Numerical study of the fire behaviour of external walls in light steel framing

被引:0
|
作者
Torres, Leonardo [1 ]
Couto, Carlos [1 ,3 ]
Real, Paulo Vila [1 ]
Piloto, Paulo [2 ]
机构
[1] Univ Aveiro, Dept Civil Engn, RISCO, Aveiro, Portugal
[2] Inst Politecn Braganca, LAETA INEGI, Braganca, Portugal
[3] Campus Univ Santiago, P-3810193 Aveiro, Portugal
关键词
Light steel framing; External walls; Numerical simulation; Fire resistance; Fire behaviour; COLD-FORMED STEEL; GYPSUM BOARD; THERMAL PERFORMANCE; COMPOSITE PANELS; DESIGN RULES; RESISTANCE; SYSTEMS; TEMPERATURE; PLASTERBOARDS; CONSTRUCTION;
D O I
10.1016/j.firesaf.2023.103946
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study focuses on the fire behaviour of external walls in Light Steel Frame (LSF) structures. Previous investigations have primarily addressed the fire behaviour of internal wall configurations, however, the increasing number of fires affecting external walls shows that their behaviour must also be understood. Therefore, this work investigates the fire behaviour of these elements, presenting a numerical study of six different typologies usually found in LSF practice by analysing the temperature evolution across the wall and in the steel profiles. The results show that the temperature evolution is slower when the fire is impacting the outer side of the wall but, in these cases, the recommended critical temperature of 350 degrees C is reached earlier in the steel profiles. Finally, this work shows that more studies are necessary to describe the fire resistance of external walls, in particular when these elements have a loadbearing function.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] FIRE PERFORMANCE OF NON-LOADBEARING LIGHT STEEL FRAMING WALLS - NUMERICAL SIMULATION
    Piloto, Paulo A. G.
    Khetata, Mohamed S.
    Gavilan, Ana B. R.
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN (M2D2017), 2017, : 1603 - 1610
  • [2] Fire resistance of composite non-load bearing light steel framing walls
    Khetata, Seddik M.
    Piloto, Paulo A. G.
    Gavilan, Ana B. R.
    JOURNAL OF FIRE SCIENCES, 2020, 38 (02) : 136 - 155
  • [3] Numerical thermal performance analysis of light steel insulated walls under fire
    Hassoune, Mohammed
    Kada, Abdelhak
    Menadi, Belkacem
    Lamri, Belkacem
    GRADEVNSKI MATERIJIALI I KONSTRUKCIJE-BUILDING MATERIALS AND STRUCTURES, 2023, 66 (01): : 43 - 54
  • [4] Fire resistance of external light gauge steel framed walls with brick veneer cladding
    Pancheti, Jashnav
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2023, 182
  • [5] Experimental and numerical assessment of the behaviour of external heavy steel columns under natural fire
    C.T.I.C.M., Saint Remy-Les-Chevreuse, France
    Journal of Constructional Steel Research, 1998, 46 (1-3): : 300 - 301
  • [6] Fire resistance of external LSF walls with corrugated steel cladding
    Pancheti, Jashnav
    Mahendran, Mahen
    Steau, Edward
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 188
  • [7] Experimental study of light gauge steel framing floor systems under fire conditions
    Baleshan, Balachandren
    Mahendran, Mahen
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (03) : 426 - 445
  • [8] Fire resistance of external light gauge steel framed walls clad with autoclaved aerated concrete panels
    Pancheti, Jashnav
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2021, 167
  • [9] Experimental Investigation of Light Steel Framing Walls under Horizontal Loading
    Lopes, Dalila M.
    Duarte, Antonio P. C.
    Silvestre, Nuno
    BUILDINGS, 2023, 13 (01)
  • [10] Fire performance enhancement of cold-formed steel walls: experimental and numerical study
    Liu, Kang
    Chen, Wei
    Ye, Jihong
    Jiang, Jian
    Fang, Zhiyuan
    ENGINEERING STRUCTURES, 2024, 314