Finite element analysis of concrete-encased columns reinforced with multiple steel sections

被引:0
作者
Bao, Lianjin [1 ,2 ]
Li, Guoqiang [1 ]
Fan, Feng [3 ]
Zhao, Hang [4 ]
Huang, Gang [4 ]
Sun, Jianyun [4 ]
Sun, Feifei [1 ]
机构
[1] Tongji Univ, Sch Civil Engn, Shanghai, Peoples R China
[2] East China Architectural Design & Res Inst Co Ltd, Shanghai, Peoples R China
[3] Harbin Inst Technol, Harbin, Peoples R China
[4] China Construct Ind Engn & Technol Res Acad Co Ltd, 15 Linhe Ave, Beijing 101300, Peoples R China
关键词
concrete-encased columns; fiber element analysis; finite element analysis; multiple steel sections; strain compatibility; COMPOSITE COLUMNS; BEHAVIOR; STRENGTH; BEAM; ACI;
D O I
10.1002/tal.2110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-encased columns reinforced with one built-up steel core are widely used as mega columns in high-rise buildings. Due to the enormous size of the steel core, multiple steel segments have to be welded and spliced on-site, which might inflict detrimental impacts on the integrity and ductility of the columns. To solve this practical issue, one method using multiple steel sections to replace one gigantic built-up section is proposed. However, whether those columns reinforced with individual steel sections could have the same capacity as the ones reinforced with one steel core and whether the current design method relying on strain compatibility is still applicable to design such columns remain unknown. In this study, one column specimen reinforced with multiple steel sections is tested and the test results are utilized to calibrate finite element models. Afterward, finite element (FE) analysis is performed on concrete-encased columns reinforced with multiple steel sections to numerically examine the load capacity of those columns. Based on the numerical analysis, a design method based on modified strain distribution is proposed. Numerical results indicate that concrete-encased columns reinforced with multiple steel sections exhibit similar performance compared with the one reinforced with one steel core, showing great potential to be applied as mega columns in high-rise buildings.
引用
收藏
页数:20
相关论文
共 31 条
  • [21] A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading
    Rodrigues, Hugo
    Varum, Humberto
    Arede, Antonio
    Costa, Anibal
    [J]. ENGINEERING STRUCTURES, 2012, 35 : 149 - 164
  • [22] Sliman K. Z., 2013, HBRC J, V9, P134
  • [23] Systemes Dassault., 2020, ABAQUS ANAL USERS GU
  • [24] Varum H., 2003, THESIS U AVEIRO
  • [25] Post-fire seismic performance of SRC beam to SRC column frames
    Wang, Guang-Yong
    Zhang, Chao
    Xu, Jie
    Zhang, Dong-Ming
    [J]. STRUCTURES, 2020, 25 : 323 - 334
  • [26] Experimental Investigation of the Seismic Behavior of Low-Yield-Point Corrugated Steel Plate Dampers
    Wang, Wei
    Song, Jiangliang
    Wang, Wanzhi
    Dingo, Xiaobo
    Lu, Zheng
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (02)
  • [27] Comparisons of concrete-encased composite column strength provisions of ACI code and AISC specification
    Weng, CC
    Yen, SI
    [J]. ENGINEERING STRUCTURES, 2002, 24 (01) : 59 - 72
  • [28] Shear strength of concrete-encased composite structural members
    Weng, CC
    Yen, SI
    Chen, CC
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (10): : 1190 - 1197
  • [29] Equivalent viscous damping for steel concentrically braced frame structures
    Wijesundara, K. K.
    Nascimbene, R.
    Sullivan, T. J.
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2011, 9 (05) : 1535 - 1558
  • [30] Xue J., 2014, ENG MECH, V31, P2