Computational Fluid Dynamics Analysis of an Open-Pool Nuclear Research Reactor Core for Fluid Flow Optimization Using a Channel Box

被引:0
作者
Scuro, N. L. [1 ,2 ]
Angelo, G. [3 ]
Angelo, E. [3 ]
Piro, M. H. A. [2 ]
Umbehaun, P. E. [1 ]
Torres, W. M. [1 ]
Andrade, D. A. [1 ]
机构
[1] Nucl & Energy Res Inst, Nucl Engn Ctr, Sao Paulo, Brazil
[2] Ontario Tech Univ, Dept Energy & Nucl Engn, Oshawa, ON, Canada
[3] Univ Prebiteriana Mackenzie, Sch Engn, Sao Paulo, Brazil
基金
加拿大自然科学与工程研究理事会;
关键词
Research reactor core; flow distribution optimization; computational fluid dynamics; channel box; MTR RESEARCH REACTOR; COMPREHENSIVE APPROACH; CFD SIMULATIONS; VERIFICATION; VALIDATION; INVERSION; BENCHMARK; INLET; CODE;
D O I
10.1080/00295639.2022.2142437
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A channel box installation in the IEA-R1 research reactor core was numerically investigated to increase fluid flow in fuel assemblies (FAs) and side water channels (SWCs) between FAs by minimizing bypasses in specific regions of the reactor core, which is expected to reduce temperatures and oxidation effects in lateral fuel plates (LFPs). To achieve this objective, an isothermal three-dimensional computational fluid dynamics model was created using Ansys CFX to analyze fluid flow distribution in the Brazilian IEA-R1 research reactor core. All regions of the core and realistic boundary conditions were considered, and a detailed mesh convergence study is presented. Results comparing both scenarios are presented in the percentage of use of the primary circuit pump. It is indicated that 21.4% of fluid bypass to unnecessary regions can be avoided with the channel box installation, which leads to the total mass flow from the primary circuit for all FAs increasing from 68.9% (without a channel box) to 77.6% (with a channel box). For the SWCs, responsible for cooling LFPs, an increment from 9.7% to 22.4%, avoiding all nondesired cross three-dimensional effects, was observed, resulting in a more homogeneous fluid flow and vertical velocities. It was concluded that the installation of a channel box numerically indicates an expressive mass flow increase and homogeneous fluid flow distribution for flow dynamics in relevant regions. This gives greater confidence to believe that lower temperatures, and consequently oxidation effects in LFPs, can be expected with a channel box installation.
引用
收藏
页码:1100 / 1116
页数:17
相关论文
共 38 条
[1]  
[Anonymous], RES REACT DAT RRDB W
[2]  
[Anonymous], 2003, TECDOC SERIES, V418
[3]  
[Anonymous], 2009, TECDOC SERIES, V1625
[4]  
[Anonymous], 2010, TECDOC SERIES, V1637
[5]  
[Anonymous], 2013, ANS CFX PREUS GUID, V13
[6]  
[Anonymous], 2015, TECHNICAL REPORTS SE, V480
[7]   CFD analysis of flow distribution at the core inlet of SMART [J].
Bae, Youngmin ;
Kim, Young In ;
Park, Cheon Tae .
NUCLEAR ENGINEERING AND DESIGN, 2013, 258 :19-25
[8]   Study of core flow distribution for small modular natural circulation lead or lead-alloy cooled fast reactors [J].
Chen, Zhao ;
Zhao, Pengcheng ;
Zhou, Guangming ;
Chen, Hongli .
ANNALS OF NUCLEAR ENERGY, 2014, 72 :76-83
[9]   Procedures for manufacturing an instrumented nuclear fuel element [J].
Durazzo, M. ;
Umbehaun, P. E. ;
Torres, W. M. ;
Souza, J. A. B. ;
Silva, D. G. ;
Andrade, D. A. .
PROGRESS IN NUCLEAR ENERGY, 2019, 113 :166-174
[10]   Prediction, analysis and solution of flow inversion phenomenon in a typical MTR reactor with upward core cooling [J].
El-Morshedy, S. El-Din .
KERNTECHNIK, 2010, 75 (06) :342-351