Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up

被引:7
作者
Niu, Erlong [1 ,2 ,4 ]
Fu, Jun [2 ,3 ]
Li, Hao [2 ,3 ]
Ni, Ming [2 ,3 ]
Hao, Libo [2 ,3 ]
Zhou, Yonggang [2 ,3 ]
Xu, Chi [2 ,3 ]
Chen, Jiying [2 ,3 ,4 ]
机构
[1] Med Sch Chinese PLA, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthoped, Beijing, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Med Ctr 4, Sr Dept Orthoped, Beijing, Peoples R China
[4] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Beijing, Peoples R China
关键词
total hip arthroplasty; ceramic-on-ceramic bearings; survivorship; clinical outcome; complication; squeaking; BONE INGROWTH; BEARING; FRACTURES; REPLACEMENT; ARTHRITIS; OUTCOMES; NOISE; WEAR;
D O I
10.1016/j.arth.2022.12.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.Methods: Among the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.Results: Survivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.Conclusion: This CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.& COPY; 2022 Published by Elsevier Inc.
引用
收藏
页码:1539 / 1544
页数:6
相关论文
共 50 条
[31]   Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study [J].
Yoo, Jun-Il ;
Ha, Yong-Chan ;
Kim, Dong-Hyun ;
Lee, Young-Kyun ;
Koo, Kyung-Hoi .
INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (05) :637-640
[32]   Cementless total hip arthroplasties using ceramic-on-ceramic articulation in young patients - A minimum 5-year follow-up study [J].
Huo, MH ;
Martin, RP ;
Zatorski, LE ;
Keggi, KJ .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :673-678
[33]   Ceramic-on-Ceramic Total Hip Arthroplasty Using a Double Tapered, Proximally Coated Stem: 15 to 24-year Clinical and Radiologic Follow-Up [J].
Darwish, Mohammad M. ;
Bergman, Neil R. ;
Hiscock, Richard J. .
JOURNAL OF ARTHROPLASTY, 2024, 39 (09) :2323-2328
[34]   Survivorship Between 2 Different Ceramic-on-Ceramic Total Hip Arthroplasty With or Without a Metal-Backed Titanium Sleeve Bearing: A 5-to 14-Year Follow-Up Study [J].
Higuchi, Yoshitoshi ;
Hasegawa, Yukiharu ;
Komatsu, Daigo ;
Seki, Taisuke ;
Ishiguro, Naoki .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :155-160
[35]   Ceramic-on-ceramic total hip arthroplasty is superior to metal-on-conventional polyethylene at 20-year follow-up: A randomised clinical trial [J].
Vendittoli, Pascal-Andre ;
Shahin, Maged ;
Riviere, Charles ;
Barry, Janie ;
Lavoie, Pauline ;
Duval, Nicolas .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
[36]   Computed Tomography Evaluation of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty With More Than 20 years of Follow-Up: Is a Follow-Up Computed Tomography Scan Necessary? [J].
Ko, Young-Seung ;
Kang, Sang Yoon ;
Kim, Hong Seok ;
Yoo, Jeong Joon .
JOURNAL OF ARTHROPLASTY, 2025, 40 (01) :144-151
[37]   Forte ceramic-on-delta ceramic cementless total hip arthroplasty: an 8-to 15-year follow-up study [J].
Moon, Jun-Ki ;
Lee, Seonjeong ;
Kim, Chul-Ho ;
Yoon, Jae Youn ;
Lee, Sunhyung ;
Lee, Kang-Sik ;
Yoon, Pil Whan .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) :5475-5483
[38]   Total hip arthroplasty in developmental hip dysplasia using cementless tapered stem. Results after a minimum 10-year follow-up [J].
Faldini, Cesare ;
Nanni, Matteo ;
Leonetti, Danilo ;
Miscione, Maria Teresa ;
Acri, Francesco ;
Giannini, Sandro .
HIP INTERNATIONAL, 2011, 21 (04) :415-420
[39]   The Ideal Total Hip Replacement Bearing Surface in the Young Patient: A Prospective Randomized Trial Comparing Alumina Ceramic-On-Ceramic With Ceramic-On-Conventional Polyethylene: 15-Year Follow-Up [J].
Atrey, Amit ;
Wolfstadt, Jesse, I ;
Hussain, Nasir ;
Khoshbin, Amir ;
Ward, Sarah ;
Shahid, Mohammad ;
Schemitsch, Emil H. ;
Waddell, James P. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (06) :1752-1756
[40]   Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants - A 12-year follow-up study [J].
Jazrawi, LM ;
Bogner, E ;
Della Valle, CJ ;
Chen, FS ;
Pak, KI ;
Stuchin, SA ;
Frankel, VH ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (07) :781-787