Flow diversion: a disruptive technology coming of age. Lessons learned and challenges for the future

被引:22
作者
Enriquez-Marulanda, Alejandro [1 ]
Young, Michael M. [1 ]
Taussky, Philipp [1 ,2 ]
机构
[1] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Neurosurg Serv, Boston, MA USA
[2] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
关键词
intracranial aneurysm; embolization; flow diversion; stent; vascular disorders; PIPELINE EMBOLIZATION DEVICE; INTERNAL CAROTID-ARTERY; UNRUPTURED INTRACRANIAL ANEURYSMS; POSTERIOR COMMUNICATING ARTERY; SINGLE-CENTER EXPERIENCE; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; FOLLOW-UP; DIVERTORS; RECONSTRUCTION;
D O I
10.3171/2023.3.JNS221795
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Intracranial aneurysm treatment has been revolutionized over the last decade with the development of flow diversion technology. The use of this technology has evolved rapidly and has proven that cerebrovascular disease treatment remains one of the forefront innovation areas in neurosurgery. The good results on the treatment of internal carotid artery aneurysms up to the communicating segment have motivated the use of flow diversion beyond the circle of Willis and in the posterior circulation. Further advances and innovations of flow-diverting devices are underway and intended to improve the safety and efficacy of this therapy. This review article provides a detailed discussion about the origin, mechanism of action, initial experience, complications, types of devices, and future perspectives of flow diversion technology.
引用
收藏
页码:1317 / 1327
页数:11
相关论文
共 100 条
[51]   Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check [J].
Jou, Liang-Der ;
Chintalapani, Gouthami ;
Mawad, Michel E. .
INTERVENTIONAL NEURORADIOLOGY, 2016, 22 (01) :42-48
[52]   International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment Study [J].
Kallmes, D. F. ;
Hanel, R. ;
Lopes, D. ;
Boccardi, E. ;
Bonafe, A. ;
Cekirge, S. ;
Fiorella, D. ;
Jabbour, P. ;
Levy, E. ;
McDougall, C. ;
Siddiqui, A. ;
Szikora, I. ;
Woo, H. ;
Albuquerque, F. ;
Bozorgchami, H. ;
Dashti, S. R. ;
Almandoz, J. E. Delgado ;
Kelly, M. E. ;
Turner, R. ;
Woodward, B. K. ;
Brinjikji, W. ;
Lanzino, G. ;
Lylyk, P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (01) :108-115
[53]   A new endoluminal, flow-disrupting device for treatment of saccular aneurysms [J].
Kallmes, David F. ;
Ding, Yong Hong ;
Dai, Daying ;
Kadirvel, Ramanathan ;
Lewis, Debra A. ;
Cloft, Harry J. .
STROKE, 2007, 38 (08) :2346-2352
[54]   Aneurysm Study of Pipeline in an Observational Registry (ASPIRe) [J].
Kallmes, David F. ;
Brinjikji, Waleed ;
Boccardi, Edoardo ;
Ciceri, Elisa ;
Diaz, Orlando ;
Tawk, Rabih ;
Woo, Henry ;
Jabbour, Pascal ;
Albuquerque, Felipe ;
Chapot, Rene ;
Bonafe, Alain ;
Dashti, Shervin R. ;
Almandoz, Josser E. Delgado ;
Given, Curtis, II ;
Kelly, Michael E. ;
Cross, DeWitte T., III ;
Duckwiler, Gary ;
Razack, Nasser ;
Powers, Ciaran J. ;
Fischer, Sebastian ;
Lopes, Demetrius ;
Harrigan, Mark R. ;
Huddle, Daniel ;
Turner, Raymond ;
Zaidat, Osama O. ;
Defreyne, Luc ;
Pereira, Vitor Mendes ;
Cekirge, Saruhan ;
Fiorella, David ;
Hanel, Ricardo A. ;
Lylyk, Pedro ;
McDougall, Cameron ;
Siddiqui, Adnan ;
Szikora, Istvan ;
Levy, Elad .
INTERVENTIONAL NEUROLOGY, 2016, 5 (1-2) :89-99
[55]   Aneurysms with persistent patency after treatment with the Pipeline Embolization Device [J].
Kan, Peter ;
Srinivasan, Visish M. ;
Mbabuike, Nnenna ;
Tawk, Rabih G. ;
Ban, Vin Shen ;
Welch, Babu G. ;
Mokin, Maxim ;
Mitchell, Bartley D. ;
Puri, Ajit ;
Binning, Mandy J. ;
Duckworth, Edward .
JOURNAL OF NEUROSURGERY, 2017, 126 (06) :1894-1898
[56]   Treatment failure of fetal posterior communicating artery aneurysms with the pipeline embolization device [J].
Kan, Peter ;
Duckworth, Edward ;
Puri, Ajit ;
Velat, Greg ;
Wakhloo, Ajay .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (09) :945-948
[57]  
Kim Byung Moon, 2016, Neurointervention, V11, P10, DOI 10.5469/neuroint.2016.11.1.10
[58]   Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment [J].
Kulcsar, Z. ;
Houdart, E. ;
Bonafe, A. ;
Parker, G. ;
Millar, J. ;
Goddard, A. J. P. ;
Renowden, S. ;
Gal, G. ;
Turowski, B. ;
Mitchell, K. ;
Gray, F. ;
Rodriguez, M. ;
van den Berg, R. ;
Gruber, A. ;
Desal, H. ;
Wanke, I. ;
Ruefenacht, D. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :20-25
[59]   Use of Pipeline Flex is associated with reduced fluoroscopy time, procedure time, and technical failure compared with the first-generation Pipeline embolization device [J].
Le, Elizabeth J. ;
Miller, Timothy ;
Serulle, Yafell ;
Shivashankar, Ravishankar ;
Jindal, Gaurav ;
Gandhi, Dheeraj .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (02) :188-U62
[60]   Imbalanced flow changes of distal arteries: An important factor in process of delayed ipsilateral parenchymal hemorrhage after flow diversion in patients with cerebral aneurysms [J].
Li, Wenqiang ;
Zhu, Wei ;
Liu, Jian ;
Yang, Xinjian .
INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (06) :788-797