Automated planning of stereotactic spine re-irradiation using cumulative dose limits

被引:4
作者
Meyer, Sebastian [1 ,3 ]
Zhang, Lei [1 ]
Liu, Yilin [1 ]
Kuo, Li Cheng [1 ]
Yamada, Yoshiya [2 ]
Zarepisheh, Masoud [1 ]
Zhang, Pengpeng [1 ]
Cervin, Laura [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY USA
[3] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 29卷
关键词
Re-irradiation; Spine SBRT; Automated planning; BODY RADIATION-THERAPY; DEFINITION; MANAGEMENT; TOLERANCE; CONSENSUS;
D O I
10.1016/j.phro.2024.100547
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: The lack of dedicated tools in commercial planning systems currently restricts efficient review and planning for re-irradiation. The aim of this study was to develop an automated re-irradiation planning framework based on cumulative doses. Materials and Methods: We performed a retrospective study of 14 patients who received spine SBRT re-irradiation near a previously irradiated treatment site. A fully-automated workflow, DART (Dose Accumulation-based Re-irradiation Tool), was implemented within Eclipse by leveraging a combination of a dose accumulation script and a proprietary automated optimization algorithm. First, we converted the prior treatment dose into equivalent dose in 2 Gy fractions (EQD2) and mapped it to the current anatomy, utilizing deformable image registration. Subsequently, the intersection of EQD2 isodose lines with relevant organs at risk defines a series of optimization structures. During plan optimization, the residual allowable dose at a specified tissue tolerance was treated as a hard constraint. Results: All DART plans met institutional physical and cumulative constraints and passed plan checks by qualified medical physicists. DART demonstrated significant improvements in target coverage over clinical plans, with an average increase in PTV D-99% and V-100% of 2.3 Gy [range -0.3-7.7 Gy] and 3.4 % [range -0.4 %-7.6 %] (p < 0.01, paired t-test), respectively. Moreover, high-dose spillage (>105 %) outside the PTV was reduced by up to 7 cm(3). The homogeneity index for DART plans was improved by 19 % (p < 0.001). Conclusions: DART provides a powerful framework to achieve more tailored re-irradiation plans by accounting for dose distributions from the previous treatments. The superior plan quality could improve the therapeutic ratio for re-irradiation patients. Results: All DART plans met institutional physical and cumulative constraints and passed plan checks by qualified medical physicists. DART demonstrated significant improvements in target coverage over clinical plans, with an average increase in PTV D99% and V100% of 2.3 Gy [range - 0.3-7.7 Gy] and 3.4 % [range -0.4 %-7.6 %] (p < 0.01, paired t-test), respectively. Moreover, high-dose spillage (>105 %) outside the PTV was reduced by up to 7 cm3. The homogeneity index for DART plans was improved by 19 % (p < 0.001). Conclusions: DART provides a powerful framework to achieve more tailored re-irradiation plans by accounting for dose distributions from the previous treatments. The superior plan quality could improve the therapeutic ratio for re-irradiation patients.
引用
收藏
页数:6
相关论文
共 29 条
[1]  
Andratschke N, 2022, LANCET ONCOL, V23, pE469, DOI 10.1016/S1470-2045(22)00447-8
[2]   Deformable Registration for Dose Accumulation [J].
Chetty, Indrin J. ;
Rosu-Bubulac, Mihaela .
SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) :198-208
[3]   International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery [J].
Cox, Brett W. ;
Spratt, Daniel E. ;
Lovelock, Michael ;
Bilsky, Mark H. ;
Lis, Eric ;
Ryu, Samuel ;
Sheehan, Jason ;
Gerszten, Peter C. ;
Chang, Eric ;
Gibbs, Iris ;
Soltys, Scott ;
Sahgal, Arjun ;
Deasy, Joe ;
Flickinger, John ;
Quader, Mubina ;
Mindea, Stefan ;
Yamada, Yoshiya .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05) :E597-E605
[4]   New clinical data on human spinal cord re-irradiation tolerance [J].
Doi, Hiroshi ;
Tamari, Keisuke ;
Oh, Ryoong-Jin ;
Nieder, Carsten .
STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (06) :463-473
[5]   Clinical Experience of Automated SBRT Paraspinal and Other Metastatic Tumor Planning With Constrained Hierarchical Optimization [J].
Hong, Linda ;
Zhou, Ying ;
Yang, Jie ;
Mechalakos, James G. ;
Hunt, Margie A. ;
Mageras, Gig S. ;
Yang, Jonathan ;
Yamada, Josh ;
Deasy, Joseph O. ;
Zarepisheh, Masoud .
ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (05) :1042-1050
[6]  
Hu Y, 2021, Med Phys, V48, pe117, DOI [10.1002/mp.15041, DOI 10.1002/MP.15041]
[7]   Optimization of re-irradiation using deformable registration: a case study [J].
Jumeau, Raphael ;
Peguret, Nicolas ;
Zulliger, Cedric ;
Moeckli, Raphael ;
Bourhis, Jean ;
Ozsahin, Esat-Mahmut .
BJR CASE REPORTS, 2016, 2 (02)
[8]   Surgical management of spinal metastases [J].
Klimo, P ;
Schmidt, MH .
ONCOLOGIST, 2004, 9 (02) :188-196
[9]   Management of recurrent or progressive spinal metastases: reirradiation techniques and surgical principles [J].
Kotecha, Rupesh ;
Dea, Nicolas ;
Detsky, Jay S. ;
Sahgal, Arjun .
NEURO-ONCOLOGY PRACTICE, 2020, 7 :45-53
[10]   CORRELATION OF LOCAL FAILURE WITH MEASURES OF DOSE INSUFFICIENCY IN THE HIGH-DOSE SINGLE-FRACTION TREATMENT OF BONY METASTASES [J].
Lovelock, D. Michael ;
Zhang, Zhigang ;
Jackson, Andrew ;
Keam, Jennifer ;
Bekelman, Justin ;
Bilsky, Mark ;
Lis, Eric ;
Yamada, Yoshiya .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04) :1282-1287