Stability of Ti3C2T x MXene Films and Devices under Clinical Sterilization Processes

被引:6
作者
Averbeck, Spencer R. R. [1 ,2 ]
Xu, Doris [1 ,2 ]
Murphy, Brendan B. B. [1 ,2 ]
Shevchuk, Kateryna [3 ,4 ]
Shankar, Sneha [1 ,2 ]
Anayee, Mark [3 ,4 ]
Der Torossian Torres, Marcelo [1 ,5 ,6 ,7 ,8 ]
Beauchamp, Michael S. S. [9 ]
de la Fuente-Nunez, Cesar [6 ,7 ]
Gogotsi, Yury [3 ,4 ]
Vitale, Flavia [1 ,2 ,10 ,11 ,12 ]
机构
[1] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[2] Univ Penn, Ctr Neuroengn & Therapeut, Philadelphia, PA 19104 USA
[3] Drexel Univ, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
[4] Drexel Univ, AJ Drexel Nanomat Inst, Philadelphia, PA 19104 USA
[5] Univ Penn, Dept Chem & Biomol Engn, Philadelphia, PA 19104 USA
[6] Univ Penn, Perelman Sch Med, Dept Psychiat, Philadelphia, PA 19104 USA
[7] Univ Penn, Perelman Sch Med, Dept Microbiol, Philadelphia, PA 19104 USA
[8] Univ Penn, Inst Biomed Informat, Philadelphia, PA 19104 USA
[9] Univ Penn, Dept Neurosurg, Philadelphia, PA 19104 USA
[10] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[11] Univ Penn, Dept Phys Med & Rehabil, Philadelphia, PA 19104 USA
[12] Corporal Michael J Crescenz Vet Affairs Med Ctr, Ctr Neurotrauma Neurodegenerat & Restorat, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MXenes; bioelectronics; Ti3C2T x; sterilization; wearables; implantable electrodes; 2-DIMENSIONAL TI3C2; ELECTRODES; OXIDATION; STIMULATION; GUIDELINES; TUTORIAL;
D O I
10.1021/acsnano.3c01525
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
MXenes are being heavily investigatedin biomedical research,withapplications ranging from regenerative medicine to bioelectronics.To enable the adoption and integration of MXenes into therapeuticplatforms and devices, however, their stability under standard sterilizationprocedures must be established. Here, we present a comprehensive investigationof the electrical, chemical, structural, and mechanical effects ofcommon thermal (autoclave) and chemical (ethylene oxide (EtO) andH(2)O(2) gas plasma) sterilization protocols onboth thin-film Ti3C2T x MXene microelectrodes and mesoscale arrays made from Ti3C2T x -infused cellulose-elastomercomposites. We also evaluate the effectiveness of the sterilizationprocesses in eliminating all pathogens from the Ti3C2T x films and composites. Post-sterilizationanalysis revealed that autoclave and EtO did not alter the DC conductivity,electrochemical impedance, surface morphology, or crystallographicstructure of Ti3C2T x and were both effective at eliminating E. coli fromboth types of Ti3C2T x -based devices. On the other end, exposure to H2O2 gas plasma sterilization for 45 min induced severe degradationof the structure and properties of Ti3C2T x films and composites. The stability of theTi(3)C(2)T( x ) after EtOand autoclave sterilization and the complete removal of pathogensestablish the viability of both sterilization processes for Ti3C2T x -based technologies.
引用
收藏
页码:9442 / 9454
页数:13
相关论文
共 57 条
[1]  
Adar F., 2010, Microscopy and Microanalysis, V16, P360
[2]   H2O2 assisted room temperature oxidation of Ti2C MXene for Li-ion battery anodes [J].
Ahmed, Bilal ;
Anjum, Dalaver H. ;
Hedhili, Mohamed N. ;
Gogotsi, Yury ;
Alshareef, Husam N. .
NANOSCALE, 2016, 8 (14) :7580-7587
[3]   Guidelines for Synthesis and Processing of Two-Dimensional Titanium Carbide (Ti3C2TX MXene) [J].
Alhabeb, Mohamed ;
Maleski, Kathleen ;
Anasori, Babak ;
Lelyukh, Pavel ;
Clark, Leah ;
Sin, Saleesha ;
Gogotsi, Yury .
CHEMISTRY OF MATERIALS, 2017, 29 (18) :7633-7644
[4]  
[Anonymous], 2008, Guideline for Disinfection and Sterilization in Healthcare Facilities
[5]   Presurgical language localization with visual naming associated ECoG high- gamma modulation in pediatric drug-resistant epilepsy [J].
Arya, Ravindra ;
Wilson, J. Adam ;
Fujiwara, Hisako ;
Rozhkov, Leonid ;
Leach, James L. ;
Byars, Anna W. ;
Greiner, Hansel M. ;
Vannest, Jennifer ;
Buroker, Jason ;
Milsap, Griffin ;
Ervin, Brian ;
Minai, Ali ;
Horn, Paul S. ;
Holland, Katherine D. ;
Mangano, Francesco T. ;
Crone, Nathan E. ;
Rose, Douglas F. .
EPILEPSIA, 2017, 58 (04) :663-673
[6]   Resolving surface chemical states in XPS analysis of first row transition metals, oxides and hydroxides: Cr, Mn, Fe, Co and Ni [J].
Biesinger, Mark C. ;
Payne, Brad P. ;
Grosvenor, Andrew P. ;
Lau, Leo W. M. ;
Gerson, Andrea R. ;
Smart, Roger St. C. .
APPLIED SURFACE SCIENCE, 2011, 257 (07) :2717-2730
[7]   Tutorial: guidelines for standardized performance tests for electrodes intended for neural interfaces and bioelectronics [J].
Boehler, Christian ;
Carli, Stefano ;
Fadiga, Luciano ;
Stieglitz, Thomas ;
Asplund, Maria .
NATURE PROTOCOLS, 2020, 15 (11) :3557-3578
[8]   An investigation into the factors governing the oxidation of two-dimensional Ti3C2 MXene [J].
Chae, Yoonjeong ;
Kim, Seon Joon ;
Cho, Soo-Yeon ;
Choi, Junghoon ;
Maleski, Kathleen ;
Lee, Byeong-Joo ;
Jung, Hee-Tae ;
Gogotsi, Yury ;
Lee, Yonghee ;
Ahn, Chi Won .
NANOSCALE, 2019, 11 (17) :8387-8393
[9]   Development of a neural interface for high-definition, long-term recording in rodents and nonhuman primates [J].
Chiang, Chia-Han ;
Won, Sang Min ;
Orsborn, Amy L. ;
Yu, Ki Jun ;
Trumpis, Michael ;
Bent, Brinnae ;
Wang, Charles ;
Xue, Yeguang ;
Min, Seunghwan ;
Woods, Virginia ;
Yu, Chunxiu ;
Kim, Bong Hoon ;
Kim, Sung Bong ;
Huq, Rizwan ;
Li, Jinghua ;
Seo, Kyung Jin ;
Vitale, Flavia ;
Richardson, Andrew ;
Fang, Hui ;
Huang, Yonggang ;
Shepard, Kenneth ;
Pesaran, Bijan ;
Rogers, John A. ;
Viventi, Jonathan .
SCIENCE TRANSLATIONAL MEDICINE, 2020, 12 (538)
[10]   Biocompatible 2D Titanium Carbide (MXenes) Composite Nanosheets for pH-Responsive MRI-Guided Tumor Hyperthermia [J].
Dai, Chen ;
Lin, Han ;
Xu, Guang ;
Liu, Zhuang ;
Wu, Rong ;
Chen, Yu .
CHEMISTRY OF MATERIALS, 2017, 29 (20) :8637-8652