Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography

被引:39
作者
Hagar, Muhammad Taha [1 ]
Soschynski, Martin [1 ]
Saffar, Ruben [1 ]
Molina-Fuentes, Moises Felipe [1 ]
Weiss, Jakob [1 ]
Rau, Alexander [1 ]
Schuppert, Christopher [1 ]
Ruile, Philipp [2 ]
Faby, Sebastian [3 ]
Schibilsky, David [4 ]
von zur Muehlen, Constantin [2 ]
Schlett, Christopher L. [1 ]
Bamberg, Fabian [1 ]
Krauss, Tobias [1 ]
机构
[1] Univ Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Med Ctr, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Freiburg, Univ Hosp Freiburg,Heart Ctr, Fac Med, Dept Cardiol, Freiburg, Germany
[3] Siemens Healthcare GmbH, Computed Tomog, D-91301 Forchheim, Germany
[4] Freiburg Univ, Dept Cardiac & Vasc Surg, Freiburg, Germany
关键词
Computed tomography angiography; Stents; Coronary artery disease; Vascular patency; COMPUTED-TOMOGRAPHY; ASSOCIATION; SOCIETY;
D O I
10.1007/s00330-023-10516-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA).MethodsConsecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 x 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 ("excellent") to 5 ("non-diagnostic"), and assessed all coronary stents for the presence of in-stent stenosis (>= 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference.ResultsA total of 44 coronary stents in 18 participants (mean age, 83 years +/- 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen's kappa value of 0.72.ConclusionsUHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy.Clinical relevance statementUltra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis.Key Points center dot CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution.center dot Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography.center dot Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.Key Points center dot CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution.center dot Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography.center dot Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.Key Points center dot CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution.center dot Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography.center dot Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.
引用
收藏
页码:4273 / 4283
页数:11
相关论文
共 30 条
[1]   Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom [J].
Allmendinger, Thomas ;
Nowak, Tristan ;
Flohr, Thomas ;
Klotz, Ernst ;
Hagenauer, Junia ;
Alkadhi, Hatem ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2022, 57 (06) :399-405
[2]   Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner [J].
Andreini, Daniele ;
Pontone, Gianluca ;
Mushtaq, Saima ;
Conte, Edoardo ;
Guglielmo, Marco ;
Mancini, Maria Elisabetta ;
Annoni, Andrea ;
Baggiano, Andrea ;
Formenti, Alberto ;
Montorsi, Piero ;
Magatelli, Marco ;
Di Odoardo, Luca ;
Melotti, Eleonora ;
Resta, Marta ;
Muscogiuri, Giuseppe ;
Fiorentini, Cesare ;
Bartorelli, Antonio L. ;
Pepi, Mauro .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 274 :382-387
[3]   Multidetector Computed Tomography Coronary Angiography for the Assessment of Coronary In-Stent Restenosis [J].
Andreini, Daniele ;
Pontone, Gianluca ;
Mushtaq, Saima ;
Pepi, Mauro ;
Bartorelli, Antonio Luca .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (05) :645-655
[4]   CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree [J].
Annoni, Andrea D. ;
Andreini, Daniele ;
Pontone, Gianluca ;
Mancini, Maria Elisabetta ;
Formenti, Alberto ;
Mushtaq, Saima ;
Baggiano, Andrea ;
Conte, Edoardo ;
Guglielmo, Marco ;
Muscogiuri, Giuseppe ;
Muratori, Manuela ;
Fusini, Laura ;
Trabattoni, Daniela ;
Teruzzi, Giovanni ;
Santos, Ana I. Coutinho ;
Agrifoglio, Marco ;
Pepi, Mauro .
BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1090)
[5]   Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) / transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography [J].
Blanke, Philipp ;
Weir-McCall, Jonathan R. ;
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Jilaihawi, Hasan ;
Marwan, Mohamed ;
Norgaard, Bjarne L. ;
Piazza, Niccolo ;
Schoenhagen, Paul ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) :1-20
[6]   First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography [J].
Boccalini, Sara ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Diaw, Adja ;
Varasteh, Mohammad ;
Rodesch, Pierre-Antoine ;
Villien, Marjorie ;
Sigovan, Monica ;
Dessouky, Riham ;
Coulon, Philippe ;
Yagil, Yoad ;
Lahoud, Elias ;
Erhard, Klaus ;
Rioufol, Gilles ;
Finet, Gerard ;
Bonnefoy-Cudraz, Eric ;
Bergerot, Cyrille ;
Boussel, Loic ;
Douek, Philippe C. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (04) :212-221
[7]   Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation [J].
Boccalini S. ;
den Harder A.M. ;
Witsenburg M. ;
Breur J.P.J.M. ;
Krestin G.P. ;
van Beynum I.M. ;
Attrach M. ;
Stagnaro N. ;
Marasini M. ;
de Jong P.A. ;
Leiner T. ;
Budde R.P.J. .
European Radiology Experimental, 2 (1)
[8]   Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe: executive summary [J].
Byrne, Robert A. ;
Serruys, Patrick W. ;
Baumbach, Andreas ;
Escaned, Javier ;
Fajadet, Jean ;
James, Stefan ;
Joner, Michael ;
Oktay, Semih ;
Jueni, Peter ;
Kastrati, Adnan ;
Sianos, George ;
Stefanini, Giulio G. ;
Wijns, William ;
Windecker, Stephan .
EUROPEAN HEART JOURNAL, 2015, 36 (38) :2608-2620
[9]   Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Boogers, Mark J. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Reiber, Johannes H. C. ;
Sieders, Allard ;
Spano, Fabrizio ;
Jukema, J. Wouter ;
Schalij, Martin J. ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :331-340
[10]   Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility [J].
Decker, Josua A. A. ;
O'Doherty, Jim ;
Schoepf, U. Joseph ;
Todoran, Thomas M. M. ;
Aquino, Gilberto J. J. ;
Brandt, Verena ;
Baruah, Dhiraj ;
Fink, Nicola ;
Zsarnoczay, Emese ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Allmendinger, Thomas ;
Risch, Franka ;
Varga-Szemes, Akos ;
Emrich, Tilman .