3D-printed titanium surgical guides for extraction of horizontally impacted lower third molars

被引:11
作者
Qi, Wei [1 ,2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Qian, Jing [2 ,3 ,4 ,5 ,6 ,7 ,8 ,9 ]
Zhou, Wei [1 ,2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Li, Jiannan [1 ,2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Mao, Bochun [2 ,3 ,4 ,5 ,6 ,7 ,8 ,10 ]
Wen, Aonan [2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Zhao, Yijiao [2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Pan, Jie [1 ,2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Wang, Yong [2 ,3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Gen Dent, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[2] Natl Ctr Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[5] Beijing Key Lab Digital Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[6] Res Ctr Engn & Technol Computerized Dent, Minist Hlth, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[7] NMPA Key Lab Dent Mat, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[8] Peking Univ, Sch & Hosp Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[9] Peking Univ, Sch & Hosp Stomatol, Div 5, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[10] Peking Univ, Sch & Hosp Stomatol, Dept Orthodont, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
关键词
Guided surgery; Impacted lower third molar; Horizontal; Postoperative complication; IMPLANT PLACEMENT; ACCURACY; SURGERY; REMOVAL; TEETH; TOOTH;
D O I
10.1007/s00784-022-04769-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This prospective study introduced a digitally designed sectioning guide and evaluated its feasibility for the extraction of horizontally impacted lower third molars. Materials and methods This study included 38 horizontally impacted lower third molars, randomly divided into experimental and control groups. The teeth were extracted using a 3D-printed titanium surgical guide in the experimental group; free-hand extractions were performed in the control group. The surgical duration, tooth sectioning duration, cortical bone perforation, and postoperative complications, including pain, swelling, trismus, dry socket, infection, and hemorrhage, were evaluated. Results Although not statistically significant, guided surgery tended to reduce the number of tooth sectioning steps compared to free-hand extractions. There were no cases of cortical bone perforation in the experimental group. Although the surgical duration was greater in the experimental group (p < 0.05), there were no differences in postoperative pain, swelling, and trismus. There were no cases of postoperative infection and hemorrhage in either group. Conclusions 3D-printed titanium surgical guides had superior accuracy and safety compared to free-hand surgery. Further studies with larger sample sizes are required to verify these findings.
引用
收藏
页码:1499 / 1507
页数:9
相关论文
共 31 条
[1]  
Ahmed Mamdouhh, 2018, Open Access Maced J Med Sci, V6, P2395, DOI [10.3889/oamjms.2018.371, 10.3889/oamjms.2018.371]
[2]   Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study [J].
Arisan, Volkan ;
Karabuda, Z. Cuneyt ;
Ozdemir, Tayfun .
JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) :43-51
[3]   Effects of varied dimensions of surgical guides on implant angulations [J].
Choi, M ;
Romberg, E ;
Driscoll, CF .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (05) :463-469
[4]   Piezoelectric bone surgery for impacted lower third molar extraction compared with conventional rotary instruments a systematic review, meta- analysis, and trial sequential analysis [J].
Cicciu, M. ;
Stacchi, C. ;
Fiorillo, L. ;
Cervino, G. ;
Troiano, G. ;
Vercellotti, T. ;
Herford, A. S. ;
Galindo-Moreno, P. ;
Di Lenarda, R. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (01) :121-131
[5]   Microguided Endodontics: Accuracy of a Miniaturized Technique for Apically Extended Access Cavity Preparation in Anterior Teeth [J].
Connert, Thomas ;
Zehnder, Marc S. ;
Weiger, Roland ;
Kuhl, Sebastian ;
Krastl, Gabriel .
JOURNAL OF ENDODONTICS, 2017, 43 (05) :787-790
[6]   Alveolar repair after the use of piezosurgery in the removal of lower third molars: a prospective clinical, randomised, double-blind, split-mouth study [J].
de Freitas Silva, L. ;
Ribeiro de Carvalho Reis, E. N. ;
Oliveira Souza, B. C. ;
Egas, L. S. ;
Aranega, A. M. ;
Ponzoni, D. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2019, 57 (10) :1068-1073
[7]   Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery [J].
El Kholy, Karim ;
Lazarin, Rafael ;
Janner, Simone F. M. ;
Faerber, Karin ;
Buser, Ramona ;
Buser, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) :1067-1075
[8]   A stereolithographic template for computer-assisted teeth preparation in dental esthetic ceramic veneer treatment [J].
Gao, Jing ;
Li, Junying ;
Liu, Chunxu ;
Fan, Lin ;
Yu, Jiayi ;
Yu, Haiyang .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (08) :763-769
[9]   Comparison of postoperative morbidity between piezoelectric surgery and conventional rotary instruments in mandibular third molar surgery: a split-mouth clinical study [J].
Gulnahar, Yakup ;
Alpan, Aysan Lektemur .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (03) :E269-E275
[10]   Influence of tooth sectioning technique and various risk factors in reducing the IAN injury following surgical removal of an impacted mandibular third molar [J].
Jain N. ;
Thomas S. ;
Prabhu S. ;
Jain S. ;
Pathak A.D. ;
Pillai A. ;
Satpathy M. .
Oral and Maxillofacial Surgery, 2016, 20 (2) :149-156