Determination of Metals by Portable Millisecond Pulsed Solution Cathode Glow Discharge (SCGD) Atomic Emission Spectroscopy (AES)

被引:2
作者
Zheng, Peichao [1 ]
Wang, Ningshen [1 ]
Wang, Jinmei [1 ]
Qazi, Hafiz Imran Ahmad [1 ]
Tian, Hongwu [2 ]
Dong, Daming [2 ]
He, Yuxin [1 ]
Wu, Meini [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing Municipal Level Key Lab Photoelect Infor, Chongqing, Peoples R China
[2] Beijing Acad Agr & Forestry Sci, Natl Res Ctr Intelligent Equipment Agr, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry (AES); elemental analysis; millisecond pulsed solution cathode glow discharge (SCGD); solution spectroscopy; OPTICAL-EMISSION; ELEMENTAL ANALYSIS; SPECTROMETRY; WATER; SAMPLES; CONTACT; COMPACT;
D O I
10.1080/00032719.2023.2231110
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to determine metal ions in aqueous solution, a millisecond pulsed solution cathode glow discharge (SCGD) source coupled with a portable spectrometer was developed for atomic emission spectrometry (AES). The millisecond pulsed SCGD source was operated with two high-voltage DC power supplies and a high-voltage pulse switch, specifically boosting the analyte excitation and sustain the glow discharge. The method to excite the plasma discharge contrasts with traditional approaches that employ a single power source. The influence of operating parameters, including pulsed voltage, pulsed frequency, duty ratio, and sample flow rate, were optimized to construct a system having good stability and improved excitation of metal ions. The optimum detection limits for Na, K, Li, Mg, Ag, Cs, Rb, and Sr were 0.17, 0.32, 0.38, 0.50, 2.65, 1.30, 0.22, and 74.02 & mu;g & BULL;L-1, respectively. Furthermore, mountain spring, Yangtze River, and reservoir water were spiked with Ag, Rb, and Cs; the recoveries ranged from 105% to 106%, 106% to 107%, and 107% to 108% indicating that the developed system has favorable analytical performance.
引用
收藏
页码:855 / 865
页数:11
相关论文
共 25 条
  • [1] Effects of storage time and temperature on the antimony and some trace element release from polyethylene terephthalate (PET) into the bottled drinking water
    Aghaee, Ebrahim Molaee
    Alimohammadi, Mahmood
    Nabizadeh, Ramin
    Khaniki, Gholamreza Jahed
    Naseri, Simin
    Mahvi, Amir Hossein
    Yaghmaeian, Kamyar
    Aslani, Hassan
    Nazmara, Shahrokh
    Mahmoudi, Babak
    Ghani, Maryam
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [2] Determination of zinc in edible oils by flow injection FAAS after extraction induced by emulsion breaking procedure
    Bakircioglu, Dilek
    Topraksever, Nukte
    Kurtulus, Yasemin Bakircioglu
    [J]. FOOD CHEMISTRY, 2014, 151 : 219 - 224
  • [3] DIRECT SOLUTION ANALYSIS BY GLOW-DISCHARGE - ELECTROLYTE-CATHODE DISCHARGE SPECTROMETRY
    CSERFALVI, T
    MEZEI, P
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) : 345 - 349
  • [4] EMISSION STUDIES ON A GLOW-DISCHARGE IN ATMOSPHERIC-PRESSURE AIR USING WATER AS A CATHODE
    CSERFALVI, T
    MEZEI, P
    APAI, P
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (12) : 2184 - 2188
  • [5] Role of powering geometries and sheath gas composition on operation characteristics and the optical emission in the liquid sampling-atmospheric pressure glow discharge
    Davis, WC
    Marcus, RK
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (09) : 1473 - 1486
  • [6] Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide
    Divrikli, Ü
    Elçi, L
    [J]. ANALYTICA CHIMICA ACTA, 2002, 452 (02) : 231 - 235
  • [7] Reduction of spectral interferences in atmospheric pressure glow discharge optical emission spectrometry
    Greda, Krzysztof
    Swiderski, Krzysztof
    Jamroz, Piotr
    Pohl, Pawel
    [J]. MICROCHEMICAL JOURNAL, 2017, 130 : 7 - 13
  • [8] An analytical performance of atmospheric pressure glow discharge generated in contact with flowing small size liquid cathode
    Jamroz, Piotr
    Pohl, Pawel
    Zyrnicki, Wieslaw
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (06) : 1032 - 1037
  • [9] Separation and preconcentration of aluminum in parenteral solutions and bottled mineral water using different analytical techniques
    Kazi, Tasneem G.
    Khan, Sumaira
    Baig, Jameel A.
    Kolachi, Nida F.
    Afridi, Hassan I.
    Kandhro, Ghulam A.
    Kumar, Sham
    Shah, Abdul Q.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 172 (2-3) : 780 - 785
  • [10] An atmospheric pressure glow discharge optical emission source for the direct sampling of liquid media
    Marcus, RK
    Davis, WC
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2903 - 2910