Diagnosis of Interturn Short-Circuit of SRM Based on Ratio of Current Components

被引:10
作者
Chen, Hao [1 ,2 ,3 ,4 ]
Fang, Chenghui [1 ,2 ,3 ,4 ]
Dong, Jinlong [5 ]
Lu, Shengli [6 ]
Pires, Vitor [7 ,8 ]
Martins, Joao [9 ]
Aguirre, Miguel Pablo [10 ]
机构
[1] China Univ Min & Technol, Sch Elect Engn, Xuzhou 221116, Peoples R China
[2] Int Joint Res Ctr Cent & Eastern European Countrie, Xuzhou 221008, Peoples R China
[3] Int Cooperat Joint Lab New Energy Power Generat &, Xuzhou 221008, Peoples R China
[4] Xuzhou Key Lab New Energy Elect Vehicle Technol &, Xuzhou 221008, Peoples R China
[5] State Grid Laiwu Power Supply Serv Command Ctr, Jinan 250102, Peoples R China
[6] Nanjing Res Inst Elect Technol, Nanjing 210012, Peoples R China
[7] Polytech Inst Setubal, Setubal Sch Technol, P-2914508 Setubal, Portugal
[8] INESC ID, P-1049001 Lisbon, Portugal
[9] CTS UNINOVA, FCT UNL, Dept Elect Engn, P-2829517 Caparica, Portugal
[10] Inst Tecnol Buenos Aires, C1106ACD, Buenos Aires, Argentina
基金
中国国家自然科学基金;
关键词
Fault diagnosis; interturn short-circuit; switched reluctance motor (SRM); symmetrical component; FAULT-DIAGNOSIS;
D O I
10.1109/TTE.2022.3224596
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interturn short-circuit is a common fault mode of switched reluctance motors (SRMs) that cause changes in the parameters of the motor that can cause vibrations and noise. In this article, a diagnosis method is proposed to detect short-circuit fault. First, the model of a phase winding with interturn short-circuit is built and the fault characteristics are analyzed. Under normal condition, the sinusoidal components of phase currents are mostly a positive sequence with minimum distortion. The frequency signature of the motor is extracted by Fourier analysis when operating in normal conditions. When a fault condition occurs, the symmetry of the phase currents is broken, and both negative and zero sequence components of the phase currents appear. According to the asymmetry, an index, the ratio of negative to positive sequence components of the phase currents, is defined to identify whether the motor is working normally. The proposal is verified by simulations and experiments on a three-phase 12/8 structure SRM under different mechanical operating conditions. In normal condition, the fault index is about 0.02; in 12.5% fault condition, the fault index rises to about 0.07; in 25% fault condition, the fault index rises to about 0.08. According to the experimental results, fault index is robust because it is not influenced by the following parameters: turn on angle, turn off angle, rotor speed, load torque, and so on.
引用
收藏
页码:3319 / 3327
页数:9
相关论文
共 25 条
[1]   Linearized Modeling of Switched Reluctance Motor for Closed-Loop Current Control [J].
Ahmad, Syed Shahjahan ;
Narayanan, G. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (04) :3146-3158
[2]   A Novel Control-Independent Online Fault Diagnosis of Interturn Short Circuits in SRMs Using Signal Injection Technique [J].
Alam, Mahetab ;
Payami, Saifullah .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (03) :2157-2167
[3]   Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators [J].
Aubert, Brice ;
Regnier, Jeremi ;
Caux, Stephane ;
Alejo, Dominique .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) :1921-1930
[4]   Thermal Signature Analysis of an 8/6 Switched Reluctance Motor under Inter-Turn Short Circuit Fault [J].
Caicedo-Narvaez, Carlos ;
Li, Yinan ;
Maharjan, Lizon ;
Cosoroaba, Eva ;
Fahimi, Babak ;
Kiani, Morgan ;
Moallem, Mehdi .
2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, :1859-1864
[5]  
Chen H., 2016, IEEE T APPL SUPERCON, V26, P1
[6]   Fault Diagnosis Digital Method for Power Transistors in Power Converters of Switched Reluctance Motors [J].
Chen, Hao ;
Lu, Shengli .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (02) :749-763
[7]  
Dong J., 2016, THESIS CHINA U MININ
[8]   Stator Winding Interturn Short-Circuit Faults Severity Detection Controlled by OW-SVPWM Without CMV of a Five-Phase FTFSCW-IPM [J].
Fan, Ying ;
Li, Chenxue ;
Zhu, Weixia ;
Zhang, Xiangyang ;
Zhang, Li ;
Cheng, Ming .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (01) :194-202
[9]   Classification and remediation of electrical faults in the switched reluctance drive [J].
Gopalakrishnan, S ;
Omekanda, AM ;
Lequesne, B .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (02) :479-486
[10]   Online Interturn Fault Diagnosis of Permanent Magnet Synchronous Machine Using Zero-Sequence Components [J].
Hang, Jun ;
Zhang, Jianzhong ;
Cheng, Ming ;
Huang, Jin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (12) :6731-6741