The behavior of strengthened and repaired RC columns with (CFRP) rope under different preloading levels

被引:6
作者
Ashteyat, Ahmed M. [1 ]
Obaidat, Ala' Taleb [2 ,6 ]
Obaidat, Yasmeen Taleb [3 ]
Abdel-Jaber, Mu'atsem [1 ,4 ,5 ]
Al-Tarawneh, Dania [1 ]
机构
[1] Univ Jordan, Civil Engn Dept, Amman, Jordan
[2] Philadelphia Univ, Civil Engn Dept, Amman, Jordan
[3] Jordan Univ Sci & Technol, Civil Engn Dept, Irbid, Jordan
[4] Al Ahliyya Amman Univ, Fac Engn, Dept Civil Engn, Amman, Jordan
[5] Univ Jordan, Dept Civil Engn, Amman, Jordan
[6] Philadelphia Univ, Civil Engn Dept, Amman 9392, Jordan
关键词
Preloading; ropes; CFRP spacing; sheet; REINFORCED-CONCRETE COLUMNS; MOUNTED FRP REINFORCEMENT; PERFORMANCE; SHEETS;
D O I
10.1080/19648189.2023.2179668
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates impact of spacing between carbon fiber reinforced polymers (CFRP) ropes and the area of CFRP ropes on behavior of strengthened and repaired reinforced concrete (RC) circular columns that preloaded to different levels. RC columns were divided into three groups. First group (three specimens) were strengthened with NSM-CFRP rope using one layer and two layers at 100 and 200 mm spacing, whereas the second and third groups each had two columns preloaded to 50 and 75% of the control specimen's ultimate load. According to the findings, strengthening columns with one rope spaced 100 mm and two ropes spaced 200 mm enhanced ultimate load capacity by 79.7 and 14.9%, respectively, as the control column. With one rope at a spacing of 100 mm and two ropes in one groove at a spacing of 200 mm, the repaired column after 50% damage and 75% damage, respectively, achieved (114.12 and 107%) and (111.38 and 93.44%) of the ultimate load capacity. Load capacity increased as the distance between CFRP ropes decreased, resulting in a higher effective lateral confining pressure and enhanced CFRP efficacy. Finally, a good level of similarity was shown between the finite element analysis results and the test results.
引用
收藏
页码:4212 / 4236
页数:25
相关论文
共 51 条
[1]  
ACI-318, 2014, 318RM14 ACI
[2]   Experimental and analytical investigation of using externally bonded, hybrid, fiber-reinforced polymers to repair and strengthen heated, damaged RC beams in flexure [J].
Al Rjoub, Yousef ;
Obaidat, Ala ;
Ashteyat, Ahmed ;
Alshboul, Khalid .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (03) :391-417
[3]  
Alfeehan A., 2014, J ENG DEV, V18, P202
[4]   Strengthening and repair of one-way and two-way self-compacted concrete slabs using near-surface-mounted carbon-fiber-reinforced polymers [J].
Ashteyat, Ahmed M. ;
Al Rjoub, Yousef S. ;
Obaidat, Ala T. ;
Dagamseh, Huthaifah .
ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (11) :2435-2448
[5]   Compressive behaviour of concrete cylindrical FRP-confined columns subjected to a new sequential loading technique [J].
Bouchelaghem, Hafida ;
Bezazi, Abderrezak ;
Scarpa, Fabrizio .
COMPOSITES PART B-ENGINEERING, 2011, 42 (07) :1987-1993
[6]   Design strength of axially loaded RC columns strengthened by steel caging [J].
Calderon, Pedro A. ;
Adam, Jose M. ;
Ivorra, Salvador ;
Pallares, Francisco J. ;
Gimenez, Ester .
MATERIALS & DESIGN, 2009, 30 (10) :4069-4080
[7]   Investigation of a New Strengthening Technique for RC Deep Beams Using Carbon FRP Ropes as Transverse Reinforcements [J].
Chalioris, Constantin E. ;
Kosmidou, Parthena-Maria K. ;
Papadopoulos, Nikos A. .
FIBERS, 2018, 6 (03)
[8]  
Dayhim N, 2013, SCI IRAN, V20, P1361
[9]  
De Lorenzis L, 2000, ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, P521
[10]   Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures [J].
De Lorenzis, L. ;
Teng, J. G. .
COMPOSITES PART B-ENGINEERING, 2007, 38 (02) :119-143