Migration of a Kirschner Wire Into the Urinary Bladder: A Case Report

被引:0
|
作者
Farion, Aleksei O. [1 ]
Paskov, Roman V. [1 ,2 ]
Dushin, Denis V. [2 ]
Bazarov, Alexander Yu. [1 ]
Prokopev, Aleksey N. [1 ]
机构
[1] Tyumen Reg Hosp 2, Tumen, Russia
[2] Tetyukhin Ural Clin Ctr Treatment & Rehabil, Nizhny Tagil, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2023年 / 29卷 / 02期
关键词
femoral neck osteosynthesis; Kirschner wires; migration of wires; pseudoarthrosis of the femoral neck; ACROMIOCLAVICULAR JOINT; FIXATION; PIN;
D O I
10.17816/2311-2905-6610
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Migration of Kirschner wires is a dangerous complication of osteosynthesis, especially when they displace into adjacent anatomical areas. Preventive measures do not eliminate the possibility of this complication.Aim of the study - to draw physicians' attention to the possibility of asymptomatic migration of a Kirschner wire into the bladder after osteosynthesis of a femoral neck fracture with a bundle of wiresCase presentation. We present a case report of a 70-year-old patient with asymptomatic migration of Kirschner wires into the bladder and hip joint cavity, which occurred 5 years after the primary surgery for the fracture of the left femoral neck. To manage the complication, a combination of endoscopic removal of the foreign body from the bladder and open removal from the hip joint followed by total hip replacement were used simultaneously. The surgical intervention was performed without any complications. The patient began rehabilitation the next day after the surgery.Conclusion. Osteosynthesis should be supplemented with preventive measures against the fracture of fixator and its migration. The patient must be dynamically followed up during the treatment period with all necessary monitoring methods (X-ray, CT scan, ultrasound, etc.). In case of wire fracture and/or migration, it must be removed immediately. Once the fracture has healed or the period of fixation of the dislocation is over, the wires should also be removed. Preventive measures can avoid the migration of Kirschner wires and related complications.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 50 条
  • [21] Technique and biomechanics of Kirschner wire osteosynthesis in children
    Slongo, Theddy
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2020, 32 (06): : 509 - 529
  • [22] The Novel Hooked Kirschner Wire Technique for Ulna Coronoid Process Fractures
    Jo, Seong-Woo
    Shin, Dong-Ju
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (01) : 127 - 134
  • [23] K wire migration into spinal canal: an infrequent cause of neurological morbidity - a case report
    Bhattarai, Ashbin
    Gurung, Bijaya
    Sherchan, Binod
    Rijal, Badri
    Karki, Prasanna D.
    ANNALS OF MEDICINE AND SURGERY, 2024, 86 (12): : 7431 - 7435
  • [24] Kirschner wire fixation for scaphoid fractures: an experimental study in synthetic bones
    Gokce, V.
    Oflaz, H.
    Dulgeroglu, A.
    Bora, A.
    Gunal, I.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (04) : 325 - 328
  • [25] Kirschner Wire Exposure in Hand and Wrist Trauma
    Henry, Mark H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2063 - 2064
  • [26] Restoration of the impacted nasal pyramid using a Kirschner wire
    Murphy, J
    Marshall, AH
    Jones, NS
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2004, 118 (07) : 543 - 545
  • [27] Laparoscopic extraction of fractured Kirschner wire from the pelvis
    Thati, Vinaykumar N.
    Kamat, Manmohan M.
    Khandelwal, Nidhi K.
    JOURNAL OF MINIMAL ACCESS SURGERY, 2014, 10 (02) : 97 - 98
  • [28] Intramedullary Screw and Kirschner Wire Fixation for Unstable Scaphoid Nonunion
    Allon, Raviv
    Kramer, Aviv
    Wollstein, Ronit
    JOURNAL OF HAND AND MICROSURGERY, 2016, 8 (03) : 150 - 154
  • [29] Anatomic Basis of Percutaneous Kirschner Wire Insertion in Zygoma Fractures
    Comert, Ela
    Comert, Ayhan
    Uz, Aysun
    Tuncel, Umit
    Elhan, Alaittin
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (04) : 1483 - 1485
  • [30] Use of sutures as Kirschner wire and tension-band wire for olecranon fractures: a technical note
    Henseler, J. F.
    van der Zwaal, P.
    Dijkstra, P. D. S.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 440 - 442