Tetraethylenepentamine-derived carbon dots and tetraethylenepentamine co-immobilized silica stationary phase for hydrophilic interaction chromatography

被引:9
作者
Cai, Tianpei [1 ,2 ,3 ]
Sun, Xiaoyu [3 ]
Chen, Jia [1 ,2 ]
Qiu, Hongdeng [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, CAS Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
[3] Yancheng Inst Technol, Sch Chem & Chem Engn, Yancheng 224000, Jiangsu, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Tetraethylenepentamine; Carbon dots; Hydrophilic liquid chromatography; Stationary phase; Synergistic effect; RETENTION; NANOMATERIALS; ADSORPTION; NANOTUBES; BEHAVIOR; ACID;
D O I
10.1016/j.chroma.2023.464325
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, tetraethylenepentamine (TEPA) was used as precursor and reaction medium to prepare tetraethylenepentamine-functionalized carbon dots (TEPACDs), the resultant mixture was subsequently silanized and then grafted on the surface of bare silica. The obtained tetraethylenepentamine-functionalized carbon dots and tetraethylenepentamine co-modified silica stationary phase (Sil-TEPA/CDs) was characterized by multiple ways, such as Fourier transformed infrared spectroscopy (FTIR), elemental analysis and transmission electron microscope, which revealed the successful preparation of the mixed stationary phase and higher density of functional groups on co-modified stationary phase than precursor single-modified stationary phase. The synergistic effect of TEPACDs and TEPA was proved by comparing the separation performance of Sil-TEPA/CDs and Sil-TEPA toward amino acids, nucleosides, and nucleobases, which distinctly enhanced the selectivity of SilTEPA/CDs. Thus, 12 nucleosides and nucleobases and 11 amino acids was nicely separated on Sil-TEPA/CDs. By study the influences of the changes of mobile phase composition, mobile phase buffer concentration and buffer pH on the retention behaviors of Sil-TEPA and Sil-TEPA/CDs, it was found that both hydrophilic partitioning and adsorption of analytes on Sil-TEPA/CDs were enhanced benefit from the co-existence of TEPA and TEPACDs, which provided the analytes better separation performance. By comparing the column quality of SilTEPA/CDs with four commercially available columns, Sil-TEPA/CDs exhibited the best peak asymmetry of 0.98, and second best column efficiency of 43895 m-1 using guanosine as analyte. The RSD (n = 9) of the retention times of five selected analytes on Sil-TEPA/CDs were within 0.30-0.61% during 40 h of continuously elution, which implied excellent stability of prepared packing material.
引用
收藏
页数:9
相关论文
共 39 条
[1]   Application of carbon nanotubes in extraction and chromatographic analysis: A review [J].
ALOthman, Zeid Abdullah ;
Wabaidur, Saikh Mohammad .
ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (05) :633-651
[2]   Electrostatic repulsion hydrophilic interaction chromatography for isocratic separation of charged solutes and selective isolation of phosphopeptides [J].
Alpert, Andrew J. .
ANALYTICAL CHEMISTRY, 2008, 80 (01) :62-76
[3]   Effect of salts on retention in hydrophilic interaction chromatography [J].
Alpert, Andrew J. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1538 :45-53
[4]   Polyethyleneimine-functionalized carbon dots and their precursor co-immobilized on silica for hydrophilic interaction chromatography [J].
Cai, Tianpei ;
Zhang, Haijuan ;
Chen, Jia ;
Li, Zhan ;
Qiu, Hongdeng .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1597 :142-148
[5]   Octadecylamine and glucose-coderived hydrophobic carbon dots-modified porous silica for chromatographic separation [J].
Chen, Jia ;
Yuan, Ning ;
Jiang, Danni ;
Lei, Qian ;
Liu, Bei ;
Tang, Weiyang ;
Row, Kyung Ho ;
Qiu, Hongdeng .
CHINESE CHEMICAL LETTERS, 2021, 32 (11) :3398-3401
[6]   Carbon dots in sample preparation and chromatographic separation: Recent advances and future prospects [J].
Chen, Jia ;
Gong, Zhengjun ;
Tang, Weiyang ;
Row, Kyung Ho ;
Qiu, Hongdeng .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 134
[7]   Mesoporous nanomaterial-assisted hydrogel double network composite for mixed-mode liquid chromatography [J].
Fan, Fangbin ;
Lu, Xiaofeng ;
Wang, Shuai ;
Wang, Licheng ;
Liang, Xiaojing ;
Guo, Yong .
MICROCHIMICA ACTA, 2021, 188 (12)
[8]   Phosphorus-doped deep eutectic solvent-derived carbon dots-modified silica as a mixed-mode stationary phase for reversed-phase and hydrophilic interaction chromatography [J].
Fu, Gafang ;
Gao, Chenxi ;
Quan, Kaijun ;
Li, Hui ;
Qiu, Hongdeng ;
Chen, Jia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (18) :4255-4264
[9]   Deep eutectic solvents-derivated carbon dots-decorated silica stationary phase with enhanced separation selectivity in reversed-phase liquid chromatography [J].
Fu, Gafang ;
Chen, Jia ;
Qiu, Hongdeng .
JOURNAL OF CHROMATOGRAPHY A, 2022, 1681
[10]   Synthesis of carbon dots-based covalent organic nanomaterial as stationary phase for open tubular capillary electrochromatography [J].
Fu, Yuanyuan ;
Li, Zhentao ;
Hu, Changjun ;
Li, Qiaoyan ;
Chen, Zilin .
JOURNAL OF CHROMATOGRAPHY A, 2022, 1678