LC and LC-MS/MS studies for identification and characterization of degradation products of d-tubocurarine chloride

被引:3
作者
Grover, Parul [1 ]
Maheshwari, Srashti [1 ]
Nagarajan, K. [1 ]
Mehta, Lovekesh [2 ,5 ]
Kumar, Sandeep [3 ]
Rastogi, Chandan [4 ]
机构
[1] KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, India
[2] Amity Univ, Amity Inst Pharm, Noida 201301, India
[3] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
[4] Vellore Inst Technol, Sch Adv Sci, Dept Chem, Vellore 632014, Tamil Nadu, India
[5] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
关键词
Characterization; Degradation pathway; Degradation products; D-Tubocurarine; HRMS; MS; Mass fragmentation pattern; PERFORMANCE LIQUID-CHROMATOGRAPHY; NEUROMUSCULAR BLOCKING-DRUGS; HUMAN-PLASMA; QUANTIFICATION; VALIDATION; ROCURONIUM; CURARE;
D O I
10.1016/j.jpba.2022.115119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Forced degradation studies of d-tubocurarine (DTC) was carried out in hydrolytic (acidic, alkaline and neutral), thermal, photolytic and oxidative degradation conditions as per International Conference on Harmonization (ICH) guideline Q1A (R2). The present study revealed that DTC is highly sensitive to oxidative degradation conditions even at room temperature whereas the drug was found to be stable in hydrolytic, photolytic and thermal stress conditions.Separation of DTC and its four degradation products (DPs) (DP-I to DP-IV) formed during stress degradation conditions were achieved on Waters Acquity CSH C18 (1.7 mu m, 2.1 mm x 100 mm) column using gradient elution with a mobile phase consisting of Eluent-A: 0.1 % Formic acid Eluent-B: acetonitrile achieved success-fully. The detection was carried out at 210 nm wavelength and the flow rate was kept at 0.3 mL/min with a 5 mu L injection volume.Also, a highly sensitive and robust HRMS/MS/TOF method was established for the identification and char-acterization of four DPs formed during the stress study. ESI +ve mode was used throughout the study for ionization of all the DPs. The degradation pathway was also established in the study that is never reported earlier.
引用
收藏
页数:14
相关论文
共 39 条
[1]   Stability indicating liquid chromatography method for the analysis of Vecuronium bromide: study of the degradation profile [J].
Abd Elrahman, Mohamed K. ;
El Houssini, Ola M. ;
Fahem, Diana K. ;
Zaazaa, Hala E. .
HELIYON, 2020, 6 (03)
[2]   Simultaneous determination of naltrexone and bupropion in their co-formulated tablet utilizing green chromatographic approach with application to human urine [J].
Abdel-Gawad, Sherif A. ;
El-Gamal, Rania M. .
SAUDI PHARMACEUTICAL JOURNAL, 2018, 26 (02) :169-176
[3]   MEASUREMENT OF D-TUBOCURARINE CHLORIDE IN HUMAN URINE USING SOLID-PHASE EXTRACTION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
ANNAN, RS ;
KIM, CS ;
MARTYN, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 526 (01) :228-234
[4]  
[Anonymous], 2005, Int Conf Harmon, V1994, P17, DOI DOI 10.1201/9781482298468
[5]  
[Anonymous], 2003, Q1A (R2), current step, V4, P1, DOI DOI 10.1136/BMJ.333.7574.873-A
[6]  
[Anonymous], 2016, T BRIT ED ENC CUR
[7]  
[Anonymous], 2006, INT C HARM TECHN REQ
[8]   DETERMINATION OF D-TUBOCURARINE CHLORIDE OR METOCURINE IODIDE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
AVRAM, MJ ;
SHANKS, CA .
JOURNAL OF CHROMATOGRAPHY, 1984, 306 (MAR) :398-404
[9]   NEWER NEUROMUSCULAR BLOCKING-AGENTS [J].
BEVAN, DR .
PHARMACOLOGY & TOXICOLOGY, 1994, 74 (01) :3-9
[10]   SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF THE NONDEPOLARIZING NEUROMUSCULAR BLOCKING-DRUGS IN CLINICAL ANESTHESIA [J].
BJORKSTEN, AR ;
BEEMER, GH ;
CRANKSHAW, DP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 533 :241-247