Robust Analog Multisensory Array System for Lossy Capacitive Sensors Over Long Distances

被引:12
作者
Kapic, Amar [1 ,2 ]
Tsirou, Andromachi [2 ]
Verdini, Piero Giorgio [3 ]
Carrara, Sandro [1 ]
机构
[1] Ecole Polytech Fed Lausanne EPFL, EPFL STI IMT ICLAB MC A3 Microcity 194, Rue Maladiere 71b, CH-2002 Neuchatel, Switzerland
[2] European Lab Nucl Res CERN, CH-1211 Geneva, Switzerland
[3] INFN, Sez Pisa, I-56127 Pisa, Italy
关键词
Sensors; Capacitive sensors; Detectors; Humidity; Bridge circuits; Temperature sensors; Coaxial cables; Auto-balancing bridge; coaxial cables; High-Energy Physics (HEP) detectors; leakage resistance; lossy capacitive sensors; parasitic capacitance; quadrature-phase shifter; relative humidity; INTERFACE CIRCUIT; PRECISION;
D O I
10.1109/TIM.2022.3225041
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A robust capacitive multisensory readout system is presented in this article. The system consists of a few thousand lossy capacitive-based sensors that can be modeled as a parallel connection of sensor capacitor and undesirable leakage resistance. The real system in our application will consist of a high number of capacitive sensors used for the monitoring of relative humidity in a high-energy detector at the European Organization for Nuclear Research (CERN). However, our findings apply to any set of capacitive devices aimed at any other sensing application. Furthermore, the proposed system is intended for harsh environments (e.g., with high radiation levels and magnetic field presence) where the readout system is separated from the sensor and placed far away, connecting to them via cables. In such cases, the presence of cables brings another issue to the readout system-parasitic capacitance. Using long cables, we introduce high values of parasitic capacitance that make the sensor capacitance practically invisible to the readout unit. This article presents an effective, robust, and analog method, based on a quadrature-phase shifter and an auto-balancing bridge, used to overcome the sensor leakage resistance and parasitic capacitance caused by the cables. The experiments for various values of capacitance and leakage resistance at different frequencies and the influence of different cable lengths and types are analyzed and discussed.
引用
收藏
页数:8
相关论文
共 36 条
[1]  
ATLAS Collaboration, 1999, CERNLHCC9915 ATLAS C
[2]  
Baxter L.K., 1996, CAPACITIVE SENSORS D
[3]   A semicylindrical capacitive sensor with interface circuit used for flow rate measurement [J].
Chiang, Cheng-Ta ;
Huang, Yu-Chung .
IEEE SENSORS JOURNAL, 2006, 6 (06) :1564-1570
[4]  
CMS Collaboration, 2006, 2006001 CERNLHCC CMS
[5]   A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit [J].
Czaja, Zbigniew .
MEASUREMENT, 2021, 170
[6]  
Datasheet, DAT MK33 CAP HUM SEN
[7]   Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review [J].
Farahani, Hamid ;
Wagiran, Rahman ;
Hamidon, Mohd Nizar .
SENSORS, 2014, 14 (05) :7881-7939
[8]  
Fraden J., 2016, Handbook of Modern Sensors, pChapter 2
[9]   Piezoelectric vs. Capacitive Based Force Sensing in Capacitive Touch Panels [J].
Gao, Shuo ;
Arcos, Victor ;
Nathan, Arokia .
IEEE ACCESS, 2016, 4 :3769-3774
[10]   Anodized Aluminum Oxide-Assisted Low-Cost Flexible Capacitive Pressure Sensors Based on Double-Sided Nanopillars by a Facile Fabrication Method [J].
Guo, Yunjian ;
Gao, Song ;
Yue, Wenjing ;
Zhang, Chunwei ;
Li, Yang .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (51) :48594-48603