Measurement of the retinal venous pressure with a new instrument in patients with primary open angle glaucoma

被引:0
作者
Stodtmeister, Richard [1 ]
Menzel, Aline [1 ]
Klimova, Anna [2 ,3 ]
Herber, Robert [1 ]
Pillunat, Karin. R. [1 ]
Pillunat, Lutz E. [1 ]
机构
[1] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Ophthalmol, Fetscherstr 74, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Natl Ctr Tumor Dis NCT UCC, German Canc Res Ctr DKFZ, Fac Med,Helmholtz Zent Dresden Rossendorf HZDR, D-01307 Dresden, Germany
[3] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Helmholtz Zent Dresden Rossendorf HZDR, D-01307 Dresden, Germany
关键词
Retinal veins; Venous pressure; Ocular circulation; Intraocular pressure; Ophthalmodynamometry; Data accuracy; GOLDMANN APPLANATION TONOMETRY; STATISTICAL-METHODS; PULSATION; CALIBRATION; AGREEMENT; ICARE;
D O I
10.1007/s00417-023-06326-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo compare the results of retinal venous pressure (RVP) measurement performed with contact lens dynamometry (CLD) and with the new IOPstim.MethodsIn this cross-sectional study, we included 36 patients with primary open angle glaucoma with a median age (Q25; Q75) of 74 (64; 77) years (m/f = 18/18), baseline intraocular pressure (IOP): 13.9 (12.2; 15.1) mmHg. Median mean defect: - 5.8 (- 11.9; - 2.6) db. Principle of the IOPstim: an empty balloon with a diameter of 8 mm is positioned on the eye, laterally of the limbus. Under observation of the central retinal vein (CRV), the examiner inflates the balloon. As soon as the CRV starts pulsation, the inflation is stopped and the IOP is measured, equaling the RVP at this moment. In the CLD, the pulsation of the CRV is observed with a contact lens. The RVP is calculated from the attachment force applied when pulsation appears.Course of examinationsThree single measurements of RVP in quick succession with both methods. The sequence of the two methods was randomized. The means of the three RVP measurements were compared.ResultsPressures in mmHg. RVP: IOPstim: 19.4 +/- 5.4 (mean +/- SD), CLD: 20.3 +/- 5.9. Range of three single measurements: IOPstim: 2.9 +/- 1.5, CLD: 2.2 +/- 1.1. The differences were RVPIOPstim - RVPCLD = - 0.94 +/- 1.15, and approximately normally distributed. Bland-Altman analysis: only one data point was 0.5 mmHg higher than the upper line of agreement. The confidence interval of this line was 0.65 mmHg. Concordance correlation coefficient according to Lin (CCC): 0.96. Intraclass correlation coefficient: both methods, 0.94.ConclusionIn both methods, the range of the single measurements may be taken as a sign of good reliability, the CCC of 0.96 as a sign of a very good agreement. At the mean, the IOPstim RVP values were 1 mmHg lower than those obtained with the CLD. This difference may be due to the different directions of the prevailing force vectors induced by the instruments. The IOPstim seems applicable in glaucoma diagnostics.
引用
收藏
页码:1633 / 1639
页数:7
相关论文
共 50 条
  • [21] Trabeculectomy Ab Interno in Primary Open Angle Glaucoma and Exfoliative Glaucoma
    Pahlitzsch, M.
    Gonnermann, J.
    Maier, A-K. B.
    Torun, N.
    Bertelmann, E.
    Joussen, A. M.
    Klamann, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (10) : 1198 - 1207
  • [22] Intraocular pressure in the Beninese:: screening for primary open-angle glaucoma
    Tchabi, S
    Doutétien, C
    Amoussouga, A
    Babagbéto, M
    Lawani, R
    Déguénon, J
    Bassabi, SK
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (06): : 623 - 626
  • [23] Electrophysiological evaluation and visual outcome in patients with central retinal vein occlusion, primary open-angle glaucoma and neovascular glaucoma
    Wittstrom, Elisabeth
    Ponjavic, Vesna
    Lovestam-Adrian, Monica
    Larsson, Joergen
    Andreasson, Sten
    ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 86 - 90
  • [24] Aspects of Tertiary Prevention in Patients with Primary Open Angle Glaucoma
    Munteanu, Gabriel Zeno
    Munteanu, Zeno Virgiliu Ioan
    Roiu, George
    Daina, Cristian Marius
    Moraru, Raluca
    Moraru, Liviu
    Trambitas, Cristian
    Badau, Dana
    Daina, Lucia Georgeta
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (09):
  • [25] Primary Open-Angle Glaucoma
    Sharts-Hopko, Nancy C.
    Glynn-Milley, Catherine
    AMERICAN JOURNAL OF NURSING, 2009, 109 (02) : 40 - 47
  • [26] Hypertension in Primary Open Angle Glaucoma
    Pokharel, Suprada
    Sherpa, Dakki
    Malla, Om Krishna
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2014, 52 (10) : 766 - 769
  • [27] Primary open angle glaucoma and hypothyroidism
    Kitsos, George
    Pappa, Chrisavgi
    Tsatsoulis, Agathoklis
    CLINICAL OPTOMETRY, 2010, 2 : 5 - 8
  • [28] Hypotensive therapy in patients with primary open-angle glaucoma
    Krasinska, Beata
    Kociecki, Jaroslaw
    Krasinski, Zbigniew
    Tykarski, Andrzej
    KARDIOLOGIA POLSKA, 2013, 71 (08) : 869 - 874
  • [29] Biomarkers in primary open angle glaucoma
    Kokotas, Haris
    Kroupis, Christos
    Chiras, Dimitrios
    Grigoriadou, Maria
    Lamnissou, Klea
    Petersen, Michael B.
    Kitsos, George
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (12) : 2107 - 2119
  • [30] Primary open-angle glaucoma
    Bertaud, S.
    Aragno, V
    Baudouin, C.
    Labbe, A.
    REVUE DE MEDECINE INTERNE, 2019, 40 (07): : 445 - 452