, perturbation plot, and box-cox plot. The RSM was best modeling techniques use to predict data than the multilayer perceptron and linear regression due to high accuracy. Finally, the generated flocs were characterized by scanning electron microscopy, energy-dispersive X-ray, X-ray diffraction, and Fourier transform infrared spectroscopy instrumental techniques. The outcomes demonstrate that a newly designed continuous electrocoagulation process is a promising alternative for the removal of fluoride from potable water.
引用
收藏
页码:1887 / 1896
页数:10
相关论文
共 50 条
  • [1] Parametric optimization and modeling of continuous electrocoagulation process for the removal of fluoride: Response surface methodology and machine learning approach
    Pankaj D. Indurkar
    Savan K. Raj
    Vaibhav Kulshrestha
    Chemical Papers, 2024, 78 : 2193 - 2212
  • [2] Arsenite removal from groundwater in a batch electrocoagulation process: Optimization through response surface methodology
    Demirbas, Erhan
    Kobya, Mehmet
    Oncel, Mehmet Salim
    Sik, Emrah
    Goren, Aysegul Yagmur
    SEPARATION SCIENCE AND TECHNOLOGY, 2019, 54 (05) : 775 - 785
  • [3] Enhanced fluoride removal by modified water hyacinth: response surface methodology and machine learning approach
    Patil, Jagadish H.
    Kusanur, Raviraj
    Hiremath, Poornima G.
    Gadagi, Amith H.
    Hegde, Prasad G.
    Deshannavar, Umesh B.
    BIOMASS CONVERSION AND BIOREFINERY, 2025,
  • [4] Techno-economical evaluation of fluoride removal by electrocoagulation process: Optimization through response surface methodology
    Behbahani, M.
    Moghaddam, M. R. Alavi
    Arami, M.
    DESALINATION, 2011, 271 (1-3) : 209 - 218
  • [5] PHOSPHATE REMOVAL BY ELECTROCOAGULATION PROCESS: OPTIMIZATION BY RESPONSE SURFACE METHODOLOGY METHOD
    Behbahani, Mohsen
    Moghaddam, Mohammad Reza Alavi
    Arami, Mokhtar
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2013, 12 (12): : 2397 - 2405
  • [6] Utilization of Response Surface Methodology in Electrocoagulation for Process Optimization and Parametric Analysis
    Akhtar, Adnan
    Suleman, Malik Shoaib
    Gillani, Syed Muzammil Awais
    Aslam, Zaheer
    CHEMBIOENG REVIEWS, 2024, 11 (01) : 136 - 152
  • [7] A study on continuous and batch electrocoagulation process for fluoride removal
    Lu, Jun
    Tang, Qing
    Wang, Zhong-Ru
    Xu, Chao
    Lin, Sheng-Ling
    DESALINATION AND WATER TREATMENT, 2016, 57 (58) : 28417 - 28425
  • [8] Optimization of the electrocoagulation process for sulfate removal using response surface methodology
    Hossini, Hooshyar
    Makhdoumi, Pouran
    Rastegar, Seyed Omid
    Mohammadi-Moghadam, Fazel
    Ghaffari, Hamid Reza
    Javid, Allahbakhsh
    Mirzaei, Nezam
    BULGARIAN CHEMICAL COMMUNICATIONS, 2015, 47 : 63 - 71
  • [9] Optimization of arsenic removal from drinking water by electrocoagulation batch process using response surface methodology
    Kobya, M.
    Demirbas, E.
    Gebologlu, U.
    Oncel, M. S.
    Yildirim, Y.
    DESALINATION AND WATER TREATMENT, 2013, 51 (34-36) : 6676 - 6687
  • [10] Techno-economic evaluation of simultaneous arsenic and fluoride removal from synthetic groundwater by electrocoagulation process: optimization through response surface methodology
    Thakur, Lokendra Singh
    Mondal, Prasenjit
    DESALINATION AND WATER TREATMENT, 2016, 57 (59) : 28847 - 28863