Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis

被引:16
作者
Diaconu, Alexandru [1 ]
Holte, Michael Boelstoft [1 ,2 ]
Berg-Beckhoff, Gabriele [3 ]
Pinholt, Else Marie [1 ,2 ]
机构
[1] Univ Hosp Southern Denmark, Dept Oral & Maxillofacial Surg, 3D Lab Denmark, Finsensgade 35, DK-6700 Esbjerg, Denmark
[2] Univ Southern Denmark, Fac Hlth Sci, Dept Reg Hlth Res, Finsensgade 35, DK-6700 Esbjerg, Denmark
[3] Univ Southern Denmark, Fac Hlth Sci, Dept Publ Hlth, Degnevej 14, DK-6705 Esbjerg, Denmark
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 01期
关键词
patient-specific implants; orthognathic surgery; accuracy; stability; three-dimensional; systematic review; meta-analysis; CUSTOMIZED SURGICAL GUIDES; PATIENT-SPECIFIC IMPLANTS; TITANIUM PLATES; CUTTING GUIDES; SUPERIMPOSITION; OSTEOSYNTHESIS; FIXATION; REGISTRATION; VALIDATION; PROTOCOL;
D O I
10.3390/jpm13010125
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65 degrees in pitch. PSIs were up to 0.85 mm and 2.35 degrees more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.
引用
收藏
页数:24
相关论文
共 56 条
  • [1] What is the Accuracy of Bimaxillary Orthognathic Surgery Using Occlusally-Based Guides and Patient-Specific Fixation In Both Jaws? A Cohort Study and Discussion of Surgical Techniques (vol 80, pg 1912, 2022)
    Abel, Adam R.
    Ho, Kaylee
    Neugarten, Jay M.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 81 (03) : 379 - 379
  • [2] Accuracy of virtual planning in orthognathic surgery: a systematic review
    Alkhayer, Ali
    Piffko, Jozsef
    Lippold, Carsten
    Segatto, Emil
    [J]. HEAD & FACE MEDICINE, 2020, 16 (01)
  • [3] Comparison of the Accuracy of Voxel Based Registration and Surface Based Registration for 3D Assessment of Surgical Change following Orthognathic Surgery
    Almukhtar, Anas
    Ju, Xiangyang
    Khambay, Balvinder
    McDonald, James
    Ayoub, Ashraf
    [J]. PLOS ONE, 2014, 9 (04):
  • [4] Feasibility of iterative closest point algorithm for accuracy between virtual surgical planning and orthognathic surgery outcomes
    Alves Marliere, Daniel Amaral
    Demetrio, Mauricio Silva
    Verner, Francielle Silvestre
    Asprino, Luciana
    de Miranda Chaves Netto, Henrique Duque
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (07) : 1031 - 1040
  • [5] Computed tomography imaging superimposition protocols to assess outcomes in orthognathic surgery: a systematic review with comprehensive recommendations
    Andriola, Fernando de Oliveira
    Haas Junior, Orion Luiz
    Guijarro-Martinez, Raquel
    Hernandez-Alfaro, Federico
    de Oliveira, Rogerio Belle
    Pagnoncelli, Rogerio Miranda
    Swennen, Gwen R. J.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (03)
  • [6] The current state of computer assisted orthognathic surgery: A narrative review
    Apostolakis, Dimitrios
    Michelinakis, George
    Kamposiora, Phophi
    Papavasiliou, George
    [J]. JOURNAL OF DENTISTRY, 2022, 119
  • [7] Validation of the OrthoGnathicAnalyser 2.0-3D accuracy assessment tool for bimaxillary surgery and genioplasty
    Baan, Frank
    Sabelis, Juliana F.
    Schreurs, Ruud
    van de Steeg, Gert
    Xi, Tong
    van Riet, Tom C. T.
    Becking, Alfred G.
    Maal, Thomas J. J.
    [J]. PLOS ONE, 2021, 16 (01):
  • [8] PSI-Guided Mandible-First Orthognathic Surgery: Maxillo-Mandibular Position Accuracy and Vertical Dimension Adjustability
    Badiali, Giovanni
    Bevini, Mirko
    Lunari, Ottavia
    Lovero, Elisa
    Ruggiero, Federica
    Bolognesi, Federico
    Feraboli, Liliana
    Bianchi, Alberto
    Marchetti, Claudio
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (11):
  • [9] Validation of a patient-specific system for mandible-first bimaxillary surgery: ramus and implant positioning precision assessment and guide design comparison
    Badiali, Giovanni
    Bevini, Mirko
    Ruggiero, Federica
    Cercenelli, Laura
    Lovero, Elisa
    De Simone, Elisabetta
    Rucci, Paola
    Bianchi, Alberto
    Marchetti, Claudio
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256