Nb-content-dependent passivation behavior of Ti-Nb alloys for biomedical applications

被引:32
作者
Liu, Hao [1 ]
Wang, Ze-Xin [1 ]
Cheng, Jun [2 ]
Li, Nan [1 ]
Liang, Shun-Xing [3 ]
Zhang, Lina [1 ]
Shang, Fanmin [1 ]
Oleksandr, Dobuvyy [4 ]
Chen, Liang-Yu [1 ]
机构
[1] Jiangsu Univ Sci & Technol, Sch Mat Sci & Technol, Zhenjiang 212003, Peoples R China
[2] Northwest Inst Nonferrous Met Res, Shaanxi Key Lab Biomed Met Mat, Xian 710016, Peoples R China
[3] Guangdong Univ Technol, Sch Mat & Energy, Guangzhou 510006, Peoples R China
[4] Admiral Makarov Natl Univ, Dept Mat Sci & Technol Met, Shipbuilding Inst, UA-54025 Mykolaiv, Ukraine
来源
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T | 2023年 / 27卷
基金
中国国家自然科学基金;
关键词
Ti-Nb alloy; Microstructure; Hardness; Passivation behavior; Passive film; CORROSION BEHAVIOR; ELECTROCHEMICAL-BEHAVIOR; TI-6AL-4V ALLOY; PURE TITANIUM; NIOBIUM; FILM; SURFACE; MICROSTRUCTURE; RESISTANCE; MODULUS;
D O I
10.1016/j.jmrt.2023.11.203
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ti-Nb alloys have the advantages of non-toxicity, low elastic modulus, high strength, and good biocompatibility. However, the effect of Nb content on its passivation behavior in Hank's solution still needs to be investigated. This work investigated the microstructure, hardness, and corrosion behavior of Ti-xNb (x = 5, 15, 25 wt%) alloys. The beta phase gradually increases associated with the increasing Nb content in Ti-Nb alloys, resulting in the dispersion strengthening of alloys. Moreover, with the increased Nb content, the samples show higher open circuit potential, lower passivation current density, and higher charge transfer resistance in Hank's solution at 37 degrees C. When the passive films of Ti-Nb alloys are formed under the high potentials of 1 V and 2 V, the passive films gradually dissolve after the withdrawal of applied potential, representing the decrease in the total impedance of the passive film. The reason for this phenomenon is the addition of Nb substantially decreases the oxygen vacancies in the passive film formed on the samples. Therefore, the impedance of the passive film is increased.
引用
收藏
页码:7882 / 7894
页数:13
相关论文
共 62 条
  • [1] Microstructure and microhardness of electron beam melted Ti-6Al-4V components with differential thickness in initial deposition layers
    Abdullah, Mohammad Sayem Bin
    Bol, Eric
    Kelley, Garrett
    Doyle, Curtis
    Schleusener, Rick
    Mojib, Melody
    Chen, Xu
    Arola, Dwayne
    Ramulu, Mamidala
    [J]. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 26 : 6493 - 6507
  • [2] Comparative study on the corrosion behavior of Ti-Nb and TMA alloys for dental application in various artificial solutions
    Bai, Y. J.
    Wang, Y. B.
    Cheng, Y.
    Deng, F.
    Zheng, Y. F.
    Wei, S. C.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (03): : 702 - 711
  • [3] Characterization, corrosion behavior, cellular response and in vivo bone tissue compatibility of titanium-niobium alloy with low Young's modulus
    Bai, Yanjie
    Deng, Yi
    Zheng, Yunfei
    Li, Yongliang
    Zhang, Ranran
    Lv, Yalin
    Zhao, Qiang
    Wei, Shicheng
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 59 : 565 - 576
  • [4] Improved corrosion behaviour of electron beam melted Ti-6Al-4V alloy in phosphate buffered saline
    Bai, Yun
    Gai, Xin
    Li, Shujun
    Zhang, Lai-Chang
    Liu, Yujing
    Hao, Yulin
    Zhang, Xing
    Yang, Rui
    Gao, Yongbo
    [J]. CORROSION SCIENCE, 2017, 123 : 289 - 296
  • [5] The effect of Nb on the corrosion and hydrogen pick-up of Zr alloys
    Bell, B. D. C.
    Murphy, S. T.
    Grimes, R. W.
    Wenman, M. R.
    [J]. ACTA MATERIALIA, 2017, 132 : 425 - 431
  • [6] Passive Layers and Corrosion Resistance of Biomedical Ti-6Al-4V and β-Ti Alloys
    Bocchetta, Patrizia
    Chen, Liang-Yu
    Tardelli, Juliana Dias Corpa
    dos Reis, Andrea Candido
    Almeraya-Calderon, Facundo
    Leo, Paola
    [J]. COATINGS, 2021, 11 (05)
  • [7] Evidence of coupling between film growth and metal dissolution in passivation processes
    Bojinov, M
    Cattarin, S
    Musiani, M
    Tribollet, E
    [J]. ELECTROCHIMICA ACTA, 2003, 48 (28) : 4107 - 4117
  • [8] Electrochemical behavior of additively manufactured patterned titanium alloys under simulated normal, inflammatory, and severe inflammatory conditions
    Bordbar-Khiabani, Aydin
    Gasik, Michael
    [J]. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 26 : 356 - 370
  • [9] Degradation behavior of Ti-Nb alloys: Corrosion behavior through 21 days of immersion and tribocorrosion behavior against alumina
    Caha, I.
    Alves, A. C.
    Kuroda, P. A. B.
    Grandini, C. R.
    Pinto, A. M. P.
    Rocha, L. A.
    Toptan, F.
    [J]. CORROSION SCIENCE, 2020, 167
  • [10] Atomic-scale investigations of passive film formation on Ti-Nb alloys
    Caha, Ihsan
    Alves, Alexandra C.
    Chirico, Caterina
    Pinto, Ana Maria
    Tsipas, Sophia
    Gordo, Elena
    Bondarchuk, Oleksandr
    Deepak, Francis Leonard
    Toptan, Fatih
    [J]. APPLIED SURFACE SCIENCE, 2023, 615