Indoor environmental quality in offices and risk of health and productivity complaints at work: A literature review

被引:26
作者
Felgueiras, Fatima [1 ,2 ,3 ]
Mourao, Zenaida [4 ]
Moreira, Andre [2 ,3 ,5 ,6 ,7 ]
Gabriel, Marta Fonseca [1 ]
机构
[1] Inst Sci & Innovat Mech & Ind Engn LAETA INEGI, Associated Lab Energy & Aeronaut, Rua Dr Roberto Frias 400, P-4200465 Porto, Portugal
[2] Univ Porto, Inst Publ Hlth, EPIUnit, Rua Taipas 135, P-4050600 Porto, Portugal
[3] Lab Integrat & Translat Res Populat Hlth ITR, Rua Taipas 135, P-4050600 Porto, Portugal
[4] Inst Syst & Comp Engn Technol & Sci INESC TEC, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[5] Univ Porto, Ctr Hosp Univ Sao Joao, Serv Imunoalergol, Al Prof Hernani Monteiro, P-4200319 Porto, Portugal
[6] Univ Porto, Fac Med, Dept Pathol, Basic & Clin Immunol Unit, Porto, Portugal
[7] Univ Porto, Fac Med, Al Prof Hernani Monteiro, P-4200319 Porto, Portugal
来源
JOURNAL OF HAZARDOUS MATERIALS ADVANCES | 2023年 / 10卷
关键词
IEQ; Offices; Health; Productivity; SEMIVOLATILE ORGANIC-COMPOUNDS; OPEN-PLAN OFFICES; AIR-QUALITY; THERMAL COMFORT; CARBON-DIOXIDE; PHTHALATE-ESTERS; BUILDINGS; EXPOSURE; PERFORMANCE; IMPACT;
D O I
10.1016/j.hazadv.2023.100314
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many service jobs are carried out in modern offices, with individual offices being increasingly replaced by open-plan settings. The high number of adult people working in office buildings, in most situations sharing the work-place with many others during a considerable part of their daily time, highlights the importance of providing adequate guidance to ensure the quality of office environments. This paper aims to summarize existing data on modern offices' indoor environmental quality (IEQ) conditions in terms of air pollution (volatile organic compounds (VOC), particulate matter and inorganic pollutants), thermal comfort, lighting and acoustics and the respective associations with health and productivity-related outcomes in workers. Evidence shows that al-though many offices present acceptable IEQ, some office settings can have levels of air pollutants, hygrothermal conditions/thermal comfort and illuminance that do not comply with the existing international standards and recommendations. In addition, findings suggest the existence of significant associations between the assessed IEQ indicators and the risk of detrimental effects on health and productivity of office workers. In particular, airborne particles, CO2, O 3 and thermal comfort were linked with the prevalence of sick building syndrome symptoms. Poor lighting and acoustical quality have also been associated with malaise and physiological stress among office workers. Similarly, better productivity levels have been registered for good indoor air quality conditions, in terms of VOC, airborne particles and CO2. Overall, the evidence revised in this work suggests that for promoting health and productivity recommendations for office building managers include actions to ensure that: i) all relevant IEQ indicators are periodically controlled to ensure that levels comply with recommended limit values; ii) declared in-door pollution sources are avoided; iii) adequate ventilation and acclimatization strategies are implemented; and iv) there is the possibility of conduct personalized adjustments to environmental conditions (following workers' preferences).
引用
收藏
页数:11
相关论文
共 109 条
  • [1] Occupant productivity and office indoor environment quality: A review of the literature
    Al Horr, Yousef
    Arif, Mohammed
    Kaushik, Amit
    Mazroei, Ahmed
    Katafygiotou, Martha
    Elsarrag, Esam
    [J]. BUILDING AND ENVIRONMENT, 2016, 105 : 369 - 389
  • [2] Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments
    Allen, Joseph G.
    MacNaughton, Piers
    Satish, Usha
    Santanam, Suresh
    Vallarino, Jose
    Spengler, John D.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) : 805 - 812
  • [3] [Anonymous], 2005, 7730 ISO
  • [4] [Anonymous], 2002, ISO 8995-1
  • [5] Artan D., 2019, P ANN INT C ARCH CIV, P145, DOI DOI 10.5176/2301-394X_ACE19.605
  • [6] Health Effects of Exposure to Indoor Semi-Volatile Organic Compounds in Chinese Building Environment: A Systematic Review
    Ataei, Yeganeh
    Sun, Yuexia
    Liu, Wei
    S. Ellie, Agnes
    Dong, Hui
    Ahmad, Umme Marium
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (01)
  • [7] Effect of lighting illuminance and colour temperature on mental workload in an office setting
    Bao, Jiayi
    Song, Xinbo
    Li, Yan
    Bai, Yinjie
    Zhou, Qianxiang
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Bartzis J.G., 2013, OFFICAIR FIN WORKSH
  • [9] Beizaee A, 2011, PEOPLE BUILDINGS MC2
  • [10] On the interaction between lighting and thermal comfort: An integrated approach to IEQ
    Bellia, Laura
    Alfano, Francesca Romana d'Ambrosio
    Fragliasso, Francesca
    Palella, Boris Igor
    Riccio, Giuseppe
    [J]. ENERGY AND BUILDINGS, 2021, 231 (231)