Immunophenotype profile by flow cytometry reveals different subtypes of extracellular vesicles in porcine seminal plasma

被引:19
作者
Barranco, Isabel [1 ]
Alvarez-Barrientos, Alberto [2 ]
Parra, Ana [1 ]
Martinez-Diaz, Pablo [1 ]
Lucas, Xiomara [1 ]
Roca, Jordi [1 ]
机构
[1] Univ Murcia, Fac Vet Sci, Dept Med & Anim Surg, Murcia, Spain
[2] Univ Extremadura, Serv Tecn Aplicadas Biociencias, Badajoz, Spain
关键词
Ejaculate; Extracellular vesicles; Flow cytometry; Pig; Seminal plasma; HSP90; SPERMATOZOA; EXPRESSION; MOTILITY; PROTEINS; EXOSOMES; BOAR;
D O I
10.1186/s12964-024-01485-1
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background Porcine seminal plasma (SP) is endowed with a heterogeneous population of extracellular vesicles (sEVs). This study evaluated the immunophenotypic profile by high-sensitivity flow cytometry of eight sEV subpopulations isolated according to their size (small [S-sEVs] and large [L-sEVs]) from four different SP sources, namely three ejaculate fractions (the first 10 mL of the sperm rich fraction [SRF-P1], the remaining SRF [SRF-P2], and the post-SRF [PSRF]) and entire ejaculate (EE). Methods Seminal EVs were isolated using a size exclusion chromatography-based protocol from six SP pools (five ejaculates/pool) of each SP source and characterized using complementary approaches including total protein (BCA (TM) assay), particle size distribution (dynamic light scattering), morphology (transmission electron microscopy), and purity (albumin by Western blot). Expression of CD9, CD63, CD81, CD44 and HSP90 beta was analyzed in all sEV subpopulations by high-sensitivity flow cytometry according to MIFlowCyt-EV guidelines, including an accurate calibration, controls, and discrimination by CFSE-labelling. Results Each sEV subpopulation exhibited a specific immunophenotypic profile. The percentage of sEVs positive for CD9, CD63, CD81 and HSP90 beta differed between S- and L-sEVs (P < 0.0001). Specifically, the percentage of sEVs positive for CD9 and CD63 was higher and that for CD81 was lower in S- than L-sEVs in the four SP sources. However, the percentage of HSP90 beta-positive sEVs was lower in S-sEVs than L-sEVs in the SRF-P1 and EE samples. The percentage of sEVs positive for CD9, CD63, and CD44 also differed among the four SP sources (P < 0.0001), being highest in PSRF samples. Notably, virtually all sEV subpopulations expressed CD44 (range: 88.04-98.50%). Conclusions This study demonstrated the utility of high-sensitivity flow cytometry for sEV immunophenotyping, allowing the identification of distinct sEV subpopulations that may have different cellular origin, cargo, functions, and target cells.
引用
收藏
页数:17
相关论文
共 50 条
[41]   Refractive index to evaluate staining specificity of extracellular vesicles by flow cytometry [J].
de Rond, L. ;
Libregts, S. F. W. M. ;
Rikkert, L. G. ;
Hau, C. M. ;
van der Pol, E. ;
Nieuwland, R. ;
van Leeuwen, T. G. ;
Coumans, F. A. W. .
JOURNAL OF EXTRACELLULAR VESICLES, 2019, 8 (01)
[42]   Protein Profiling of Malaria-Derived Extracellular Vesicles Reveals Distinct Subtypes [J].
Opadokun, Tosin ;
Agyapong, Jeffrey ;
Rohrbach, Petra .
MEMBRANES, 2022, 12 (04)
[43]   Analysis of individual extracellular vesicles by imaging flow cytometry [J].
Tertel, Tobias ;
Goergens, Andre ;
Giebel, Bernd .
EXTRACELLULAR VESICLES, 2020, 645 :55-78
[44]   Detection of extracellular vesicles in plasma and urine of prostate cancer patients by flow cytometry and surface plasmon resonance imaging [J].
Rikkert, Linda G. ;
de Rond, Leonie ;
van Dam, Annemieke ;
van Leeuwen, Ton G. ;
Coumans, Frank A. W. ;
de Reijke, Theo M. ;
Terstappen, Leon W. M. M. ;
Nieuwland, Rienk .
PLOS ONE, 2020, 15 (06)
[45]   Using Imaging Flow Cytometry to Characterize Extracellular Vesicles Isolated from Cell Culture Media, Plasma or Urine [J].
Woollard, John R. ;
Puranik, Amrutesh ;
Jordan, Kyra L. ;
Lerman, Lilach O. .
BIO-PROTOCOL, 2019, 9 (21)
[46]   Untargeted Metabolomic Profiling of Extracellular Vesicles Isolated from Human Seminal Plasma [J].
Selvam, Manesh Kumar Panner ;
Chandra, Partha K. ;
Bakhtiary, Zahra ;
Busija, David W. ;
Sikka, Suresh C. .
BIOMOLECULES, 2024, 14 (10)
[47]   Protein Profiling and Sizing of Extracellular Vesicles from Colorectal Cancer Patients via Flow Cytometry [J].
Tian, Ye ;
Ma, Ling ;
Gong, Manfei ;
Su, Guoqiang ;
Zhu, Shaobin ;
Zhang, Wenqiang ;
Wang, Shuo ;
Li, Zhibin ;
Chen, Chaoxiang ;
Li, Lihong ;
Wu, Lina ;
Yan, Xiaomei .
ACS NANO, 2018, 12 (01) :671-680
[48]   A bead-assisted flow cytometry method for the semi-quantitative analysis of Extracellular Vesicles [J].
Suarez, Henar ;
Gomez-Valero, Ana ;
Reyes, Raquel ;
Lopez-Martin, Soraya ;
Josefa Rodriguez, Maria ;
Carrascosa, Jose L. ;
Cabanas, Carlos ;
Borras, Francesc E. ;
Yanez-Mo, Maria .
SCIENTIFIC REPORTS, 2017, 7
[49]   Conventional, High-Resolution and Imaging Flow Cytometry: Benchmarking Performance in Characterisation of Extracellular Vesicles [J].
Botha, Jaco ;
Pugsley, Haley R. ;
Handberg, Aase .
BIOMEDICINES, 2021, 9 (02) :1-24
[50]   Antibody-Free Labeling of Malaria-Derived Extracellular Vesicles Using Flow Cytometry [J].
Dekel, Elya ;
Abou Karam, Paula ;
Ohana-Daniel, Yael ;
Biton, Mirit ;
Regev-Rudzki, Neta ;
Porat, Ziv .
BIOMEDICINES, 2020, 8 (05)